Access & Power Integration
T2SK7F8D
8 Door Kit with PTC Protected Outputs
Fully assembled kit includes:
- Trove2 enclosure with TSH2 Altronix/Software House backplane
- One (1) eFlow104NB - Power Supply/Charger
- One (1) ACM8CB - PTC Protected Access Power Controller
- One (1) VR6 - Voltage Regulator
- One (1) PDS8CB - Dual Input Power Distribution Module
- One (1) Rocker Switch Bracket with One (1) Rocker Switch
T3SK75F8D
8 Door Kit with PTC Protected Outputs
Fully assembled kit includes:
- Trove3 enclosure with TSH3 Altronix/Software House backplane
- One (1) eFlow104NB - Power Supply/Charger
- One (1) eFlow102NB - Power Supply/Charger
- One (1) ACM8CB - PTC Protected Access Power Controller
- One (1) PD8ULCB - PTC Protected Power Distribution Module
- One (1) Rocker Switch Bracket with Two (2) Rocker Switches
T3SK75F16D
16 Door Kit with PTC Protected Outputs
Fully assembled kit includes:
- Trove3 enclosure with TSH3 Altronix/Software House backplane
- One (1) eFlow104NB - Power Supply/Charger
- One (1) eFlow102NB - Power Supply/Charger
- Two (2) ACM8CB - PTC Protected Access Power Controllers
- One (1) PD8ULCB - PTC Protected Power Distribution Module
- One (1) Rocker Switch Bracket with Two (2) Rocker Switches
Installation Guide
All registered trademarks are property of their respective owners. More than just power.™
Rev. TSKD110817
Installing Company: _____________________ Service Rep. Name: __________________________________________
Address: ________________________________________________________ Phone #: _________________________
Overview:
Edge of
Enclosure
to Access Control Panel
or U.L. Listed
Reporting Device
Enclosure
Honeywell
model # 112
Tamper Switch
or equivalent
(provided)
Altronix Trove Software House kits are pre-assembled and consist of Trove enclosure with factory installed Altronix power supply/chargers and
sub-assemblies. These kits also accommodate various combinations of Software House boards for up to sixteen (16) doors in a single enclosure.
Configuration Chart:
Nominal DC Output Voltage Options
Maximum
Supply Current
for Main and
Aux. Outputs
on Power
Supply board
and ACM8CB
Access Power
Controller’s
outputs (A)
24VDC Output
Range (V)
Fail-Safe/Fail-Secure
Outputs (auto-resettable)
120VAC 60Hz Input
Current (A)
Current Per
ACM8CB Output (A)
Power Supply Board
Input Fuse Rating
Power Supply Board
Battery Fuse Rating
ACM8CB Board
Input Fuse Rating
ACM8CB Board
Output PTC Rating
PDS8 Board
Input PTC Rating
PDS8CB Board
Altronix
Model
Number
Power Supply 1 Power Supply 2
[DC] [AUX] [DC] [AUX]
12VDC Output
Range (V)
24VDC Output
Range (V)
12VDC Output
Range (V)
24VDC Output
Range (V)
12VDC Output
Range (V)
24VDC Output
Range (V)
12VDC Output
Range (V)
Output PTC Rating
T2SK7F8D
T3SK75F8D
T3SK75F16D
eFlow104NB N/A
----------
20.17-
26.4
----------
20.17-
26.4
eFlow104NB eFlow102NB
20.19-
----------
20.19-
26.4
----------
26.4
10.0-
13.2
eFlow104NB eFlow102NB
20.19-
----------
20.19-
26.4
----------
26.4
10.0-
13.2
----------
----------
----------
10.03-
13.2
10.03-
13.2
24VDC @ 9.2A 8 4.5 2.0 6.3A/250V
24VDC @ 9.2A 8 8.0 2.0
----------
24VDC @ 9.2A 16 8.0 2.0
----------
6.3A/250V
(eFlow104NB)
5A/250V
(eFlow102NB)
6.3A/250V
(eFlow104NB)
5A/250V
(eFlow102NB)
15A/
32V
15A/
32V
15A/
32V
10A/
2.0A 2.0A 2.0A
250V
10A/
2.0A ---------- ----------
250V
10A/
2.0A ---------- ----------
250V
Hardware and Accessories:
• Nylon standoffs - eighteen (18) for T2SK7F8D, forty-six (46) for T3SK75F8D or T3SK75F16D.
• 5/16” pan head screws - eighteen (18) for T2SK7F8D, forty-six (46) for T3SK75F8D or T3SK75F16D.
• Tamper switch (Honeywell Model 112 or equivalent) - one (1) for T2SK7F8D, two (2) for T3SK75F8D or T3SK75F16D.
• Cam lock.
• Battery leads.
Mechanical:
T2SK7F8D:
• 16 Gauge grey enclosure with ample knockouts for convenient access.
• Enclosure Dimensions (H x W x D): 27.25” x 21.75” x 6.5” (692.2mm x 552.5mm x 165.1mm).
T3SK75F8D and T3SK75F16D:
• 16 Gauge grey enclosure with ample knockouts for convenient access.
• Enclosure Dimensions (H x W x D): 36.12” x 30.125” x 7.06” (917.5mm x 768.1mm x 179.3mm).
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having
jurisdiction. Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws
in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper screws, level and secure.
Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install
the three fasteners. Place the enclosure’s upper keyholes over the three upper screws.
Install the three lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch (Honeywell Model 112 or equivalent)
in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the
enclosure approximately 2” from the right side (Fig. 1, pg. 2). Connect tamper switch
wiring to the Access Control Panel input or the appropriate UL Listed reporting device.
To activate alarm signal open the door of the enclosure.
4. Mount Software House boards to backplane, refer to pages 3-8.
5. Refer to the corresponding eFlow Power Supply/Charger Installation Instructions
(eFlow104NB, eFlow102NB) and Sub-Assembly Installation Instructions for the following
models: PD8UL, ACM8(CB), PDS8(CB), VR6 for further installation instructions.
- 2 - TSH Kits D
Fig. 1
T2SK7F8D: Configuration of Software House iSTAR Ultra Boards
1. Align the Software House boards on the backplane to match the boards’ mounting holes with corresponding pems.
2. Fasten standoffs (provided) to pems that match the hole pattern for Software House iSTAR Ultra GCM, iSTAR Ultra ACM, and /or
I8, R8, I8-CSI boards (Fig. 2, 2a, pg. 3).
3. Mount Software House boards to standoffs utilizing provided 5/16” pan head screws (Fig. 2a, pg. 3).
Note: Software House iSTAR Ultra ACM boards have one (1) USB port each.
Please orient the board in the appropriate position according to the Fig. 2 below.
4. Fasten backplane to Trove2 enclosure utilizing lock nuts (provided).
Standoff
Fig. 2a
Pem
Fig. 2
Rocker Switch
Altronix
eFlow104NB
Altronix
VR6 & PDS8CB
Software House
iSTAR Ultra GCM
Pan Head
Screw
Power Supply or
Sub-Assembly
Backplane
RSB2 Bracket
Software House
I8, R8 or
I8-CSI
Module
ACM8CB
Software House
iSTAR Ultra ACM
USB PORT
Altronix
TSH Kits D - 3 -