Altronix VertiLine246D, VertiLine246, VertiLine24 Installation Guide

CCTV Rack Mount Power Supplies
Installation Guide
Models Include:
Vertiline24 Vertiline24D
- 24VAC or 28VAC @ 10A - 24VAC or 28VAC @ 10A
- Twenty-four (24) fuse protected outputs - Twenty-four (24) PTC protected outputs
Vertiline246 Vertiline246D
- 24VAC or 28VAC @ 14A - 24VAC or 28VAC @ 14A
- Twenty-four (24) fuse protected outputs - Twenty-four (24) PTC protected outputs
Rev. 031808
TM
Overview:
Altronix Vertiline CCTV Rack Mount Power Supplies provide 24 power outputs in a space saving 1U EIA 19” rack mount chassis which may be rack, wall or shelf mounted. The units feature individually selectable 24VAC and/or 28VAC power outputs with surge suppression. Vertiline CCTV Rack Mount Power Supplies are also available in eight (8) and sixteen (16) output models with various power ratings.
Specifications:
Input:
• Selectable 115VAC 60 Hz or 240VAC 50/60 Hz input.
Output:
• Twenty-four (24) individually selectable 24VAC or 28VAC power outputs with OFF position.
• Twenty-four (24) external blade fuse or PTC protected outputs.
• Surge suppression.
Features:
• Twenty-four (24) power LED indicators.
Features (cont’d):
• Removable terminal blocks with locking screw flange.
• Illuminated master power disconnect circuit breaker with manual reset.
• IEC 320 - 3-wire grounded line cord (detachable).
Mechanical:
• Units can be rack, wall or shelf mounted.
• Modular 1U standard EIA 19” rack mount chassis
• Enclosure Dimensions (H x W x D approx.):
1.625” x 19.125” x 8.5” (41.3mm x 486mm x 216mm).
Twenty-four (24) Output Rack Mount Configuration Reference Chart:
Altronix Model Number
Vertiline24
Vertiline24D
Vertiline246
Vertiline246D
Output
Voltage (VAC)
24VAC or
28VAC
24VAC or
28VAC
24VAC or
28VAC
24VAC or
28VAC
Total Output
Current (Power)
Number of Outputs
10A 24
10A 24
14A 24
14A 24
Fused -- 3A 3A
Fused -- 3A 3A
Output Protection
Class 2 Rated Power-
Limited Output Protection
Current
(max. per output)
-- PTC 2.5A --
-- PTC 2.5A --
Fuse Rating
Main Fuse Rating
10A 3A 1.6A
15A 4A 2.5A
115VAC 60Hz Input
Current
230VAC 50/60Hz
Input Current
Agency Listings
UL Listings and
File Numbers
UL Listed for
Commercial
CCTV
Equipment
(UL 2044).
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This installation should be made by qualified service personnel and should conform to the National Electrical Code and all local codes.
Installation Instructions:
1. Set the input voltage selector switch located on the left side of the Vertiline unit (facing front panel) for 115VAC or 230VAC operation (Fig. 1c, pg. 4).
2. Attach mounting brackets to Vertiline unit for rack or wall mount installation (Figs. 4-5, pg. 7). Affix rubber pads to Vertiline for shelf installation (Fig. 6, pg. 7).
3. Secure the unit in a rack, mount unit to a wall or place unit on a shelf as desired (unit should be spaced at least 3” from any video monitors). When installing the unit in a rack, allow for one half of a U spacing above the unit for ventilation.
4. Plug the grounded AC line cord (included) into the IEC 320 connector of the Vertiline unit (Fig. 1g, pg. 4). Insert the plug end of the line cord into a grounded AC receptacle.
5. Set illuminated master power disconnect circuit breaker to the (ON) position (Fig. 3, pg. 6).
6. Select 24VAC or 28VAC power output for cameras 1-24 with the corresponding voltage adjustment switches (Fig. 1b, pg. 4).
- 2 - Vertiline24
7. Measure output voltage before connecting cameras. This helps avoiding potential damage. All terminals with common suffix (P) “1P, 2P ...” are the same polarity.
8. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 3, pg. 6).
9. Connect the power outputs of terminals marked [1P & 1N] to the power inputs of camera 1 (Fig. 2, pg. 5). Repeat this step for each additional camera (Outputs 2-24). After wiring is completed, insert terminal block into the corresponding connector and secure by tightening the screws.
10. Upon completion of the wiring, set illuminated master power disconnect circuit breaker to the ON (RESET) position (Fig. 3, pg. 6).
11. The power LEDs (Green) on the faceplate for Outputs 1-24 will illuminate when AC power is present (Fig. 1a, pg. 4). If any of these LEDs are off, a loss of AC power output may be due to a blown fuse or a tripped PTC caused by a short circuit or overload condition. If all of the LEDs are OFF, there may be a complete loss of supply power to the Vertiline unit or the illuminated master power disconnect circuit breaker is in the OFF position or the main fuse 1-12 or 13-24 is blown (Fig. 1d, pg. 4).* To restore the power output for Vertiline24 or Vertiline246: 1- Switch corresponding output voltage switch to the OFF position (Fig. 1b, pg. 4). 2- Eliminate the trouble condition. 3- Replace the corresponding automotive blade fuse.* 4- Switch output voltage switch to the 24VAC or 28VAC position as desired (Fig. 1b, pg. 4). To restore the power output for Vertiline24D or Vertiline246D: 1- Switch corresponding output voltage switch to the OFF position (Fig. 1b, pg. 4). 2- Eliminate the trouble condition. 3- Allow 1 minute for PTC to cool off. 4- Switch output voltage switch to the 24VAC or 28VAC position as desired (Fig. 1b, pg. 4).
