WayPoint Outdoor Power Supplies provide 24VAC and/or 28VAC distributed via two (2), four (4) or eight (8) output(s)
for powering CCTV Cameras, heaters, and other video accessories.
• Output options:
a. 24VAC or 28VAC.
b. Both 24VAC and 28VAC (WayPoint30ADU only).
• Fuse ratings:
WayPoint30A4U and WayPoint30A8U: 5A.
Visual Indicators:
• Individual power output LED indicators.
• Illuminated master power switch.
Features:
• Surge suppression.
• Spare fuses included.
Accessories:
• Optional PMK1 Pole Mount Kit simplifies installation of
outdoor units.
Enclosure:
• NEMA 4/4X, IP66-11 Rated enclosure for outdoor use.
• Enclosure Dimensions (H x W x D approx.):
13.31” x 11.31” x 5.59”
(338.074 mm x 287.274 mm x 141.986 mm).
Installation Instructions:
Unit should be installed in accordance with The National Electrical Code and all applicable Local Regulations.
1. Remove back plane from enclosure prior to mounting (do not discard hardware).
2. Mark and drill desired inlets on the enclosure to facilitate wiring (Fig. 1, pg. 3).
3. Mount unit in desired location. Mark and drill holes to line up with the top and bottom holes of the enclosure flange.
Secure enclosure with appropriate fasteners (Fig. 5, pg. 7 and Fig. 11, pg. 8).
4. Mount back plane to enclosure with hardware.
5. Set the input voltage selector switch for 115VAC or 230VAC operation (Figs. 2-4, pgs. 4-6)
6. To facilitate wire entry utilize weather-tight NEMA 4 rated connectors, bushings, and cable.
7. Set illuminated master power disconnect circuit breaker to the [OFF] position (Figs. 2-4, pgs. 4-6).
8. Connect unswitched AC power (115VAC/230VAC 50/60 Hz) to terminals marked [L, N] (Figs. 2-4, pgs. 4-6).
Green branch wire connects to earth (safety) ground lug .
Wire gauge range of connectors is 14 AWG to 11 AWG (1.6 mm to 2.5 mm diameter).
9. Set illuminated master power disconnect circuit breaker to the (RESET/ON) position (Figs. 2-4, pgs. 4-6).
10. WayPoint30A4U/A4DU, WayPoint30A8U/A8DU are factory set for 24VAC operation.
For 28VAC operation adjust unit prior to mounting and applying power as follows:
Change the wire position so that the black wire [28V] is connected to the terminal marked [P] and
the yellow wire [24V] is connected to the terminal marked [S].
11. Measure output voltage on terminals marked [COM, 24V, 28V] on WayPoint30ADU (Fig. 2, pg. 4)or [1-4 or 1-8 COM] on WayPoint30A4U, WayPoint30A4DU, WayPoint30A8U and WayPoint30A8DU before connecting devices (Fig. 3, pg. 5, Fig. 4, pg. 6). This helps avoiding potential damage.
- 2 - WayPoint30A
Page 3
12. Set illuminated master power disconnect circuit breaker to the [OFF] position (Figs. 2-4, pgs. 4-6).
13. Connecting devices to WayPoint30ADU:For 24VAC output connect devices to terminals marked [COM, 24V] (Fig. 2, pg. 4).
For 28VAC output connect devices to terminals marked [COM, 28V] (Fig. 2, pg. 4).
Connecting devices to WayPoint30A4U or WayPoint30A4DU:Connect device to terminals marked [1-4] and [COM] (Fig. 3, pg. 5).
Connecting devices to WayPoint30A8U or WayPoint30A8DU:
Connect device to terminals marked [1-8] and [COM] (Fig. 4, pg. 6).
14. Set illuminated master power disconnect circuit breaker to the [RESET/ON] position (Figs. 2-4, pgs. 4-6).
15. LEDs will illuminate indicating each output is powered (Figs. 2-4, pgs. 4-6).
16. Upon completion of wiring secure enclosure door with latches and optional lock.
Caution: Equipment to be installed / serviced by authorized / trained personnel only.
Shut branch circuit power before installing / servicing equipment.
WARNING: When installing in a non-restricted service area use lock or other fastened means on door
latches. This installation should be made by qualified service personnel and should conform to all local
codes and in accordance with the National Electrical Code.
LED Identification Chart:
ONOFF
Normal operating condition.
To reset a tripped PTC turn the power off for 1 minute and then turn it back on.
No AC output. Blown fuse or tripped PTC, illuminated master power
disconnect circuit breaker is tripped or OFF, AC failure.
Technical Specifications:
ParameterDescription
Input power
requirements
Indicators
Environmental
Conditions
Regulatory
Compliance
For fuse protected models:
Replace blade type fuses with ratings from 3A up to 10A.
WayPoint30A4U and WayPoint30A8U incorporate 5A fuses.
The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the
presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient
magnitude to constitute an electric shock.
115VAC 60Hz, 3 amp or 230VAC 50Hz, 1.5 amp.
Individual power output LED indicators.
Illuminated master power switch.
Operating Ambient Temperature:
For 24VAC @ 12.5 amp output -40°C to 60°C (-40°F to 140ºF).
For 28VAC @ 10.0 amp output -40°C to 70°C (-40°F to 158ºF).
Relative Humidity: 85%, +/- 5%
Storage Temperature: -40ºC to 75ºC (-40ºF to 167ºF).
