• 16 Gauge enclosure with ample knockouts for convenient access.
Enclosure Dimensions (H x W x D): 27.25” x 21.75” x 6.5” (692.15mm x 552.5mm x 165.1mm).
TAG2 - Altronix/AMAG M4000 backplane only
• Includes mounting hardware.
Dimensions (H x W x D): 25.375” x 19.375” x 0.3125” (644.5mm x 482.6mm x 7.9mm).
Trove2AM2 - Trove2 enclosure with TAM2 Altronix/AMAG M2150 backplane
Trove2AM2 accommodates a combination of the following:
• Altronix Modules:
- Up to two (2) eFlow4NB, eFlow6NB, eFlow102NB, eFlow104NB or PoE201.
- Up to two (2) LINQ8PD/ LINQ8PDCB, ACM8/ACM8CB, ACMS8/ACMS8CB, ACM4/ACM4CB, MOM5, PD4UL/PD4ULCB,
PD8UL/PD8ULCB, PDS8/PDS8CB, or VR6.
• AMAG Modules:
- One (1) M2150-2DBC, M2150-4DBC or M2150-8DBC modules.
- One (1) M2150-2DC, M2150-4DC or M2150-AC244 modules.
• 16 Gauge enclosure with ample knockouts for convenient access.
Enclosure Dimensions (H x W x D): 27.25” x 21.75” x 6.5” (692.2mm x 552.5mm x 165.1mm).
TAM2 - Altronix/AMAG M2150 backplane
• 16 Gauge backplane.
• Includes mounting hardware.
Dimensions (H x W x D): 25.375” x 19.375” x 0.3125” (644.6mm x 492.1mm x 7.9mm).
• 16 Gauge enclosure with ample knockouts for convenient access.
Enclosure Dimensions (H x W x D): 36.12” x 30.12” x 7.06” (917.5mm x 768.1mm x 179.3mm).
TAM3 - Altronix/AMAG M2150 / M4000 backplane
• 16 Gauge backplane.
• Includes mounting hardware.
Dimensions (H x W x D): 34.0” x 28.0” x 0.3125” (863.6mm x 711.2mm x 7.9mm).
Agency Listings:
• UL 294 - 6th edition: Line Security I, Destructive Attack I, Endurance IV, Stand-by Power II*.
* Stand-by Power Level I if no battery is supplied.
• This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme á la norme NMB-003 du Canada.
• CE European Conformity.
- 2 - Trove2AG2 / Trove2AM2 / Trove3AM3
Installation Instructions for Trove2 / Trove3:
Tamper Switch
(provided)
To Access Control Panel or
UL Listed Reporting Device
Edge of
Enclosure
Enclosure
1. Remove backplane from enclosure prior to mounting (do not discard hardware).
2. Mark and predrill holes in the wall to line up with the top keyholes in the enclosure. Install the upper fasteners and screws in the wall.
with the screw heads protruding. Place the enclosure’s upper keyholes over the screws; level and secure. Mark the position of the
lower holes. Remove the enclosure. Drill the lower holes and install the fasteners. Place the enclosure’s upper keyholes over the
upper screws. Install the lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 10, 12).
3. Mount included UL Listed tamper switch(es) (Altronix Model TS112 or equivalent) in desired location, opposite hinge.
Slide the tamper switch bracket onto the edge of the enclosure approximately 2” from the right side (Fig. 1, pg. 3).
Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device.
To activate alarm signal open the door of the enclosure.
4. Mount Altronix/AMAG boards to backplane, refer to pages 4-6.
Fig. 1
Hardware:
Metal or Nylon Spacer | 5/16” Pan Head Screw | Lock Nut
Trove2AG2 / Trove2AM2 / Trove3AM3 - 3 -
TAG2: Configuration of Altronix Power Supply and/or Sub-Assembly Boards and
AMAG M4000 Boards
1. Fasten spacers (provided) to pems that match the hole pattern for Altronix power supply/chargers and sub-assemblies (Fig. 2, pg. 4).
Fasten metal spacers in the correct locations to provide proper grounding, see below (Fig. 2, pg. 4).
Fasten spacers (provided) to pems that match the hole pattern for AMAG M4000 modules.
