Rack Mount Power Supplies
Installation Guide
Models Include:
Vertiline3D
- 12VDC @ 8 amp
- Eight (8) PTC protected outputs
Vertiline6D
- 24VDC @ 8 amp
- Eight (8) PTC protected outputs
Rev. 090710
More than just power.
TM
Overview:
Altronix Vertiline Rack Mount Power Supplies provide eight (8) filtered and electronically regulated power outputs in
a space saving 1U EIA 19” rack mount chassis. The units are available with either 12VDC or 24VDC power outputs.
Vertiline Rack Mount Power Supplies are also available in sixteen (16) outputs.
Specifica tions:
Agency Listing:
• CE European Conformity.
Input:
• 115VAC 60 Hz.
Output:
Vertiline3D:
• Eight (8) PTC protected 12VDC outputs rated @ 8 amp
total current max. (1.0 amp per device, 2.5 amp max.).
Vertiline6D:
• Eight (8) PTC protected 24VDC outputs rated @ 8 amp
total current max. (1.0 amp per device, 2.5 amp max.).
• Filtered and electronically regulated outputs.
Features:
• Eight (8) power LED indicators.
• Illuminated master power disconnect circuit breaker
with manual reset.
• IEC 320 - 3-wire grounded line cord (detachable).
• Removable terminal blocks with locking screw flange.
Mechanical:
• Units can be rack, wall or shelf mounted.
• Modular 1U standard EIA 19” rack mount chassis.
• Enclosure Dimensions (H x W x D approx.):
1.625” x 19.125” x 8.5” (41.3mm x 486mm x 216mm).
Eight (8) Output Rack Mount Configuration Reference Chart:
Total Output
Altronix
Model Number
Vertiline3D
Output
Voltage
12VDC 8 amp 8 PTC 2.5 amp 1.5 amp
Current
(Power)
Number of
Outputs
PTC Output
Protection
Current (max.
per output)
115VAC 60Hz
Input Current
Vertiline6D
24VDC 8 amp 8 PTC 2.5 amp 3 amp
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This
installation should be made by qualified service personnel and should conform to all local codes and in
accordance with the National Electrical Code.
Installation Instructions:
1. Attach mounting brackets to Vertiline unit for desired rack or wall mount installation (Figs. 3-4, pg. 7).
Affix rubber pads to Vertiline for shelf installation (Fig. 5, pg. 7).
2. Secure the unit into rack, mount unit to wall or place unit on a shelf as desired (unit should be spaced at least 3”
from any video monitors). When installing the unit in a rack, allow for one half U spacing above the unit
for ventilation.
3. Insert and secure removable terminal blocks to unit (Fig. 1e, pg. 4).
4. Plug the grounded AC line cord (included) into the IEC 320 connector of the Vertiline unit (Fig. 1d, pg. 4).
Insert the plug end of the line cord into a grounded AC, receptacle.
5. Set illuminated master power disconnect circuit breaker to the (ON) position (Fig. 1c, pg. 4).
6. Measure output voltage before connecting devices. This helps avoiding potential damage.
7. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 1c, pg. 4).
8. Connect the power output of terminals marked [+ 1 --- ] to the power input of device (Fig. 1b, pg. 4).
Repeat this step for each additional device (Outputs 2-8).
9. Upon completion of wiring, set illuminated master power disconnect circuit breaker to the
ON (RESET) position (Fig. 1c, pg. 4).
- 2 - Vertiline3D/VertiLine6D
10. The power LEDs on the faceplate for Outputs 1-8 will illuminate when AC power is present (Fig. 1a, pg. 4).
Note: If any of the power LEDs are not illuminated the cause may be due to the following:
a. AC mains fail.
b. Illuminated master power disconnect circuit breaker is OFF or tripped.
c. One (1) or more power output PTCs are tripped due to a short circuit or overload condition.
To reset the PTC:
1. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 1c, pg. 4).
2. Eliminate the trouble condition (short circuit or overload).
3. Allow 1 minute for PTC to cool off (reset).
4. Set illuminated master power disconnect circuit breaker to the (ON) position (Fig. 1c, pg. 4).
5. All power LEDs will illuminate indicating power has been restored to all outputs (Fig. 1a, pg. 4).
Vertiline3D/VertiLine6D - 3 -