![](/html/31/3161/316170fd515ed90cc6a88b8632e466c2a7f13d3f49151f8f86ec7f90eadb3cd7/bg1.png)
Rev. 053116
Installation Guide
Versatile Access Power and Integration Enclosures
Trove1C1 Trove2CV2
- Trove1 enclosure with - Trove2 enclosure with
Altronix/CDVI backplane (TC1) Altronix/CDVI backplane (TCV2)
TC1 TCV2
- Altronix/CDVI backplane only - Altronix/CDVI backplane only
Trove1C1 and Trove2CV2 accommodate various combinations of CDVI boards with or without
Altronix power supplies and accessories for access systems.
Specifications:
Overview:
• 19 Gauge grey enclosure with ample knockouts for convenient access.
Trove1C1
- Trove1 enclosure with TC1 Altronix/CDVI backplane.
• Includes: tamper switch, cam lock, lock nuts and mounting hardware.
Enclosure Dimensions (H x W x D): 18” x 14.5” x 4.6255” (457mm x 368mm x 118mm)
TC1
- TC1 Altronix/CDVI backplane.
• 19 Gauge backplane.
• Includes mounting hardware.
Dimensions (H x W x D): 16.625” x 12.5” x 0.3125” (422.275mm x 317.5mm x 7.9mm)
TC1 Backplane accommodates a combination of the following:
• One (1) AL400ULXB2, AL600ULXB, AL1012ULXB, AL1024ULXB2,
eFlow4NB, eFlow6NB, eFlow102NB or eFlow104NB.
• One (1) ACM4(CB), MOM5, PD4UL(CB), PD8UL(CB), PDS8(CB), VR6.
• Four (4) A22 modules.
Trove2CV2
- Trove2 enclosure with TCV2 Altronix/CDVI backplane.
• Includes: tamper switch, cam lock, lock nuts and mounting hardware.
Enclosure Dimensions (H x W x D): 27.25” x 21.75” x 6.5” (692.15mm x 552.45mm x 165.1mm)
TCV2
- TCV2 Altronix/CDVI backplane.
• 19 Gauge backplane.
• Includes mounting hardware.
Dimensions (H x W x D): 25.375” x 19.375” x 0.3125” (644.525mm x 492.125mm x 7.9mm)
TCV2 Backplane accommodates a combination of the following:
• Two (2) AL400ULXB2, AL600ULXB, AL1012ULXB, AL1024ULXB2,
eFlow4NB, eFlow6NB, eFlow102NB or eFlow104NB.
• One (1) ACM8(CB), or two (2) MOM5, PD4UL(CB), PD8UL(CB), PDS8(CB), VR6.
• Five (5) A22 modules.
Trove1C1/TC1/Trove2CV2/TCV2 - Altronix/CDVI - 1 -
![](/html/31/3161/316170fd515ed90cc6a88b8632e466c2a7f13d3f49151f8f86ec7f90eadb3cd7/bg2.png)
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all
Edge of
Enclosure
to Access Control Panel
or U.L. Listed
Reporting Device
Enclosure
Honeywell
model # 112
Tamper Switch
or equivalent
(provided)
Installation Instructions:
local codes and authorities having jurisdiction. Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
Trove1C1 (Fig. 5, pg. 5)
2.
Mark and predrill holes on the wall to line up with the top two keyholes in the enclosure.
Install two upper fasteners and screws in the wall with the screw heads protruding.
Place the enclosure’s upper keyholes over the two upper screws, level and secure.
Mark the position of the lower two holes. Remove the enclosure.
Drill the lower holes and install the two fasteners. Place the
enclosure’s upper keyholes over the two upper screws.
Install the two lower screws and make sure to
tighten all screws.
Trove2CV2 (Fig. 9, pg. 8)
Mark and predrill holes on the wall to line up with the
top three keyholes in the enclosure. Install three upper
fasteners and screws in the wall with the screw heads
protruding. Place the enclosure’s upper keyholes over
the three upper screws, level and secure. Mark the
position of the lower three holes. Remove the enclosure.
Drill the lower holes and install the three fasteners. Place the
enclosure’s upper keyholes over the three upper screws.
Install the three lower screws and make sure to tighten all screws.
3. Mount UL Listed tamper switch (Included)
(Ademco model 112 or equivalent) in desired location,
opposite hinge. Slide the tamper switch bracket onto
the edge of the enclosure approximately 2” from the
right side (Fig. 1, pg. 1). Connect tamper switch
wiring to the Access Control Panel input or the
appropriate UL Listed reporting device.
To activate alarm signal open the door of the enclosure.
4. Mount Altronix/CDVI modules to TC1 or TCV2 backplane,
refer to pages 3 and 6.
Fig. 1
Mounting Hardware:
Plastic Standoff
Metal Standoff
3/8” Pan Head Screw
- 2 - Trove1C1/TC1/Trove2CV2/TCV2 - Altronix/CDVI
![](/html/31/3161/316170fd515ed90cc6a88b8632e466c2a7f13d3f49151f8f86ec7f90eadb3cd7/bg3.png)
TC1: Configuration of Altronix Power Supply
and/or Sub-Assembly Boards and CDVI Modules
1. Fasten standoffs (provided) to pems that match the hole pattern for Altronix Power
Supply/Chargers or Altronix Sub-Assembly boards (Fig. 3, pg. 3).
Fasten metal standoffs in the correct locations to provide proper
grounding, see below (Fig. 3, pg. 3).
2. Mount boards to standoffs utilizing 5/16” pan head
screws (provided) (Fig. 3, pg. 3).
3. Mount appropriate CDVI A22 modules into the correct positions (Fig. 3, pg. 3).
by postioning standoffs over appropriate holes on the backplane and
depress down on board to secure standoff to the backplane (Fig. 2, pg. 3).
Note: CDVI A22 modules have one (1) RJ45 jack each. Please make sure that
they are mounted correctly, as shown in Fig. 3 below.
4. Fasten TC1 backplane to Trove1 enclosure utilizing pan head screws (provided).
Fig. 3 - Trove1C1/TC1 Configurations
Plastic Stand Off
pre-mounted into
CDVI Atrium modules
Insert into
Fig. 2
Metal
Standoff
Placement
Altronix
Power
Supply
Altronix
Sub-
Assembly
CDVI - A22 CDVI - A22CDVI - A22
RJ45 Jack RJ45 Jack RJ45 Jack
RJ45 JackRJ45 JackRJ45 Jack
CDVI - A22 CDVI - A22CDVI - A22
Trove1C1/TC1/Trove2CV2/TCV2 - Altronix/CDVI - 3 -