Altronix WAYPOINT17AU, WAYPOINT17A8DU, WAYPOINT17A8U Installation Guide

WayPoint17A Series
AC Outdoor Power Supplies
Installation Guide
Models Include:
WayPoint17AU
- Two (2) fuse protected outputs.
WayPoint17A4U
- Four (4) fuse protected outputs.
WayPoint17A8U
- Eight (8) fuse protected outputs.
Rev. 091514-17A
WayPoint17ADU
- 24VAC @ 7.25A and/or 28VAC @ 6.25A.
- Two (2) PTC protected outputs.
WayPoint17A4DU
- 24VAC @ 7.25A and/or 28VAC @ 6.25A.
- Four (4) PTC protected outputs.
WayPoint17A8DU
- 24VAC @ 7.25A and/or 28VAC @ 6.25A.
- Eight (8) PTC protected outputs.
More than just power.
TM
Altronix WayPoint Outdoor Power Supplies provide 24VAC and/or 28VAC distributed via two (2), four (4) or
COM 24V 28V
COM 24V 28V
PD2WP
28V 24V COM
Input Voltage
Power Input
115V
115
230
LGN
ALTRONIX CORP.
www.altronix.com
BROOKLYN,NY 11220
eight (8) outputs for powering CCTV cameras, heaters, and other video accessories.
WayPoint17A Series AC Reference Chart:
Overview:
Altronix Model Number Output Voltage
24VAC 7.25A
WayPoint17AU
24VAC and 28VAC 6.25A 1 of each
24VAC 7.25A
WayPoint17ADU
24VAC and 28VAC 6.25A 1 of each
WayPoint17A4U
WayPoint17A4DU
WayPoint17A8U
WayPoint17A8DU
*Lower rated fuses can be used.
24VAC 7.25A
28VAC 6.25A
24VAC 7.25A
28VAC 6.25A
24VAC 7.25A
28VAC 6.25A
24VAC 7.25A
28VAC 6.25A
Total
Output Current (Power)
Number
and Type
of Outputs
4 Fused
4 PTCs ----- 2.5A 5.95kg
8 Fused
8 PTCs ----- 2.5A 6.1kg
Fuse Output Ratings
2
5A/
32V*
2
----- 2.5A 5.95kg28VAC 6.25A
5A/
32V*
5A/
32V*
Input Current Draw
PTC
Output
115VAC
Ratings
60Hz
-----
2.0A 1A
----- 5.95kg
----- 6.1kg
230VAC
50Hz
Product
Weight
5.95kg28VAC 6.25A
Specifications:
Agency Listings:
• UL/cUL Listed: UL 60950-1 Information Technology Equipment. UL 60950-22 Equipment to be Installed Outdoors.
• CE European Conformity.
Input:
• Input: 115VAC, 60Hz, 2A or 230VAC, 50Hz, 1A.
Output:
• Output options: a. 24VAC or 28VAC. b. Both 24VAC and 28VAC (WayPoint17AU/ADU only).
• Fuse ratings: WayPoint17A Series incorporate 5A/32V fuses.
Visual Indicators:
• Individual power output LED indicators.
• Illuminated master power switch.
Features:
• Surge suppression.
• Spare fuses included.
Accessories:
• Optional PMK1 Pole Mount Kit simplifies installation of outdoor units.
Enclosure:
• NEMA 4/4X, IP66-11 Rated enclosure for outdoor use.
• Enclosure Dimensions (H x W x D approx.):
13.31” x 11.31” x 5.59” (338.1 mm x 287.3 mm x 142 mm).
Installation Instructions:
Unit shall be installed in accordance with The National Electrical Code and all applicable Local Regulations.
1. Remove backplane from enclosure prior to mounting (do not discard hardware).
2. Mark and drill desired inlets on the enclosure to facilitate wiring (Fig. 1, pg. 4). Note: Inlets for conduit fittings should only be made on the bottom of the enclosure. UL Listed NEMA type 4X rated conduit connector/hubs shall be used for the appropriate size inlets.
3. Mount unit in desired location. Mark and drill holes to line up with the top and bottom holes of the enclosure flange. Secure enclosure with appropriate fasteners (Fig. 5, pg. 7 and Fig. 11, pg. 8).
