Access & Power Integration
Trove1M1WP
NEMA 4/IP 66 Rated outdoor enclosure with Altronix/Mercury backplane
Installation Guide
Rev. T1M1WP083018
Installing Company: _____________________ Service Rep. Name: __________________________________________
Address: ________________________________________________________ Phone #: _________________________
More than just power.™
Overview:
Altronix Trove1M1WP accommodates various combinations of Mercury boards with or without Altronix power supplies and sub-assemblies
for access systems in a NEMA 4/IP 66 Rated outdoor enclosure.
Specifications:
Trove1M1WP
Outdoor enclosure with TM1X Altronix/Mercury backplane.
Accommodates the following Mercury controllers:
EP1501, MR51e, MR50, EP1502, MR4502, MR52, MR16IN, MR16OUT, EP2500, MUX8
Accommodates the following Altronix power supplies and/or sub-assemblies:
eFlow or ULX Power Supply/Chargers, AL175ULB, T2428100,
ACM4, ACM4CB, VR6, PDS8, PDS8CB, PD4UL, PD4ULCB, PD8UL or PD8ULCB
• 16 Gauge Backplane (TM1X):
- Dimensions (H x W x D): 14.875” x 12.875” x 0.3125” (377.8mm x 327mm x 7.9mm).
• Enclosure (WP2):
- Hot compression molded, halogen free, self-extinguishing fiberglass reinforced polyester.
- Stainless steel continuous hinge and stainless steel padlockable latches.
- Dimensions (H x W x D): 17.53” x 15.3” x 6.67” (445.3mm x 388.6mm x 169.4mm).
• Includes mounting hardware.
See TM1X Position Charts on Pg. 3 for the list of compatible power supplies and sub-assemblies.
Battery Backup:
• Trove1M1WP enclosure accommodates up to two (2) 12VDC/7AH batteries.
Accessories
PMK2 Pole Mount Kit (order separately)
PMK2 pole mount kit is designed to simplify installation of outdoor units. It accommodates 2”- 8”(diameter) poles or
5” (127mm) square poles.
Kit includes:
- Two (2) powder coated steel mount brackets.
- Four (4) stainless steel bolts and lock washers.
- Two (2) wormgear quick release straps.
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI and with all local codes and authorities having
jurisdiction. Product is intended for indoor use only.
1. Remove backplane from enclosure prior to drilling. Do not discard hardware.
Note: Make sure that hardware will not interfere with components of the circuit board.
2. Mark and drill desired inlets on the enclosure to facilitate wiring. Maximum NEMA type 4X rated fittings to be used are 0.5”.
Follow manufacturer’s specifications for the appropriate size opening.
Note: Inlets for conduit fittings should only be made on the bottom of the enclosure.
UL Listed NEMA type 4X rated conduit connector/hubs shall be used for the appropriate size inlets.
3. Mounting NEMA4/4X rated enclosure (Enclosure Dimensions, pg. 8):
Wall mount: Mount unit in desired location. Mark and drill holes to line up with the top and bottom holes of the enclosure flange.
Secure enclosure with appropriate fasteners (e. g. screws and anchors; bolts and locking nuts, etc.) that are compatible
with mounting surface and are of sufficient length/construction to ensure a secure mount (Fig. 3, pg. 6).
Pole Mount: Refer to Figs. 4 - 8, pg. 6.
Note: All inlets for conduit fittings should be on the bottom of the enclosure.
4. To facilitate wire entry utilize weather-tight NEMA rated connectors, bushings, and cable.
- 2 - Trove1M1WP
Installation Instructions for Sub-Assemblies to Trove1M1WP/TM1X:
Altronix Power Supplies/Chargers and/or Sub-Assemblies:
1a. Power Supply/Charger:
Fasten two (2) nylon and two (2) metal standoffs (supplied) to pem location (1) (Fig. 1, pg. 4).
Secure board to standoffs using pan head screws (supplied) (Fig. 1a, pg. 4).
1b. T2428100 Transformer:
Position transformer on pem location (3) as shown in Fig. 2, pg. 5. Secure transformer to backplane using two (2) lock nuts (supplied).
2. Sub-Assemblies:
Fasten standoffs (supplied) to pem location (2) as shown on Fig. 1, 2, pg. 4, 5.
Secure boards to standoffs using pan head screws (supplied) (Fig. 1a, 2a, pg. 4, 5).
3. For detailed information about installing and connecting Altronix sub-assemblies refer to the individual Installation Guides.
Mercury Sub-Assemblies:
4. Fasten standoffs (supplied) to pem locations (A), (B), (C) or (D) as shown on Fig. 1, 2, pg. 4, 5 depending on the sub-assembly module.
5. Secure boards to standoffs using pan head screws (supplied).
6. Fasten backplane to WP2 enclosure utilizing provided hardware.
Position Chart for the Following Altronix Models:
Altronix Board Pem Mounting
AL400ULXB2, AL600ULXB, AL1012ULXB, AL1024ULXB2,
eFlow4NB, eFlow6NB, eFlow102NB, eFlow104NB
AL175ULB, ACM4, ACM4CB, VR6, PDS8, PDS8CB, PD4UL, PD4ULCB, PD8UL or PD8ULCB 2
T2428100 3
1
Position Chart for the Following Mercury Models:
Mercury Access Controller Pem Mounting
EP1502, EP4502, MR52, MR16IN, MR16OUT
EP2500, MUX8
EP2500, MUX8
EP1501, MR51e
A
B
C
D
Trove1M1WP - 3 -