Altronix Trove Mercury kits are pre-assembled and consist of Trove3M3 enclosure/backplane with factory installed Altronix power supply/charger(s) and sub-assemblies. These kits also accommodate various combinations of Mercury boards for up to sixteen (16) doors in a
single enclosure.
Configuration Chart:
Nominal DC Output Voltage
Power Supply 1 Power Supply 2
[DC][Aux][DC][Aux]
Maximum
Supply
Current for
Main and Aux.
Outputs on Power
Supply board
and ACM8(CB)
Access Power
Altronix
Model Number
T3MK75F16
T3MK75F16D
T3MK77F16
T3MK77F16D
Output Range
(VDC)
20.17-
20.17-
20.17-
20.17-
26.4
26.4
26.4
26.4
20.28-
26.4
20.28-
26.4
20.28-
26.4
20.28-
26.4
Output Range
(VDC)
Output Range
(VDC)
9.7-
13.2
9.7-
13.2
20.17-
26.4
20.17-
26.4
10.03-
13.2
10.03-
13.2
20.28-
26.4
20.28-
26.4
Controller’s
(VDC)
outputs
Output Range
12VDC @ 9.3A
24VDC @ 9.2A
12VDC @ 9.3A
24VDC @ 9.2A
Fail-Safe/Fail-Secure or
1682.5
1682.5
24VDC @ 9.2A1692.5
24VDC @ 9.2A1692.5
Dry Form “C” Outputs
120VAC 60Hz
Input Current (A)
Current Per
ACM8(CB) Output (A)
Power Supply Board
6.3A/250V
5A/250V
6.3A/250V
5A/250V
6.3A/
250V
6.3A/
250V
Input Fuse Rating
Power Supply Board
Battery Fuse Rating
ACM8(CB) Board
15A/
10A/
32V
250V
15A/
10A/
32V
250V
15A/
10A/
32V
250V
15A/
10A/
32V
250V
Input Fuse Rating
ACM8 Board
Output Fuse Rating
ACM8CB Board
Output PTC Rating
2.5A/
250V
–
2.5A/
250V
–
2A
2A
3.5A/
–
250V
3.5A/
–
250V
PD8UL Board
Output Fuse Rating
PD8ULCB Board
–
–
2.5A
–
–
2.5A
Hardware and Accessories:
• Two (2) tamper switches (Honeywell Model 112 or equivalent).
• Cam lock.
• Battery leads.
Output Fuse Rating
Mechanical:
• 16 Gauge grey enclosure with ample knockouts for convenient access.
• Enclosure Dimensions (H x W x D): 36.12” x 30.125” x 7.06” (917.5mm x 768.1mm x 179.3mm).
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having
jurisdiction. Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws
in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper screws, level and secure.
Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install
the three fasteners. Place the enclosure’s upper keyholes over the three upper screws.
Install the three lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch (Honeywell Model 112 or equivalent)
in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the
enclosure approximately 2” from the right side (Fig. 1, pg. 2). Connect tamper switch
wiring to the Access Control Panel input or the appropriate UL Listed reporting device.
To activate alarm signal open the door of the enclosure.
4. Mount Mercury boards to backplane, refer to pg. 3, 4.
5. Refer to the corresponding eFlow Power Supply/Charger Installation Instructionsfor eFlow104NB, eFlow102NB and Sub-Assembly Installation Instructions for
PD8UL(CB) and ACM8(CB) for further installation instructions.
6. Position Mercury access controller module over corresponding standoffs and depress onto
snap on standoffs (Fig. 2-3, pg. 3-4).
7. Mount backplane to enclosure with hardware.
Fig. 1
- 2 - T3MK Kits
T3MK75F16 and T3MK75F16D: Configuration of Mercury Boards:
1. Fasten snap on standoffs onto metal pems configuration (A) (B) of backplane depending on the access controller (Fig. 2, pg. 3).
2. Position access controller module over corresponding standoffs and depress onto snap on standoffs (Fig. 2a, pg. 3).
3. Mount backplane to enclosure with hardware.
Access Controller Position Chart for the Following Models:
Mercury Access ControllerPem Mounting
EP1502, MR52, MR16IN, MR16OUT
EP2500, MUX8
Fig. 2
Rocker Switch
A
B
Fig. 2a
RSB2 Bracket
Altronix
eFlow104NB
Altronix
eFlow102NB
Altronix
ACM8(CB)
Altronix
ACM8(CB)
A
A
Pem
B
Snap on or
Metal
Standoff
Backplane
Sub-Assembly
A
A
B
A
A
Altronix PD8UL(CB)
A
T3MK Kits - 3 -
A
T3MK77F16 and T3MK77F16D: Configuration of Mercury Boards on TM3:
1. Fasten snap on standoffs onto metal pems configuration (A) (B) of backplane depending on the access controller (Fig. 3, pg. 4).
