Edge of
Enclosure
to Access Control Panel
or U.L. Listed
Reporting Device
Enclosure
Honeywell
model # 112
Tamper Switch
or equivalent
(provided)
Rev. 062416
Installation Guide
Versatile Access Power and Integration Enclosures
Trove2SH2 TSH2
- Trove2 enclosure with - Altronix/Software House backplane only
Altronix/Software House backplane (TSH2)
Trove2SH2 accommodates various combinations of Software House boards with or without Altronix
power supplies and accessories for access systems.
Specifications:
Overview:
• 19 Gauge grey enclosure with ample knockouts for convenient access.
Enclosure Dimensions (H x W x D): 27.25” x 21.75” x 6.5” (692.15mm x 552.45mm x 165.1mm).
Trove2SH2
Metal or Nylon Standoff
- Trove2 enclosure with TSH2 Altronix/Software House backplane.
• Includes: tamper switch, cam lock, lock nuts and mounting hardware.
TSH2
- TSH2 Altronix/Software House backplane.
5/16” Pan Head Screw
Lock Nut
• 19 Gauge backplane.
• Includes mounting hardware.
Dimensions (H x W x D): 25.375” x 19.375” x 0.3125” (644.525mm x 492.125mm x 7.9mm).
Backplane accommodates a combination of the following:
• Two (2) AL400ULXB2, AL600ULXB, AL1012ULXB, AL1024ULXB2,
eFlow4NB, eFlow6NB, eFlow102NB or eFlow104NB.
• One (1) ACM4(CB), ACM8(CB), MOM5, PD4UL(CB), PD8UL(CB), PDS8(CB), VR6.
• One (1) iStar Ultra GCM and two (2) iStar Ultra ACM.
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all
local codes and authorities having jurisdiction. Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure.
Install three upper fasteners and screws in the wall with the screw heads protruding.
Place the enclosure’s upper keyholes over the three upper screws, level and secure.
Mark the position of the lower three holes. Remove the enclosure.
Drill the lower holes and install the three fasteners. Place the
enclosure’s upper keyholes over the three upper screws.
Install the three lower screws and make sure to
tighten all screws.
3. Mount UL Listed tamper switch (Included)
(Ademco model 112 or equivalent) in desired location,
opposite hinge. Slide the tamper switch bracket onto
the edge of the enclosure approximately 2” from the
right side (Fig. 1, pg. 1). Connect tamper switch
wiring to the Access Control Panel input or the
appropriate UL Listed reporting device.
To activate alarm signal open the door of the enclosure.
4. Mount Altronix/Software House boards to backplane,
refer to page 2.
Fig. 1
Trove2SH2/TSH2 - Altronix/Software House - 1 -
TSH2: Configuration of Altronix Power Supply
and/or Sub-Assembly Boards and Software House Boards
1. Fasten standoffs (provided) to pems that match the hole pattern for Altronix Power Supply/Chargers
or Altronix Sub-Assembly boards (Fig. 2, pg. 2).
Fasten metal standoffs in the correct locations to provide proper grounding, see below (Fig. 2, pg. 2).
2. Mount boards to standoffs utilizing 5/16” pan head screws (provided) (Fig. 2, pg. 2).
3. Align the Software House boards on the backplane to match the boards’ mounting holes
with pems provided.
4. Fasten standoffs (provided) to pems that match the hole pattern for Software House
iStar Ultra GCM and iStar Ultra ACM boards.
5. Mount Software House boards to standoffs utilizing 5/16” pan head screws (provided) (Fig. 2, pg. 2).
Note: Software House iStar Ultra ACM boards have one (1) USB port each.
Please orient boards in the appropriate position according to the Fig. 2 below.
6. Fasten backplane to Trove2 enclosure utilizing lock nuts (provided).
Fig. 2
Altronix
Power Supply
iStar
Ultra GCM
Metal Standoff Placement
Altronix
Power Supply or
Sub-Assembly
Metal Standoff Placement
iStar Ultra ACM
iStar Ultra ACM
- 2 - Trove2SH2/TSH2 - Altronix/Software House
USB PORT
USB PORT