![](/html/9e/9ec7/9ec72cf3abeca2700a68d992e3924ee237dc79bd0ee9c5754397adc1026be6c1/bg1.png)
Access & Power Integration
Trove1SA1
- Trove1 enclosure with Altronix/SALTO backplane (TSA1)
TSA1
- Altronix/SALTO backplane only
Installation Guide
All registered trademarks are property of their respective owners. More than just power.™
Rev. TSA061318
Installing Company: _____________________ Service Rep. Name: __________________________________________
Address: ________________________________________________________ Phone #: _________________________
![](/html/9e/9ec7/9ec72cf3abeca2700a68d992e3924ee237dc79bd0ee9c5754397adc1026be6c1/bg2.png)
Overview:
Edge of
Enclosure
to Access Control Panel
or U.L. Listed
Reporting Device
Enclosure
Honeywell
model # 112
Tamper Switch
or equivalent
(provided)
Altronix Trove1SA1 accommodates combinations of SALTO boards with or without Altronix power supplies and sub-assemblies for
access systems.
Specifications:
• 16 Gauge grey backplane and enclosure with ample knockouts for convenient access.
Trove1SA1
Trove1 enclosure with TSA1 Altronix/SALTO backplane
• Includes: tamper switch, cam lock, lock nuts, and mounting hardware.
Enclosure Dimensions (H x W x D): 18” x 14.5” x 4.625” (457mm x 368mm x 118mm).
TSA1
Altronix/SALTO backplane only
• Includes mounting hardware.
Dimensions (H x W x D): 16.625” x 12.5” x 0.3125” (422.3mm x 317.5mm x 7.9mm).
TSA1 accommodates a combination of the following:
• Altronix Modules:
One (1) AL400ULXB2, AL600ULXB, AL1012ULXB, AL1024ULXB2, eFlow4NB, eFlow6NB, eFlow102NB or eFlow104NB.
Up to two (2) PD4UL/PD4ULCB, PD8UL/PD8ULCB, MOM5, PDS8(CB) or VR6.
• SALTO Modules:
Up to four (4) CU42E0 modules.
Installation Instructions for Trove1:
1. Remove backplane from enclosure prior to mounting (do not discard hardware).
2. Mark and predrill holes on the wall to line up with the top two keyholes in the enclosure. Install two upper fasteners and screws in
the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two upper screws; level and secure.
Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the two fasteners. Place the enclosure’s
upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch (Honeywell Model 112 or equivalent) in desired location, opposite hinge.
Slide the tamper switch bracket onto the edge of the enclosure approximately 2” from the right side (Fig. 1, pg. 1).
Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device.
To activate alarm signal open the door of the enclosure.
4. Mount Altronix/SALTO modules to TSA1 backplane, refer to page 3.
Fig. 1
- 2 - Trove1SA1 / TSA1