Altronix VertiLine8i Installation Instructions

Page 1
CCTV Isolated Rack Mount Power Supplies
Installation Guide
Models Include:
Vertiline8i Vertiline8Di
- 24VAC or 28VAC @ 8 amp - 24VAC or 28VAC @ 8 amp
- Eight (8) fuse protected electronically - Eight (8) PTC protected electronically isolated outputs isolated outputs
- 24VAC or 28VAC @ 16 amp - 24VAC or 28VAC @ 16 amp
- Sixteen (16) fuse protected electronically - Sixteen (16) PTC protected electronically isolated outputs isolated outputs
Rev. 031808
More than just power.
TM
Page 2
Overview:
Altronix Vertiline AC Isolated CCTV Rack Mount Power Supplies provide 8 or 16 camera channels in a space saving 1U EIA 19” rack mount chassis which may be rack, wall or shelf mounted. The units feature individually selectable 24VAC and/or 28VAC power outputs.
Specifications:
• Selectable 115VAC 60 Hz /230VAC 50/60 Hz input.
• Eight (8) or sixteen (16) individually selectable
24VAC or 28VAC power outputs with OFF position.
• Maximum 1 amp per output.
• Individual electronically isolated outputs.
• Eight (8) or sixteen (16) power LED indicators.
• External automotive blade fuses or
PTC protected outputs.
• Illuminated power disconnect circuit breaker with manual reset.
• Removable terminal blocks with locking screw flange.
• Ease of installation saves time and eliminates costly labor.
• Compact 1U rack mount chassis.
• Fits standard EIA 19” rack.
• Units can be rack, wall or shelf mounted.
Eight (8) & Sixteen (16) Output Rack Mount Configuration Reference Chart:
Altronix Model Number
Vertiline8i
Vertiline8Di
Vertiline16i
Vertiline16Di
Voltage (VAC)
Output
24VAC or
28VAC
24VAC or
28VAC
24VAC or
28VAC
24VAC or
28VAC
Total Output Current (Power)
8 amp 8
8 amp 8
16 amp 16
16 amp 16
Number of Isolated Outputs
Output Protection
Fused -- 3 amp 3 amp
-- PTC 2.5 amp --
Fused -- 3 amp 3 amp
-- PTC 2.5 amp --
Output Protection
Class 2 Rated Power Limited
(max. per output)
Current
Fuse Rating
2.5 amp 1.5 amp
Input Current
115VAC 60Hz
Input Current
230VAC 50/60Hz
5 amp 2.5 amp
Agency Listings
UL Listed for Commercial
CCTV Equipment (UL 2044).
CUL Listed - CSA Standard
C22.2 No.1-04,
Audio, Video and Similar Equipment.
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This installation should be made by qualified service personnel and should conform to all local codes and in accordance with the National Electrical Code.
Installation Instructions:
1. Set the input voltage selector switch located on the left side of the Vertiline unit for 115VAC or 230VAC operation (Fig. 1c, pg. 4).
2.
Attach mounting brackets to Vertiline unit for rack or wall mount installation (Figs. 4-5, pg. 7). Affix rubber pads to Vertiline for shelf installation (Fig. 6, pg. 7).
3.
Secure the unit in a rack, mount unit to a w 3” from any video monitors).When installing the unit in a rack allow for one half of a U spacing above the unit for ventilation.
4. Plug the grounded AC line cord (included) into the IEC 320 connector of the Vertiline unit (Fig. 1f, pg. 4). Inser
t the plug end of the line cord into a g
5. Set illuminated master power disconnect circuit breaker to the (ON) position (Fig. 3, pg. 6).
6.
Select 24V
AC or 28VAC power output for cameras 1-8 for Vertiline8i and Vertiline8Di or cameras 1-16 for
Vertiline16i and Vertiline16Di with the corresponding voltage adjustment switches (Fig. 1b, pg. 4).
7. Measure output voltage before connecting cameras. All terminals with common suffix (P) “1P, 2P ...” are the same polarity.
8. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 3, pg. 6).
- 2 - Vertiline8i/Vertiline16i
all or place unit on a shelf as desired (unit should be spaced at least
rounded AC receptacle.
This helps a
void potential damage.
Page 3
9. Connect the power outputs of terminals marked [1P & 1N] to the power inputs of camera 1 (Fig. 2, pg. 5). Repeat this step for each additional camera (Outputs 2-16). After wiring is completed insert terminal block into the
corresponding connector and secure by tightening the screws.
10. Upon completion of wiring, set illuminated master power disconnect circuit breaker to the ON (RESET) position (Fig. 3, pg. 6).
1
1
. The power LEDs (Green) on the faceplate for Outputs 1-8 for Vertiline8i and Vertiline8Di or Outputs 1-16 for
Vertiline16i and Vertiline16Di will illuminate when AC power is present (Fig. 1a, pg. 4). If all of the LEDs are OFF there ma
y be a complete loss of suppl
y power to the Vertiline unit or the illuminated master power disconnect circuit
breaker is in the OFF position.
To restore the power output for Vertiline8i or Vertiline16i:
1- Switch corresponding output voltage switch to the OFF position (Fig. 1b, pg. 4). 2-
Eliminate the troub
3- Replace the corresponding automotive blade fuse.
Replace fuses with same type and rating:
le condition.
Automotive Blade Fuse
Output fuses are rated @ 3 amp for all models.