2. Mount boards to spacers utilizing 5/16” pan head screws (provided) (Fig. 2, 2a, pg. 4).
eFlow4NB, eFlow6NB, eFlow102NB, eFlow104NB, ACM8/ACM8CB, ACMS8/ACMS8CB or PoE201A
NetWaySP4BB
LINQ8PD/ LINQ8PDCB, ACM4/ACM4CB, MOM5, PD4UL/PD4ULCB, PD8UL/PD8ULCB, PDS8/PDS8CB, or VR6C
AMAG M4000 BoardsD
Fig. 2
D
A
Metal Spacer Placement
A
Metal Spacer Placement
A
B
C
D
D
CC
Spacer
Fig. 2a
Pem
Pan Head
Screw
- 4 - Trove2AG2 / Trove2AM2 / Trove3AM3
Power Supply or
Sub-Assembly
Backplane
TAM2: Configuration of Altronix Power Supply and/or Sub-Assembly Boards and
AMAG M2150 Boards
1. Fasten spacers (provided) to pems that match the hole pattern for Altronix Power Supply/Chargers or Altronix Sub-Assembly boards
(Fig. 3, 3a, pg. 5). Fasten metal spacers in the correct locations to provide proper grounding, see below (Fig. 3, pg. 5).
2. Mount boards to spacers utilizing 5/16” pan head screws (provided) (Fig. 3, pg. 5).
3. Align the AMAG boards on the backplane to match the boards’ mounting holes with pems provided.
4. Fasten spacers (provided) to pems that match the hole pattern for AMAG M2150 boards.
5. Mount AMAG boards to spacers utilizing 5/16” pan head screws (provided) (Fig. 3, pg. 5).
Note: AMAG M2150 boards have specific markings. Please orient boards in the appropriate position according to the Fig. 3 below.
6. Fasten backplane to Trove2 enclosure utilizing lock nuts (provided).
BoardsPem Mounting
eFlow4NB, eFlow6NB, eFlow102NB, eFlow104NB, ACM8/ACM8CB, ACMS8/ACMS8CB or PoE201
LINQ8PD/ LINQ8PDCB, ACM4/ACM4CB, MOM5, PD4UL/PD4ULCB, PD8UL/PD8ULCB, PDS8/PDS8CB, or VR6
AMAG M2150-AC24/4, M2150-4DC Boards
AMAG M2150-2DC Board
AMAG M2150-2DBC Board
AMAG M2150-4DBC, M2150-8DBC Boards
Fig. 3
A
B
C
D
E
F
C
Fig. 3a
D
A
Power Supply or
Sub-Assembly
Metal Spacer Placement
Pan Head
Screw
Pem
Spacer
Backplane
B
A
READER 1
Metal Spacer Placement
A
READER 1
B
F
E
COM C
RS232
Trove2AG2 / Trove2AM2 / Trove3AM3 - 5 -
TAM3: Configuration of Altronix Power Supply and/or Sub-Assembly Boards and
AMAG M2150 / M4000 Boards
1. Fasten spacers (provided) to pems that match the hole pattern for Altronix power supply/chargers and sub-assemblies (Fig. 4, pg. 6).
Fasten metal spacers in the correct locations to provide proper grounding, see below (Fig. 4, pg. 6).
Fasten spacers (provided) to pems that match the hole pattern for AMAG boards.
2. Mount boards to spacers utilizing 5/16” pan head screws (provided) (Fig. 4, 4a, pg. 6).
eFlow4NB, eFlow6NB, eFlow102NB, eFlow104NB, ACM8/ACM8CB, ACMS8/ACMS8CB or PoE201
LINQ8PD/ LINQ8PDCB, ACM4/ACM4CB, MOM5, PD4UL/PD4ULCB, PD8UL/PD8ULCB, PDS8/PDS8CB, or VR6
AMAG M2150-DBU
AMAG M2150-AC24/4, M2150-4DC
AMAG M4000
AMAG M2150-4DBC, M2150-8DC, M2150-8DBC
A
B
C
D
E
F
Fig. 4
A
A
A
Metal Spacer Placement
Metal Spacer Placement
B
C
EE
D
C
Fig. 4a
F
Pem
Spacer
Pan Head
Screw
F
Power Supply or
Sub-Assembly
Backplane
A B
EE
B
D
B
- 6 - Trove2AG2 / Trove2AM2 / Trove3AM3
Notes:
Trove2AG2 / Trove2AM2 / Trove3AM3 - 7 -
eFlow Power Supply/Chargers can be Controlled and Monitored while
Reporting Power/Diagnostics from Anywhere over the Network...
