Altronix VertiLine63TD Installation Instructions

Rack Mount Power Supplies
Installation Guide
Models Include:
Vertiline33D
- 12VDC @ 8 amp
- Sixteen (16) PTC protected outputs
Vertiline33TD
- 12VDC @ 16 amp
Vertiline63D
- 24VDC @ 8 amp
Vertiline63TD
- 24VDC @ 16 amp
- Sixteen (16) PTC protected outputs
Rev. 051909
More than just power.
TM
Overview:
Altronix Vertiline Rack Mount Power Supplies provide sixteen (16) filtered and electronically regulated power outputs in a space saving 1U EIA 19” rack mount chassis. The units are available with either 12VDC or 24VDC power outputs. Vertiline Rack Mount Power Supplies are also available with eight (8) outputs.
VertiLine Specifications:
VertiLine33D, VertiLine33TD:
• Sixteen (16) 12VDC power outputs.
VertiLine63D, VertiLine63TD:
• Sixteen (16) 24VDC power outputs.
Common Specifications:
• 115V
AC 60 Hz input.
• Sixteen (16) power LED indicators.
• PTC protected outputs.
• Filtered and electronically regulated.
• Illuminated power disconnect circuit breaker with manual reset.
• IEC 320 - 3-wire grounded line cord (detachable).
• Removable terminal blocks with locking screw flange.
• Ease of installation saves time and eliminates costly labor.
• Compact 1U rack mount chassis.
• Fits standard EIA 19” rack.
• Units can be rack, wall or shelf mounted.
Sixteen (16) Output Rack Mount Configuration Reference Chart:
Altronix Model Number
Vertiline33D
Vertiline33TD
Vertiline63D
Vertiline63TD
Output Voltage (VAC)
12VDC 8 amp 16
12VDC 16 amp 16
24VDC 8 amp 16
24VDC 16 amp 16
Total Output Current (Power)
PTC Output Protection
Number of Outputs
PTC 2.5 amp 1.5 amp
PTC 2.5 amp 3 amp
PTC 2.5 amp 3 amp
PTC 2.5 amp 6 amp
(max. per output)
Current
115VAC 60Hz
Input Current
Agency Listings
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This installation should be made by qualified service personnel and should conform to all local codes and in accordance with the National Electrical Code.
Installation Instructions:
1. Attach mounting brackets to Vertiline unit for rack or wall mount installation (Figs. 3-4, pg. 7).
Affix rubber pads to Vertiline for shelf installation (Fig. 5, pg. 7).
2.
Secure the unit into rack, mount unit to a wall or place unit on a shelf as desired (unit should be spaced at least 3” from any video monitors). When installing the unit in a rack allow for one half U spacing above the unit for ventilation.
3. Insert and secure removable terminal blocks to unit (Fig. 1e, pg. 4).
4.
Plug the grounded AC line cord (included) into the IEC 320 connector of the Vertiline unit (Fig. 1d, pg. 4). Insert the plug end of the line cord into a g
5. Set illuminated master power disconnect circuit breaker to the (ON) position (Fig. 1c, pg. 4).
6.
Measure output voltage before connecting cameras/devices. This helps avoid potential damage.
7. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 1c, pg. 4).
8.
Connect the power output of terminals marked [+ 1 --- ] to the power input of device (Fig. 1b, pg. 4). Repeat this step for each additional de
9. Upon completion of wiring, set illuminated master power disconnect circuit breaker to the
ON (RESET) position (Fig. 1c, pg. 4).
rounded AC receptacle.
vice (Outputs 2-16).
- 2 - Vertiline33D/VertiLine33TD/Vertiline63D/VertiLine63TD
10. The power LEDs on the faceplate for Outputs 1-8 will illuminate when AC power is present (Fig. 1a, pg. 4).
Note: If an
y of the power LEDs are not illuminated the cause may be due to the following: a. AC mains fail. b. Illuminated master power disconnect circuit breaker is OFF or tripped. c. One (1) or more power output PTCs are tripped due to a short circuit or overload condition.
To reset the PTC:
1. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 1d, pg. 4).
2.
Eliminate the trouble condition (short circuit or overload).
3. Allow 1 minute for PTC to cool off (reset).
4. Set illuminated master power disconnect circuit breaker to the (ON) position (Fig. 1d, pg. 4).
5.
All power LEDs will illuminate indicating power has been restored to all outputs (Fig. 1a, pg. 4).
Vertiline33D/VertiLine33TD/Vertiline63D/VertiLine63TD - 3 -
Loading...