Altronix WAYPOINT30ADU Installation Instructions

AC Outdoor Power Supplies
Installation Guide
Models Include:
WayPoint30ADU
- 24VAC @ 12.5 amp and/or 28VAC @ 10 amp.
- Two (2) PTC protected outputs.
WayPoint30A4U WayPoint30A4DU
- 24VAC @ 12.5 amp or 28VAC @ 10 amp. - 24VAC @ 12.5 amp or 28VAC @ 10 amp.
WayPoint30A8U WayPoint30A8DU
- 24VAC @ 12.5 amp or 28VAC @ 10 amp. - 24VAC @ 12.5 amp or 28VAC @ 10 amp.
- Eight (8) fuse protected outputs. - Eight (8) PTC protected outputs.
Rev. 091514-30A More than just power.™
Overview:
WayPoint Outdoor Power Supplies provide 24VAC and/or 28VAC distributed via two (2), four (4) or eight (8) output(s) for powering CCTV Cameras, heaters, and other video accessories.
WayPoint AC Reference Chart:
Altronix Model Number
WayPoint30ADU
WayPoint30A4U
WayPoint30A4DU
WayPoint30A8U
WayPoint30A8DU
*Lower rated fuses can be used.
Output Voltage
24VAC and 28VAC 10 amp 1 of each
Total
Output
Current
(Power)
24VAC 12.5 amp
24VAC 12.5 amp 28VAC 10 amp 24VAC 10 amp 28VAC 10 amp 24VAC 12.5 amp 28VAC 10 amp 24VAC 12.5 amp 28VAC 10 amp
Number
and Type
of Outputs
2
4 Fused
4 PTCs ----- 2.5 amp 4.68kg
8 Fused
8 PTCs ----- 2.5 amp 4.8kg
Fuse
Output
Ratings
10 amp/
32V
5 amp/
32V
5 amp/
32V
PTC
Output
Ratings
-----
----- 4.68kg
----- 4.8kg
Input Current Draw
115VAC
60Hz
3.0 amp 1.5 amp
230VAC
50Hz
Product
Weight
4.68kg28VAC 10 amp
Specifications:
Agency Listings:
• UL Listed for Information Technology Equipment (UL 60950-1) and Equipment to be Installed Outdoors (UL 60950-22).
• CE European Conformity.
Input:
• Input: 115VAC 60Hz, 3 amp or 230VAC 50Hz, 1.5 amp.
Output:
• Output options: a. 24VAC or 28VAC. b. Both 24VAC and 28VAC (WayPoint30ADU only).
• Fuse ratings: WayPoint30A4U and WayPoint30A8U: 5A.
Visual Indicators:
• Individual power output LED indicators.
• Illuminated master power switch.
Features:
• Surge suppression.
• Spare fuses included.
Accessories:
• Optional PMK1 Pole Mount Kit simplifies installation of outdoor units.
Enclosure:
• NEMA 4/4X, IP66-11 Rated enclosure for outdoor use.
• Enclosure Dimensions (H x W x D approx.):
13.31” x 11.31” x 5.59” (338.074 mm x 287.274 mm x 141.986 mm).
Installation Instructions:
Unit should be installed in accordance with The National Electrical Code and all applicable Local Regulations.
1. Remove back plane from enclosure prior to mounting (do not discard hardware).
2. Mark and drill desired inlets on the enclosure to facilitate wiring (Fig. 1, pg. 3).
3. Mount unit in desired location. Mark and drill holes to line up with the top and bottom holes of the enclosure flange. Secure enclosure with appropriate fasteners (Fig. 5, pg. 7 and Fig. 11, pg. 8).
