![](/html/34/3489/348930965ca71191320129cffbfa0c0c2cff665175ac4c1c15a18eef5b08d3d4/bg1.png)
CCTV Rack Mount Power Supplies
Installation Guide
Models Include:
Vertiline8 Vertiline8D
- 24VAC or 28VAC @ 5A - 24VAC or 28VAC @ 5A
- Eight (8) fuse protected outputs - Eight (8) PTC protected outputs
Vertiline83 Vertiline83D
- 24VAC or 28VAC @ 10A - 24VAC or 28VAC @ 10A
- Eight (8) fuse protected outputs - Eight (8) PTC protected outputs
Rev. 031808
More than just power.
TM
![](/html/34/3489/348930965ca71191320129cffbfa0c0c2cff665175ac4c1c15a18eef5b08d3d4/bg2.png)
Overview:
Altronix Vertiline CCTV Rack Mount Power Supplies provide 8 power outputs in a space saving 1U EIA 19” rack mount
chassis which may be rack, wall or shelf mounted. The units feature individually selectable 24VAC and/or 28VAC power
outputs with surge suppression. Vertiline CCTV Rack Mount Power Supplies are also available in sixteen (16) and twentyfour (24) output models with various power ratings.
Specifications:
Input:
• Selectable 115VAC 60 Hz or 240VAC 50/60 Hz input.
Output:
• Eight (8) individually selectable 24VAC or 28VAC fuse
or PTC protected power outputs with OFF position.
• Outputs are rated @ 3.5A (fused) or 2.5A (PTC).
• Surge suppression.
Features:
• Eight (8) power LEDs.
• Removable terminal blocks with locking screw flange.
Features (cont’d):
• Illuminated master power disconnect circuit breaker
with manual reset.
• IEC 320 - 3-wire grounded line cord (detachable).
Mechanical:
• Units can be rack, wall or shelf mounted.
• Modular 1U standard EIA 19” rack mount chassis
• Enclosure Dimensions (H x W x D approx.):
1.625” x 19.125” x 8.5” (41.3mm x 486mm x 216mm).
Eight (8) Output Rack Mount Configuration Reference Chart:
Altronix
Model
Output
Number
Vertiline8
Vertiline8D
Vertiline83
Vertiline83D
Voltage (VAC)
24VAC or
28VAC
24VAC or
28VAC
24VAC or
28VAC
24VAC or
28VAC
Total Output
Current (Power)
Number of Outputs
5A 8
5A 8
10A 8
10A 8
Fused -- 3A 3A
Fused -- 3A 3A
Output Protection
Class 2 Rated
Power-Limited
Output Protection
Current
(max. per output)
-- PTC 2.5A --
-- PTC 2.5A --
Fuse Rating
Main Fuse Rating
115VAC 60Hz
Input Current
10A 1.5A 0.8A
15A 3A 1.5A
230VAC 50/60Hz
Input Current
Agency Listings
CCTV Equipment
UL Listings and
File Numbers
UL Listed for
Commercial
(UL 2044).
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture.
This installation should be made by qualified service personnel and should conform to the National
Electrical Code and all local codes.
Installation Instructions:
1. Set the input voltage selector switch located on the left side of the Vertiline unit (facing front panel) for
115VAC or 230VAC operation (Fig. 1c, pg. 4).
2. Attach mounting brackets to Vertiline unit for rack or wall mount installation (Figs. 4-5, pg. 7). Affix rubber pads to
Vertiline for shelf installation (Fig. 6, pg. 7).
3. Secure the unit in a rack, mount unit to a wall or place unit on a shelf as desired (unit should be spaced at least 3”
from any video monitors). When installing the unit in a rack allow for one half of a U spacing above the unit
for ventilation.
4. Plug the grounded AC line cord (included) into the IEC 320 connector of the Vertiline unit (Fig. 1g, pg. 4).
Insert the plug end of the line cord into a grounded AC receptacle.
5. Set illuminated master power disconnect circuit breaker to the (ON) position (Fig. 3, pg. 6).
6. Select 24VAC or 28VAC power output for cameras 1-8 with the corresponding voltage adjustment switches
(Fig. 1b, pg. 4).
7. Measure output voltage before connecting cameras. This helps avoiding potential damage.
All terminals with common suffix (P) “1P, 2P ...” are the same polarity.
8. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 3, pg. 6).
- 2 - Vertiline8
![](/html/34/3489/348930965ca71191320129cffbfa0c0c2cff665175ac4c1c15a18eef5b08d3d4/bg3.png)
9. Connect the power outputs of terminals marked [1P & 1N] to the power inputs of camera 1 (Fig. 2, pg. 5).
Repeat this step for each additional camera (Outputs 2-8). After wiring is completed, insert terminal block into the
corresponding connector and secure by tightening the screws.
10. Upon completion of wiring, set illuminated master power disconnect circuit breaker to the
ON (RESET) position (Fig. 3, pg. 6).
11. The power LEDs (Green) on the faceplate for Outputs 1-8 will illuminate when AC power is present (Fig. 1a, pg. 4).
If any of these LEDs are off, a loss of AC power output may be due to a blown fuse or a tripped PTC caused by a
short circuit or overload condition. If all of the LEDs are OFF there may be a complete loss of supply power to the
Vertiline unit or the illuminated master power disconnect circuit breaker is in the OFF position or the main fuse 1-8
is blown (Fig. 1d, pg. 4).*
To restore the power output for Vertiline8 or Vertiline83:
1- Switch corresponding output voltage switch to the OFF position (Fig. 1b, pg. 4).
2- Eliminate the trouble condition.
3- Replace the corresponding automotive blade fuse.*
4- Switch output voltage switch to the 24VAC or 28VAC position as desired (Fig. 1b, pg. 4).
To restore the power output for Vertiline8D or Vertiline83D:
1- Switch corresponding output voltage switch to the OFF position (Fig. 1b, pg. 4).
2- Eliminate the trouble condition.
3- Allow 1 minute for PTC to cool off.
4- Switch output voltage switch to the 24VAC or 28VAC position as desired (Fig. 1b, pg. 4).
*Note: Replace fuses with same type and rating:
Output fuses are rated @ 3A for all models.
Main fuse ratings:
10A for Vertiline8 and Vertiline8D.
Automotive
Blade Fuse
15A for Vertiline83 and Vertiline83D.
Vertiline8 - 3 -