Altronix TROVE1PD1, TPD1 Installation Guide

Access & Power Integration
Trove1PD1
- Trove1 enclosure with Altronix/PDK backplane (TPD1)
TPD1
- Altronix/PDK backplane only
Installation Guide
All registered trademarks are property of their respective owners. More than just power.™
Rev. TPDK031418
Installing Company: _____________________ Service Rep. Name: __________________________________________
Overview:
Edge of
Enclosure
to Access Control Panel
or U.L. Listed
Reporting Device
Enclosure
Honeywell
model # 112
Tamper Switch
or equivalent
(provided)
Altronix Trove1PD1 accommodates various combinations of PDK boards with or without Altronix power supplies and sub-assemblies for access systems.
Specifications:
• 16 Gauge grey backplane and enclosure with ample knockouts for convenient access.
Trove1PD1
Trove1 enclosure with TPD1 Altronix/PDK backplane
• Includes: tamper switch, cam lock, lock nuts, and mounting hardware. Enclosure Dimensions (H x W x D): 18” x 14.5” x 4.625” (457mm x 368mm x 118mm).
TPD1
Altronix/PDK backplane only
• Includes mounting hardware. Dimensions (H x W x D): 16.625” x 12.5” x 0.3125” (422.3mm x 317.5mm x 7.9mm).
TPD1 accommodates a combination of the following:
Altronix Modules: Up to two (2) AL400ULXB2, AL600ULXB, AL1012ULXB, AL1024ULXB2, eFlow4NB, eFlow6NB, eFlow102NB or eFlow104NB.
PDK Modules: Three (3) PM-07-EIOE-E modules.
Installation Instructions for Trove1:
1. Remove backplane from enclosure prior to mounting (do not discard hardware).
2. Mark and predrill holes on the wall to line up with the top two keyholes in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two upper screws; level and secure. Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the two fasteners. Place the enclosure’s upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch (Honeywell Model 112 or equivalent) in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2” from the right side (Fig. 1, pg. 1). Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure.
4. Mount Altronix/PDK modules to TPD1 backplane, refer to page 3.
Fig. 1
- 2 - Trove1PD1 / TPD1
Loading...
+ 2 hidden pages