4. Mount back plane to enclosure with hardware.
5. Set the input voltage selector switch for 115VAC or 230VAC operation (Figs. 2-4, pgs. 4-6)
6. To facilitate wire entry utilize weather-tight NEMA 4 rated connectors, bushings, and cable.
7. Set illuminated master power disconnect circuit breaker to the [OFF] position (Figs. 2-4, pgs. 4-6).
8. Connect unswitched AC power (115VAC/230VAC, 50/60 Hz) to terminals marked [L, N] (Figs. 2-4, pgs. 4-6). Green branch wire connects to earth (safety) ground lug . Wire gauge range of connectors is 14 AWG to 11 AWG (1.6 mm to 2.5 mm diameter).
9. Set illuminated master power disconnect circuit breaker to the [RESET/ON] position (Figs. 2-4, pgs. 4-6).
- 2 - WayPoint17A Series
10. WayPoint17A4U/A4DU, WayPoint17A8U/A8DU are factory set for 24VAC operation. For 28VAC operation adjust unit prior to mounting and applying power as follows: Change the wire position so that the black wire [28V] is connected to the terminal marked [P] and the yellow wire [24V] is connected to the terminal marked [S].
11. Measure output voltage on terminals marked [COM, 24V, 28V] on WayPoint17AU or WayPoint17ADU (Fig. 2, pg. 4) or [1-4] or [1-8 COM] on WayPoint17A4U, WayPoint17A4DU, WayPoint17A8U and WayPoint17A8DU before connecting devices (Fig. 3, pg. 5, Fig. 4, pg. 6). This helps avoiding potential damage.
12. Set illuminated master power disconnect circuit breaker to the [OFF] position (Figs. 2-4, pgs. 4-6).
13. Connecting devices to WayPoint17AU or WayPoint17ADU: For 24VAC output connect devices to terminals marked [COM, 24V] (Fig. 2, pg. 4). For 28VAC output connect devices to terminals marked [COM, 28V] (Fig. 2, pg. 4). Connecting devices to WayPoint17A4U or WayPoint17A4DU: Connect device to terminals marked [1-4] and [COM] (Fig. 3, pg. 5).
Connecting devices to WayPoint17A8U or WayPoint17A8DU:
Connect device to terminals marked [1-8] and [COM] (Fig. 4, pg. 6).
14. Set illuminated master power disconnect circuit breaker to the [RESET/ON] position (Figs. 2-4, pgs. 4-6).
15. LEDs will illuminate indicating each output is powered (Figs. 2-4, pgs. 4-6).
16. Upon completion of wiring secure enclosure door with latches and optional lock. Caution: Equipment to be installed / serviced by authorized / trained personnel only.
Shut branch circuit power before installing / servicing equipment.
WARNING: When installing in a non-restricted service area use lock or other fastened means on door latches. This installation should be made by qualified service personnel and should conform to the National Electrical Code and all local codes.
LED Identification Chart:
ON OFF
Normal operating condition.
No AC output. Blown fuse or tripped PTC, illuminated master power disconnect circuit breaker is tripped or OFF, AC failure.
To reset a tripped PTC turn the power off for 1 minute and then turn it back on.
Technical Specifications:
Parameter Description Input power requirements
Indicators
Environmental Conditions
Regulatory Compliance
115VAC, 60Hz, 2A or 230VAC, 50Hz, 1A. Individual power output LED indicators.
Illuminated master power switch.
Operating Ambient Temperature:
For 24VAC @ 4A output: - 40°C to 60°C (- 40°F to 140ºF). For 28VAC @ 3.5A output: - 40°C to 70°C (- 40°F to 158ºF).
Relative Humidity: 85%, +/- 5% Storage Temperature: - 40ºC to 75ºC (- 40ºF to 167ºF). Operating Altitude: - 304.8 to 2,000m.
UL/cUL Listed for Information Technology Equipment (UL 60950-1)
Equipment to be Installed Outdoors (UL 60950-22).
CE European Conformity.
For fuse protected models:
Replace fuses with the same type and rating 5A/32V.
5A
32V
The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open enclosure. There are no user serviceable parts inside. Refer servicing to qualified service personnel.