Altronix T2KSK7F12, T2KSK3F8 Installation Guide

Access & Power Integration
T2KSK3F8
8 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove2 enclosure with TKS2 Altronix/Keri Systems backplane
- One (1) eFlow6NB - Power Supply/Charger
- One (1) ACMS8 - Dual Output Fused Access Power Controller
- One (1) VR6 - Voltage Regulator
- One (1) PDS8 - Dual Input Fused Power Distribution Module
12 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove2 enclosure with TKS2 Altronix/Keri Systems backplane
- One (1) eFlow104NB - Power Supply/Charger
- One (1) ACMS8 - Dual Output Fused Access Power Controller
- One (1) VR6 - Voltage Regulator
- One (1) PDS8 - Dual Input Fused Power Distribution Module
- One (1) ACM4 - Fused Access Power Controller
All components of these Trove kits are UL Listed sub-assemblies. Please refer to the included corresponding Sub-Assembly Installation Guides for further information.
Installation Guide
All registered trademarks are property of their respective owners. More than just power.™
Rev. TKSK_060619
Installing Company: _____________________ Service Rep. Name: __________________________________________
Address: ________________________________________________________ Phone #: _________________________
Overview:
Tamper Switch
(provided)
To Access Control Panel or UL Listed Reporting Device
Edge of
Enclosure
Enclosure
Altronix Trove Keri Systems kits are pre-assembled and consist of Trove enclosures/backplanes with factory installed Altronix power supply/chargers and sub-assemblies. Both kits accommodate a variety of Keri Systems modules for up to eight (T2KSK3F8) or twelve (T2KSK7F12) doors in a single enclosure.
Configuration Chart:
Nominal DC
Output Voltage
[DC] [Aux]
Output
Range (VDC)
Output
Range (VDC)
Fail-Safe/Fail-Secure
or Dry Form “C”
Outputs
Additional Fused
Outputs
ACMS8 Board
Input Fuse Rating
15A/
32V
15A/
32V
ACMS8 Board
Output Fuse Rating
PDS8 Board
Input Fuse Rating
3A/
10A/
32V
32V
3A/
10A/
32V
32V
PDS8 Board
Output Fuse Rating
ACM4 Board
Input Fuse Rating
3A/
32V
3A/
32V
10A/
250V
ACM4 Board
3A/
32V
Altronix Model Number
T2KSK3F8
T2KSK7F12
120VAC 60Hz
Input Current (A)
Power Supply Board
Input Fuse Rating
5A/
3.5 250V
6.3A/
4.5 250V
Maximum Supply
Current for Main and
Aux. Outputs on
Power Supply board
and ACMS8/ACM4
Access Power
Controllers’ outputs
Power Supply Board
Battery Fuse Rating
15A/
32V
15A/
32V
24VDC @ 5.7A 20.17-26.4 20.28-26.4 8 8
24VDC @ 9.4A 20.17-26.4 20.28-26.4 12 8
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top two/three keyholes in the enclosure. Install two/three upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two/three upper screws; level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s upper keyholes over the two/three upper screws. Install the three lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2” from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure.
4. Mount Keri Systems boards to backplane, refer to pages 3, 4.
5. Refer to the eFlow Power Supply/Charger Installation Guide for eFlow6NB and eFlow104NB and corresponding Sub-Assembly Installation Guides for ACMS8, PDS8, VR6 and ACM4 for further installation instructions.
Fig. 1
Output Fuse Rating
Hardware:
Nylon Spacer | 5/16” Pan Head Screw | Lock Nut
- 2 - Trove Keri Systems Kits
T2KSK3F8: Installation Instructions for Keri Systems Access Controllers
Screw
1. Fasten spacers (provided) into pem configuration (A) or (B) of backplane (Fig. 2, pg. 3).
2. Mount boards to spacers utilizing 5/16” pan head screws (provided) (Fig. 2a, pg. 3). Note: Keri Systems NXT-2D-MSCNE and NXT-4D-MSCNE boards have one (1) RJ45 jack each. Please make sure that they are mounted correctly, as shown in Fig. 2 below.
3. Mount backplane to enclosure with hardware. If use of NXTWI or NXTRM3 expansion boards is desired, there is no need to remove NXT-2D-MSCNE, NXT-4D-MSCNE or NXT-4X4NE from the TKS2.
Keri Systems Access Controller Position Chart for the Following Models:
Keri Systems Board Pem Mounting
NXT-2D-MSCNE, NXT-4D-MSCNE A
NXT-4X4NE B
Fig. 2
OFF - 24V
ON
ON - 12V
Altronix
eFlow6NB
L G N
+
PWR1
+
PWR2
+ PWR1
-­+ PWR2
--
COM -
NC C NO NC
AC FAIL BAT FAIL
Altronix ACMS8
DM1 +
OFF
IN1 Fuse
IN1
10
IN2
+ INP1
IN2 Fuse
--
10
+ INP2
--
Common (--- )
DM2 +
Altronix PDS8
<
<
<
<
1 off 2
1 off 2
1 off 2
1 off 2
33333333
Out1
Out2
Out3
>
P
N
1 2 3 4 5 6 7 8
Out4
>
>
>
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8
Common Power Outputs (NEG)
Altronix VR6 mounted under PDS8
B
- BAT +- DC +
AC DCAC1
EOLNOGND
TRIGGER
C NO
SUPERVISED RESET
PWR1
+AUX-
+
+
PWR2
COM -
RJ45 Jack
A
B
RJ45 Jack
A
DM1 +
<
<
<
<
1 off 2
1 off 2
1 off 2
1 off 2
Out5
Out6
Out7
Out8
>
>
>
>
Common (--- )
DM2 +
B
RJ45 Jack
A
RJ45 Jack
A
Fig. 2a
Pem
Spacer
Pan Head
Keri Systems Board
Trove Keri Systems Kits - 3 -
Backplane
Loading...
+ 5 hidden pages