Operating Altitude: -1000 to 6,561.679 ft. (-304.8 to 2000m).
UL Listed for Information Technology Equipment (UL 60950-1) and
Equipment to be Installed Outdoors (UL 60950-22).
CE European Conformity.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open enclosure. There are
no user serviceable parts inside. Refer servicing to qualified service personnel.
WayPoint30A - 3 -
Page 4
Fig. 1
Fig. 2 - WayPoint30ADU (PTCs)
Suggested Locations
for Wiring Inlets
Bottom of Enclosure
XFMR*
INPUT
28V 24V COM
28V 24V COM
Input Voltage
115V
PD2WP
COM 24V 28V
COM 24V 28V
115
LGN
ALTRONIX CORP.
www.altronix.com
BROOKLYN, NY 11220
HIGH VOLTAGE
CAUTION
230
Power Input
Ground
Lug
- 4 - WayPoint30A
Page 5
Fig. 3 - WayPoint30A4U (Fuses)
XFMR*
S P N
5
5
5
5
115230
115V
RESET
LGN
ALTRONIX CORP.
PD4WP
1 COM 2 COM 3 COM 4 COM
www.altronix.com
BROOKLYN,NY 11220
CAUTION
HIGH VOLTAGE
Ground
Circuit board incorporated in WayPoint30A4DU (PTCs)
5A 32V
Fuses F1-F8
S P N
115230
115V
RESET
Lug
LGN
ALTRONIX CORP.
PD4WPCB
1 COM 2 COM 3 COM 4 COM
www.altronix.com
BROOKLYN,NY 11220
WayPoint30A - 5 -
Page 6
Fig. 4 - WayPoint30A8U (Fuses)
XFMR*
5
5
5
5
S P N
1 2 3 4 5 6 7 8
5
5
5
5
115230
115V
RESET
P
LGN
N
ALTRONIX CORP.
PD8WP
1 2 3 4 5 6 7 8
Common
www.altronix.com
BROOKLYN,NY 11220
CAUTION
HIGH VOLTAGE
Circuit board incorporated in WayPoint30A8D (PTCs)
S P N
1 2 3 4 5 6 7 8
115230
115V
RESET
P
Ground
Lug
LGN
N
ALTRONIX CORP.
PD8WPCB
1 2 3 4 5 6 7 8
Common
www.altronix.com
BROOKLYN,NY 11220
- 6 - WayPoint30A
Page 7
Wall Mount Installation
1- Place unit at desired location and secure with mounting
screws (not included) (Fig. 5, pg. 7).
Fig. 5
Pole Mounting Using Optional Pole Mount Kit PMK1 (not included):
This installation should be made by qualified service personnel. This product contains no serviceable parts. PMK1 is intended for use with Altronix outdoor rated power supplies or accessories housed in WP1, WP2, WP3 and WP4 enclosures.
Brackets are designed for use with the Wormgear Quick Release Straps (two included).
1. Thread one (1) wormgear quick release strap through the slots on the back of a mounting bracket (Fig. 6, pg. 7).
2. Once the desired height of the top Pole Mount bracket is achieved, tighten the straps down by sliding open end
of the strap through the locking mechanism on the strap, then tighten the screw with
flat head screwdriver or 5/16” hex socket driver (Fig. 7, pg. 7).
Fig. 6
Fig. 7
Fig. 8
3. Attach the bottom bracket to the enclosure by inserting bolts through the
flange of the enclosure and into the bracket, tightening bolts with a
7/16” hex socket (Fig. 9, pg. 7).
4. Thread the second wormgear quick release strap through the slots on the
back of the bottom mounting bracket (Fig. 6, pg. 7).
5. Mount enclosure onto the top bracket by inserting bolts through
flange of the enclosure and into the bracket,
tightening bolts with a 7/16” hex socket (Fig. 8, pg. 7).
6. Tighten the straps of the bottom bracket down by sliding the open end of
the strap through the locking mechanism on the strap, then tighten screw
with flat head screwdriver or 5/16” hex socket driver (Fig. 10/10a, pg. 7).
7. Clip excess straps.
Fig. 10 - 2” to 8”(50.8mm to 203.2mm) Fig. 10a - 5” (127mm) square pole
diameter round pole
Fig. 9
WayPoint30A - 7 -
Page 8
Enclosure Dimensions (H x W x D):
13.31” x 11.31” x 5.59” (338.074 mm x 287.274 mm x 141.986 mm)
Fig. 11
STAINLESS STEEL PIANO HINGE
8.00” (203.2mm)
Ø 0.32 (8.128mm) MOUNTING HOLE
TYP. 4 PLACES
(142.24mm)
5.60”
WITH RIVETS (Ø 0.375” (9.52mm) PADLOCK EYE).
PADLOCK LATCH ATTA CHED
(342.9mm)
13.50”
(338.328mm)
13.32”
(323.85mm)
12.75”
(304.8mm)
12.00”
11.32” (287.528mm)
(40.894mm)
1.61”
(100.584mm)
3.96”
10-32 X 0.375” (9.525mm)
BRASS INSERT (X4)
10.75” (273.05mm)
8.25” (209.55mm)
10.00” (254mm)
10-32 X 0.25” (6.35mm)
BRASS INSERT (X2)
(260.35mm)
10.25”
Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
website: www.altronix.com, e-mail: info@altronix.com. Lifetime Warranty, Made in U.S.A.
- 8 - WayPoint30A
IIWayPoint30A L21O
MEMBER
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.