![](/html/56/568f/568f3303704c26ed961d1b0c22ed707c48743384e53b30c0cd33feffb39899f7/bg1.png)
Access & Power Integration
Trove2HW2
- Trove2 enclosure with Altronix/Honeywell ProWatch/WinPak backplane (THW2)
THW2
- Altronix/Honeywell ProWatch/WinPak backplane only
Trove3HW3
- Trove3 enclosure with Altronix/Honeywell ProWatch/WinPak backplane (THW3)
THW3
- Altronix/Honeywell ProWatch/WinPak backplane only
Installation Guide
All registered trademarks are property of their respective owners. More than just power.™
Rev. THW2103017
Installing Company: _____________________ Service Rep. Name: __________________________________________
Address: ________________________________________________________ Phone #: _________________________
![](/html/56/568f/568f3303704c26ed961d1b0c22ed707c48743384e53b30c0cd33feffb39899f7/bg2.png)
Overview:
Edge of
Enclosure
to Access Control Panel
or U.L. Listed
Reporting Device
Enclosure
Honeywell
model # 112
Tamper Switch
or equivalent
(provided)
Trove2HW2 and Trove3HW3 accommodate various combinations of Honeywell ProWatch/WinPak boards with or without Altronix power
supplies and accessories for access systems.
Specifications:
Trove2HW2
- Trove2 enclosure with THW2 Altronix/Honeywell backplane.
• Includes: tamper switch, cam lock, mounting hardware.
• 16 Gauge grey enclosure with ample knockouts for
convenient access.
Enclosure Dimensions (H x W x D):
27.25” x 21.75” x 6.5” (692.2mm x 552.5mm x 165.1mm).
Accommodates up to four (4) 12VDC/7AH batteries.
THW2
- THW2 Altronix/Honeywell backplane.
• 16 Gauge backplane.
• Includes mounting hardware.
Dimensions (H x W x D):
25.375” x 19.375” x 0.3125” (644.6mm x 492.1mm x 7.9mm).
THW2 accommodates a combination of the following:
Altronix:
• Up to four (4) AL400ULXB2, AL600ULXB, AL1012ULXB,
AL1024ULXB2, eFlow4NB, eFlow6NB, eFlow102NB, or
eFlow104NB.
• Up to four (4) ACM8(CB) or ACM8S(CB).
• Up to three (2) ACM4(CB), MOM5, PD4UL(CB), PD8UL(CB),
PDS8(CB), or VR6.
Honeywell:
• Up to six (6) PRO32IC, PRO32R2, PRO32IN, PRO32OUT,
PW51KEN, PW6K1IC, PW6K1IN, PW6K1OUT,
PW6K1R2 modules.
• One (1) PRO32E1PS or PW6K2E2PS power supply.
• Up to two (2) PW6K1ICE or PW6K1R1E modules.
Trove3HW3
- Trove3 enclosure with THW3 Altronix/Honeywell backplane.
• Includes: two (2) tamper switches, cam lock, mounting hardware.
• 16 Gauge grey enclosure with ample knockouts for
convenient access.
Enclosure Dimensions (H x W x D):
36.12” x 30.125” x 7.06” (917.5mm x 768.1mm x 179.3mm).
Accommodates up to four (4) 12VDC/12AH batteries.
THW3
- THW3 Altronix/Honeywell backplane.
• 16 Gauge backplane.
• Includes mounting hardware.
Dimensions (H x W x D):
34” x 28” x 0.3125” (863.6mm x 711.2mm x 7.9mm).
THW3 accommodates a combination of the following:
Altronix:
• Up to four (4) AL400ULXB2, AL600ULXB, AL1012ULXB,
AL1024ULXB2, eFlow4NB, eFlow6NB, eFlow102NB, or
eFlow104NB.
• Up to four (4) ACM8(CB) or ACM8S(CB).
• Up to six (6) ACM4(CB), MOM5, PD4UL(CB), PD8UL(CB),
PDS8(CB), or VR6.
Honeywell:
• Up to nine (9) PRO32IC, PRO32R2, PRO32IN, PRO32OUT,
PW51KEN, PW6K1IC, PW6K1IN, PW6K1OUT,
PW6K1R2 modules.
• Up to two (2) PRO32E1PS or PW6K2E2PS power supplies.
• Up to two (2) PRO22MX8 modules.
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having
jurisdiction. Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws
in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper screws; level and secure.
Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install
the three fasteners. Place the enclosure’s upper keyholes over the three upper screws.
Install the three lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch(es) (Honeywell Model 112 or equivalent)
in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the
enclosure approximately 2” from the right side (Fig. 1, pg. 2). Connect tamper switch
wiring to the Access Control Panel input or the appropriate UL Listed reporting device.
To activate alarm signal open the door of the enclosure.
4. Mount Altronix/Honeywell boards to backplane, refer to pages 3-6.
Fig. 1
- 2 - TroveHW
![](/html/56/568f/568f3303704c26ed961d1b0c22ed707c48743384e53b30c0cd33feffb39899f7/bg3.png)
Installation Instructions for Altronix Power Supplies and Sub-Assemblies to THW2:
1. Fasten standoffs (provided) into pem configuration (A) or (B) of backplane (Fig. 2, pg. 2).
2. Mount boards to standoffs utilizing 5/16” pan head screws (provided) (Fig. 2a, pg. 2).
3. Mount backplane to enclosure with hardware.
Access Controller Position Chart for the Following Models:
Altronix Board Pem Mounting
Altronix Power Supply/Charger or
Sub-Assembly
A
Standoff
Fig. 2a
Pem
Altronix Sub-Assembly B
Fig. 2
Metal Standoff Placement
A
AB
Pan Head
Screw
Altronix
Power Supply or
Sub-Assembly
Backplane
Metal Standoff Placement
Metal Standoff Placement
Metal Standoff Placement
AB
AB
TroveHW - 3 -
![](/html/56/568f/568f3303704c26ed961d1b0c22ed707c48743384e53b30c0cd33feffb39899f7/bg4.png)
Installation Instructions for Honeywell PRO32E1PS or PW6K2E2PS to THW2:
1. Install four (4) mounting screws approximately halfway into mounting holes in the power supply’s frame.
2. Position the power supply over four (4) keyholes (B) on THW2 so the AC Input terminal marked [CN1] (smaller opening in the frame)
is positioned to the left.
3. Slide the power supply to the left until secure. Tighten the mounting screws.
Installation Instructions for Honeywell Access Controllers to THW2:
1. Fasten standoffs (provided) into pem configuration (A) or (C) of backplane (Fig. 3, pg. 4).
2. Mount boards to standoffs utilizing 5/16” pan head screws (provided) (Fig. 3a, pg. 4).
3. Mount backplane to enclosure with hardware.
Fig. 3a
Honeywell ProWatch/WinPak Power Supply or Access Controller
Position Chart for the Following Models:
Honeywell Board Pem Mounting
3200 Series or WIN-PAK Series A
PRO32E1PS or PW6K2E2PS B
PW6K1ICE or PW6K1R1E C
Fig. 3
Pan Head
Screw
Honeywell
Access Controller
Pem
Standoff
Backplane
B
A
A
A
C
A
A
A
C
- 4 - TroveHW