4. Mount back plane to enclosure with hardware.
5. Set the input voltage selector switch for 115VAC or 230VAC operation (Figs. 2-4, pgs. 4-6)
6. To facilitate wire entry utilize weather-tight NEMA 4 rated connectors, bushings, and cable.
7. Set illuminated master power disconnect circuit breaker to the [OFF] position (Figs. 2-4, pgs. 4-6).
8. Connect unswitched AC power (115VAC/230VAC 50/60 Hz) to terminals marked [L, N] (Figs. 2-4, pgs. 4-6). Green branch wire connects to earth (safety) ground lug . Wire gauge range of connectors is 14 AWG to 11 AWG (1.6 mm to 2.5 mm diameter).
9. Set illuminated master power disconnect circuit breaker to the (RESET/ON) position (Figs. 2-4, pgs. 4-6).
10. WayPoint30A4U/A4DU, WayPoint30A8U/A8DU are factory set for 24VAC operation. For 28VAC operation adjust unit prior to mounting and applying power as follows: Change the wire position so that the black wire [28V] is connected to the terminal marked [P] and the yellow wire [24V] is connected to the terminal marked [S].
11. Measure output voltage on terminals marked [COM, 24V, 28V] on WayPoint30ADU (Fig. 2, pg. 4) or [1-4 or 1-8 COM] on WayPoint30A4U, WayPoint30A4DU, WayPoint30A8U and WayPoint30A8DU before connecting devices (Fig. 3, pg. 5, Fig. 4, pg. 6). This helps avoiding potential damage.
- 2 - WayPoint30A
12. Set illuminated master power disconnect circuit breaker to the [OFF] position (Figs. 2-4, pgs. 4-6).
13. Connecting devices to WayPoint30ADU: For 24VAC output connect devices to terminals marked [COM, 24V] (Fig. 2, pg. 4). For 28VAC output connect devices to terminals marked [COM, 28V] (Fig. 2, pg. 4). Connecting devices to WayPoint30A4U or WayPoint30A4DU: Connect device to terminals marked [1-4] and [COM] (Fig. 3, pg. 5).
Connecting devices to WayPoint30A8U or WayPoint30A8DU:
Connect device to terminals marked [1-8] and [COM] (Fig. 4, pg. 6).
14. Set illuminated master power disconnect circuit breaker to the [RESET/ON] position (Figs. 2-4, pgs. 4-6).
15. LEDs will illuminate indicating each output is powered (Figs. 2-4, pgs. 4-6).
16. Upon completion of wiring secure enclosure door with latches and optional lock. Caution: Equipment to be installed / serviced by authorized / trained personnel only.
Shut branch circuit power before installing / servicing equipment.
WARNING: When installing in a non-restricted service area use lock or other fastened means on door latches. This installation should be made by qualified service personnel and should conform to all local codes and in accordance with the National Electrical Code.
LED Identification Chart:
ON OFF
Normal operating condition.
To reset a tripped PTC turn the power off for 1 minute and then turn it back on.
No AC output. Blown fuse or tripped PTC, illuminated master power disconnect circuit breaker is tripped or OFF, AC failure.
Technical Specifications:
Parameter Description Input power
requirements
Indicators
Environmental Conditions
Regulatory Compliance
For fuse protected models:
Replace blade type fuses with ratings from 3A up to 10A. WayPoint30A4U and WayPoint30A8U incorporate 5A fuses.
The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient magnitude to constitute an electric shock.
115VAC 60Hz, 3 amp or 230VAC 50Hz, 1.5 amp.
Individual power output LED indicators. Illuminated master power switch.
Operating Ambient Temperature:
For 24VAC @ 12.5 amp output -40°C to 60°C (-40°F to 140ºF). For 28VAC @ 10.0 amp output -40°C to 70°C (-40°F to 158ºF).
Relative Humidity: 85%, +/- 5% Storage Temperature: -40ºC to 75ºC (-40ºF to 167ºF). Operating Altitude: -1000 to 6,561.679 ft. (-304.8 to 2000m).
UL Listed for Information Technology Equipment (UL 60950-1) and
Equipment to be Installed Outdoors (UL 60950-22). CE European Conformity.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open enclosure. There are no user serviceable parts inside. Refer servicing to qualified service personnel.
WayPoint30A - 3 -