*Note: Replace fuses with same type and rating:
Output fuses are rated @ 3A for all models. Main fuse ratings: 10A for Vertiline24 and Vertiline24D. 15A for Vertiline246 and Vertiline246D.
Automotive Blade Fuse
Vertiline24 - 3 -
AC POWER
115VAC 220VAC
AC POWER
1c - Input Voltage
Switch: Selects
115VAC/230VAC
50/60Hz (switch is
located on the left
side of the unit).
1b - Output voltage switches:
Selects 24VAC or 28VAC
or OFF for each output.
22 23 24
21
OFF
28VAC
24VAC
18 19 20
17
14 15 16
13
OFF
28VAC
24VAC
10 11 12
9
OFF
28VAC
24VAC
1234
5678
9101112
13141516
P
N P
N P
N P
N
P
N P
N P
N P
N
P
N P
N P
N P
N
1-12
Main Fuse
P
N P
N P
N P
N
1g - IEC 320
Connector: 115VAC
60Hz/230VAC 50/60Hz
(grounded line
cord included).
1f - Output Fuses:
Automotive blade fuses.
1e - Power
Outputs: 24VAC
or 28VAC.
P
1234
N P
N P
N P
N
P
5678
N P
N P
N P
N
P
9101112
N P
N P
N P
N
1-12
Main Fuse
P
13141516
N P
N P
N P
N
1d - Main Fuse:
Protects the
transformer
1a - LED(s) 1-24:
Power LED indicators.
Vertiline24, Vertiline24D, Vertiline246
or Vertiline246D (front)
678
5
234
1
RESET
17181920
OFF
28VAC
24VAC
21222324
OFF
Vertiline24 or Vertiline246 (rear)
P
N P
N P
N P
N
P
N P
N P
N P
N
13-24
Main Fuse
against overload.
Vertiline24D or Vertiline246D (rear)
P
17181920
N P
N P
N P
N
P
21222324
N P
N P
N P
N
13-24
Main Fuse
Vertiline24D and Vertiline246D do not have output fuses on the rear of the rack mount
Fig. 1
- 4 - Vertiline24
chassis. The output PTCs are located on the inside of the rack mount chassis.
AC POWER
22 23 24
21
28VAC
18 19 20
17
14 15 16
13
28VAC
10 11 12
Typical Hookup:
9
28VAC
1234
OFF
24VAC
5678
9101112
OFF
24VAC
13141516
OFF
24VAC
P
N P
N P
N P
N
P
N P
N P
N P
N
P
N P
N P
N P
N
1-12
Main Fuse
P
N P
N P
N P
N
Fig. 2
RESET
678
5
OFF
28VAC
24VAC
234
1
OFF
17181920
21222324
P
N P
N P
N P
N
P
N P
N P
N P
N
13-24
Main Fuse
Vertiline24 - 5 -
The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open enclosure. There are no user serviceable parts inside. Refer servicing to qualified service personnel.
1U EIA 19” Rack Mount Chassis Mechanical Drawing and Dimensions (H x W x D):
1.625” x 19.125” x 8.5” (41.3mm x 486mm x 216mm)
REAR
17.125”
1.625”
(41.275mm)
Main Fuse
13-24
NPNPNPN
21222324
P
NPNPNPN
17181920
P
(434.97mm)
13141516
Main Fuse
1-12
NPNPNPN
P
TOP and BOTTOM
NPNPNPN
9101112
P
NPNPNPN
5678
P
NPNPNPN
1234
P
AC POWER
(215.9mm)
0.95”
(24.13mm)
8.5”
RESET
FRONT
234
1
OFF
678
5
28VAC
OFF
24VAC
10 11 12
9
28VAC
OFF
24VAC
(485.775mm)
19.125”
28VAC
OFF
24VAC
13
14 15 16
(ON)
17
18 19 20
22 23 24
21
28VAC
OFF
24VAC
Fig. 3
Power switch with built-in circuit breaker: OFF position - Switch not illuminated. Outputs not powered. RESET (ON) position - Switch illuminated. Outputs powered. Circuit breaker tripped - Switch not illuminated. Power LEDs on faceplate are not illuminated. Outputs not powered. To reset circuit breaker set power switch to the ON (RESET) position (Fig. 3, pg. 6).
- 6 - Vertiline24
Mounting Options:
Rack Mount Installation
1. Remove factory installed screws from both sides of rack chassis (Fig. 4a).
2. Install mounting brackets (A) on the left and right sides of rack chassis using the two (2) flat head screws (B) (included) (Fig. 4b).
3. Place unit into the desired EIA 19” rack position and secure with mounting screws (not included) (Fig. 4c).
Fig. 4
Fig. 4a
Top Top
Fig. 4b
Fig. 4c
Top
Front
Front Left
B
Left
Front Left
Remove
A
Wall Mount Installation
1. Install mounting brackets (A) on the left and right sides of rack chassis using two (2) flat head screws (B) (included) (Fig. 5a).
2. Place unit at the desired location and secure with mounting screws (not included) (Fig. 5b).
Caution: It is necessary to make sure that mounting screws are securely fastened to a beam when installing.
Fig. 5
Fig. 5a
Fig. 5b
B
A
Shelf Installation
1. Position and affix rubber pads (C) (included) at each corner on the bottom of the unit (Fig. 6).
2. Place unit in the desired location.
Fig. 6
Left Side
C
Vertiline24 - 7 -
Rubber Pad
Mounting Hardware (Included):
A
Two (2) mounting brackets
Six (6) flat head screws
B
for mounting brackets.
C
Four (4) rubber pads.
Notes:
Altronix is not responsible for any typographical errors.