4-
Switch output v
oltage switch to the 24VAC or 28VAC position as desired (Fig. 1b, pg. 4).
To restore the power output for Vertiline8Di or Vertiline16Di:
1- Switch corresponding output voltage switch to the OFF position (Fig. 1b, pg. 4). 2-
Eliminate the troub
le condition. 3- Allow 1 minute for PTC to cool off. 4- Switch output voltage switch to the 24VAC or 28VAC position as desired (Fig. 1b, pg. 4).
Vertiline8i/Vertiline16i - 3 -
Page 4
28VAC
OFF
24VAC
1
2
3 4 5
6
7 8 9 10 11 12 13 14 15 16
28VAC
OFF
24VAC
OFF
RESET
AC POWER
13141516
N
P
N
P
N
P
N
P
9101112
N
P
N
P
N
P
N
P
5678
N
P
N
P
N
P
N
P
1234
N
P
N
P
N
P
N
P
AC POWER
13141516
N
P
N
P
N
P
N
P
9101112
N
P
N
P
N
P
N
P
5678
N
P
N
P
N
P
N
P
1234
N
P
N
P
N
P
N
P
1f - IEC 320
115VAC 220VAC
Connector: 115VAC
60Hz/230VAC
50/60Hz (grounded line
cord included).
1c - Input Voltage Switch:
Selects 115VAC/230VAC
50/60Hz (switch is located
on the left side of the unit).
1b - Output voltage switches:
Selects 24VAC or 28VAC
or OFF for each output.
1e - Output Fuses:
Automotive blade fuses.
1d - Power Outputs:
24VAC or 28VAC.
Fig. 1
1a - LED(s) 1-16:
Video signal indicators.
Vertiline16i and Vertiline16Di (front)
Vertiline16i (rear)
Vertiline16Di (rear)
- 4 - Vertiline8i/Vertiline16i
PTC protected models (Vertiline8Di and Vertiline16Di) do not have output fuses on the
rear of rack mount chassis. The PTCs are located on the inside of the rack mount chassis.
Page 5
28VAC
OFF
24VAC
1
2
3 4 5
6
7 8 9 10 11 12 13 14 15 16
28VAC
OFF
24VAC
OFF
RESET
AC POWER
13141516
N
P
N
P
N
P
N
P
9101112
N
P
N
P
N
P
N
P
5678
N
P
N
P
N
P
N
P
1234
N
P
N
P
N
P
N
P
Typical Hookup:
Fig. 2
Vertiline8i/Vertiline16i - 5 -
Page 6
1
.625"
8.5"
.75"
19.125"
17.625"
(ON)
AC POWER
13141516
NPNPNPN
P
9101112
NPNPNPN
P
5
678
NPNPNPN
P
1
234
NPNPNPN
P
28VAC
OFF
24VAC
1
2
34 5678 910 11 12 13 14 15 16
28VAC
OFF
24VAC
OFF
RESET
The lightning flash with ar presence of an insulated “DANGEROUS VOLTAGE” within the products enclosure that may be of sufficient magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
1U EIA 19” Rack Mount Chassis Mechanical Drawing & Dimensions:
1.625”H x 19.125”W x 8.5”D
ro
w head symbol within an equilateral triangle is intended to alert the user to the
CAUTION: To reduce the risk of electric shock do not open enclosure. There are no user ser
le parts inside. Refer servicing to qualified service personnel.
viceab
REAR
TOP & BOTTOM
FRONT
Fig. 3
Power switch with built-in circuit breaker:
OFF position - Switch not Illuminated. Outputs not pow RESET (ON) position - Switch illuminated. Outputs powered. Circuit breaker tripped - Switch not Illuminated. Power LEDs on faceplate are not illuminated. Outputs not powered. To reset circuit breaker set power switch to the ON (RESET) position (Fig. 3, pg. 6).
ered.
- 6 - Vertiline8i/Vertiline16i
Page 7
Mounting Options:
B
A
C
B
A
C
A
B
Rack Mount Installation
1- Remove factory installed screws from both sides of rack chassis (Fig. 4a). 2- Install mounting brackets (A) on the left and right side of rack chassis using the
two (2) flat head screws (B) (included) (Fig. 4b).
3-
Place unit into desired EIA 19” rack position and secure with mounting scre
Fig. 4
ws (not included) (Fig. 4c).
Fig. 4a
Top Top
Fig. 4b
Fig. 4c
To
Front
F
ront
Left
Left
Front Left
Remove
Wall Mount Installation
1- Install mounting brackets (A) on the left and right side of rack chassis using
two (2) flat head screws (B) (included) (Fig. 5a).
2- Place unit at desired location and secure with mounting scre
Caution: It is necessary to make sure mounting screws are securely fastened to a beam when installing.
Fig. 5
Fig. 5a
Fig. 5b
ws (not included) (Fig. 5b).
p
Shelf Installation
1- Position and affix rubber pads (C) (included) at each
corner on the bottom of the unit (Fig. 6).
2- Place unit in desired location.
Fig
. 6
Left Side
Mounting Hardware (Included):
Two (2) mounting brackets
Six (6) flat head screws for mounting brackets.
Four (4) rubber pads.
Rubber Pad
Vertiline8i/Vertiline16i - 7 -
Page 8
Notes:
Altronix is not responsible for any typographical errors.
Altronix Corp. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 web site: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A. IIVertiline8i/Vertiline16iSeries J10H
- 8 - Vertiline8i/Vertiline16i