LINQ2 - Network Communication Module
LINQ2 provides remote IP access to real-time data from eFlow power supply/chargers to help keep
systems up and running at optimal levels. It facilitates fast and easy installation and set-up, minimizes system downtime, and eliminates unnecessary service calls, which helps reduce Total Cost
of Ownership (TCO) - as well as creating a new source of Recurring Monthly Revenue (RMR).
LINQ2
Features:
- UL Listed in the U.S. and Canada.
- Local or remote control of up to (2) two Altronix eFlow power output(s) via LAN and/or WAN.
- Monitor real time diagnostics: DC output voltage, output current, AC & battery status/service, input trigger state change,
output state change and unit temperature.
- Access control and user managment: Restrict read/write, Restrict users to specific resources
- Two (2) integral network controlled Form “C” Relays.
- Three (3) programmable input triggers: Control relays and power supplies via external hardware sources.
- Email and Windows Dashboard notifications
- Event log tracks history.
- Secure Socket Layer (SSL).
- Programmable via USB or web browser - includes operating software and 6 ft. USB cable.
LINQ2 Mounts Inside any Trove Enclosure
LINQ2 Module
Network Connection:
Installation, Programming
and Monitoring
Altronix eFlow
Power Supply
- 8 - Trove2AG2 / Trove2AM2 / Trove3AM3
0.45” (11.4mm)0.45” (11.4mm)
TAG2 / TAM2 Dimensions
25.375” x 19.375” x 0.3125” (644.5mm x 482.6mm x 7.9mm).
19.375” (492.1mm)
2.2” (55.9mm)2.2” (55.9mm)
25.375” (644.6mm)
0.156”
( 3.96mm)
16.25” (412.8mm)
12.625” (320.7mm)
8.5” (215.9mm)
1.0” (25.4mm)
1.0” (25.4mm)
7.5” (190.5mm)7.5” (190.5mm)
9.2” (233.7mm)9.2” (233.7mm)
Trove2AG2 / Trove2AM2 / Trove3AM3 - 9 -
6.25” (158.8mm)
1.25” (31.8mm)
Trove2 Enclosure Dimensions (H x W x D approximate):
27.25” x 21.75” x 6.5” (692.15mm x 552.5mm x 165.1mm)
21.50” (546.1mm)
2.00” (50.8mm)2.00” (50.8mm)
1.25”
(31.8mm)
1.5”
(38.1mm)
5.25” (133.35mm)
0.5625” (14.3mm)
3.5”(88.9mm) 3.5”(88.9mm)
(45mm)
2.415” (61.3mm)
19.80” (502.9mm)
1.77”
5.25” (133.35mm)
0.685” (17.4mm)
Knockouts
1.125” (28.3mm)
0.885” (22.5mm)
6.25” (158.8mm)
2.00” (50.8mm)
6.75” (171.5mm)8.25” (209.5mm)
1.00” (25.4mm)
2.00” (50.8mm)
27” (685.8mm)
0.85” (21.6mm)
5.25” (133.4mm)5.25” (133.4mm)7.00” (177.8mm)
8.00” (203.2mm)
2.00” (50.8mm)
1.25” (31.8mm)
1.25” (31.8mm)
2.00” (50.8mm)
- 10 - Trove2AG2 / Trove2AM2 / Trove3AM3
0.45” (11.4mm)
TAM3 Dimensions
34” x 28” x 0.3125” (863.6mm x 711.2mm x 7.9mm)
28” (711.2mm)
2.5” (63.5mm)
0.156”
( 3.96mm)
34” (863.6mm)
2” (50.8mm)
13.5”
(342.9mm)
1.0” (25.4mm)
1.0” (25.4mm)
25” (635mm)
13.5” (342.9mm)
13.5”
(342.9mm)
Trove2AG2 / Trove2AM2 / Trove3AM3 - 11 -
Trove3 Enclosure Dimensions (H x W x D approximate):
(50.8mm)
1.25” (31.8mm)
2.00” (50.8mm)7.12” (222.3mm)
9.5” (241.3mm)9.5” (241.3mm)
36.12” x 30.125” x 7.06” (917.5mm x 768.1mm x 179.3mm)
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
web site: www.altronix.com | e-mail: info@altronix.com | Made in U.S.A.
IITrove2AG2/Trove2AM2/Trove3AM3 L17S
- 12 - Trove2AG2 / Trove2AM2 / Trove3AM3
MEMBER