2. Position access controller module over corresponding standoffs and depress onto snap on standoffs (Fig. 3a, pg. 4).
3. Mount backplane to enclosure with hardware.
Access Controller Position Chart for the Following Models:
Mercury Access ControllerPem Mounting
EP1502, MR52, MR16IN, MR16OUT
EP2500, MUX8
Fig. 3
Rocker Switch
A
B
Fig. 3a
RSB2 Bracket
Altronix
eFlow104NB
Altronix
eFlow104NB
Altronix
ACM8(CB)
Altronix
ACM8(CB)
A
A
Pem
B
Snap on or
Metal
Standoff
Backplane
Sub-Assembly
A
A
B
A
A
Altronix PD8UL(CB)
A
Altronix PD8UL(CB)
- 4 - T3MK Kits
A
Notes:
T3MK Kits - 5 -
eFlow Power Supply/Chargers can be Controlled and Monitored while
Reporting Power/Diagnostics from Anywhere over the Network...
LINQ2 - Network Communication Module
LINQ2 provides remote IP access to real-time data from eFlow power supply/chargers to help keep
systems up and running at optimal levels. It facilitates fast and easy installation and set-up, minimizes system downtime, and eliminates unnecessary service calls, which helps reduce Total Cost
of Ownership (TCO) - as well as creating a new source of Recurring Monthly Revenue (RMR).
LINQ2
Features:
- UL Listed in the U.S. and Canada.
- Local or remote control of up to (2) two Altronix eFlow power output(s) via LAN and/or WAN.
- Monitor real time diagnostics: DC output voltage, output current, AC & battery status/service, input trigger state change,
output state change and unit temperature.
- Access control and user managment: Restrict read/write, Restrict users to specific resources
- Two (2) integral network controlled Form “C” Relays.
- Three (3) programmable input triggers: Control relays and power supplies via external hardware sources.
- Email and Windows Dashboard notifications
- Event log tracks history.
- Secure Socket Layer (SSL).
- Programmable via USB or web browser - includes operating software and 6 ft. USB cable.
LINQ2 Mounts Inside any Trove Enclosure
LINQ2 Module
Network Connection:
Installation, Programming
and Monitoring
Altronix eFlow
Power Supply
- 6 - T3MK Kits
TM3 Dimensions
34” x 28” x 0.3125” (863.6mm x 711.2mm x 7.9mm)
28.0” (711.2mm)
23.0” (584.2mm)
6.5”
(165.1mm)
34.0”
(863.6mm)
11.5”
(292.1mm)
11.5”
(292.1mm)
2.0”
(50.8mm)
T3MK Kits - 7 -
1.0” (25.4mm)
1.0” (25.4mm)
27.0” (685.8mm)
Trove3 Enclosure Dimensions (H x W x D approximate):
(50.8mm)
(222.3mm)
(222.3mm)
(219mm)
2.00”
7.12”
9.5”
9.5”
(273.1mm)
(273.1mm)
(269.8mm)
(917.5mm)
36.12” x 30.125” x 7.06” (917.5mm x 768.1mm x 179.3mm)
2.00”
(50.8mm)
10.75”
10.62”
1.25”
(31.8mm)
G
G
1.25”
(31.75mm)
1.10”
(27.9mm)
(50.8mm)
1.07”
(27.2mm)
33.63”
(854.20mm)
(222.25mm)
14.01”
(355.9mm)
(241.3mm)
30.12”
(768.1mm)
(241.3mm)
(45.21mm)
14.01”
(355.9mm)
1.78”
1.55”
(39.37mm)
2.00”
(50.8mm)
10.75”
(273.1mm)
10.62”
(269.8mm)
36.12”
10.75”
1.25”
(31.8mm)
2.00”
8.75”
8.62”
8.75”
7.06”
(179.3mm)
10.75”
(273.1mm)
1.25”
(31.8mm)
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
web site: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty | Made in U.S.A.
IITrove3M3 Kit Series I12R
- 8 - T3MK Kits
MEMBER
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.