Altronix T2KHK3F12 Installation Guide

Access & Power Integration
T2KHK3F12
12 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove2 enclosure with TKH2 Altronix/Kantech backplane
- One (1) eFlow6NB - Power Supply/Charger
- One (1) T1618300K - Transformer
- One (1) ACM4 - Fused Access Power Controller
- One (1) ACM8 - Fused Access Power Controller
All components of this Trove kit are UL Listed sub-assemblies. Please refer to the included corresponding Sub-Assembly Installation Guides for further information.
Installation Guide
All registered trademarks are property of their respective owners. More than just power.™
Installing Company: _____________________ Service Rep. Name: __________________________________________
Address: ________________________________________________________ Phone #: _________________________
Overview:
Tamper Switch
(provided)
To Access Control Panel or UL Listed Reporting Device
Edge of
Enclosure
Enclosure
Altronix T2KHK3F12 Trove Kantech kit is pre-assembled and consists of Trove2KH2 enclosure/backplane with factory installed Altronix power supply/charger and sub-assemblies. T2KHK3F12 kit also accommodates various combinations of Kantech boards for up to twelve (12) doors in a single enclosure.
TKH2 accommodates a combination of the following Kantech boards:
Up to four (4) KT-MOD-INP16 or KT-MOD-OUTP16.
Up to four (4) KT300.
Up to three (3) KT400.
Configuration Chart:
Nominal DC Output
Voltage
[DC] [Aux]
Output
Range (VDC)
Output
Range (VDC)
Fail-Safe/Fail-Secure
or Dry Form “C”
Outputs
ACM4 Board
Input Fuse Rating
ACM4 Board
10A/
250V
3A/
32V
Output Fuse Rating
ACM8 Board
Input Fuse Rating
10A/
250V
2.5A/ 250V
Altronix Model Number
T2KHK3F12
Power Supply Board
Input Fuse Rating
Power Supply Board
Battery Fuse Rating
120VAC 60Hz
5A/
10A/
250V
3.5 24VDC @ 5.4A 20.17-26.4 20.28-26.4 12
32V
Maximum Supply
Current for Main and
Aux. Outputs on
Power Supply board
and ACM4/ACM8
Access Power
Input Current (A)
Controllers’outputs
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper screws, level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s upper keyholes over the three upper screws. Install the three lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2” from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure.
4. Mount Kantech boards to TKH2 backplane, refer to page 3.
5. Refer to the eFlow Power Supply/Charger Installation Guide for eFlow6NB and corresponding Sub-Assembly Installation Guides for the following models: ACM8, ACM4 and T1618300K for further installation instructions.
ACM8 Board
Output Fuse Rating
- 2 - T2KHK3F12
Fig. 1
1 2 3 4
ON
1 2 3 4
ON
Configuration of Kantech Boards:
1. Align Kantech boards on the backplane to match the boards’ mounting holes with corresponding holes in backplane. a. Position spacer over appropriate hole on the rear of backplane and depress it until it locks in place (Fig. 2a, pg. 3, Step 1a). b. Depress down on board to secure it to the spacer (Fig. 2a, pg. 3, Step 1b).
2. Fasten backplane to Trove2 enclosure utilizing pan head screws (provided).
Kantech Access Controller Position Chart for the Following Models:
Kantech Board Pem Mounting
KT-400 Door Controller A
KT-300 Door Controller B
KT-MOD-INP16 or KT-MOD-OUTP16 Expansion Boards C
Fig. 2
L G N
TRG
Altronix
INPUT
TRIGGER
IN GND
IN GND
IN GND
IN GND
ACM4
4
3
2
1
Altronix
eFlow6NB
NC C NO NC
AC FAIL BAT FAIL
Altronix
T1618300K
FACP
INTERFACE
NO C NC
+INP- T +RET-
CONTROL
-- +
LED1 LED2 LED3 LED4
C NO
MAIN
NC C NO COM NC C NO COM NC C NO COM NC C NO COM
Fig. 2a
Step 1a
OFF - 24V
ON
ON - 12V
Kantech
B
A
- BAT +- DC +
AC DCAC1
EOL NO GND
TRIGGER
+AUX-
SUPERVISED RESET
C
Spacer
Back of TKH2
B
A
POWER
-- +
OUTPUT 4
C
B
C
OUTPUT 2 OUTPUT 3
OUTPUT 1
A
Step 1b
Kantech
Board
FACP
TRIGGER INPUT
IN GND IN GND IN GND IN GNDIN GND IN GND IN GND IN GND
5 6 7 8
1 2 3 4
F1 F2 F3 F4 F5 F6 F7 F8
NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM
OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8
TRG
+INP- T + RET-
ON
ON
FACP INTERFACE
1 2 3 4
1 2 3 4
NO C NC
Altronix
ACM8
MAIN
10A 250V
- + - + Power Control
B
C
T2KHK3F12 - 3 -
6.25” (158.8mm)
1.25” (31.8mm)
Enclosure Dimensions (H x W x D):
27.25” x 21.75” x 6.5” (692.2mm x 552.5mm x 165.1mm)
21.50” (546.1mm)
2.00” (50.8mm) 2.00” (50.8mm)
1.25”
(31.8mm)
5.25” (133.35mm)
0.5625” (14.3mm)
3.5”(88.9mm) 3.5”(88.9mm)
(45mm)
2.415” (61.3mm)
1.5”
(38.1mm)
19.80” (502.9mm)
1.77”
5.25” (133.35mm)
0.685” (17.4mm)
Knockouts
1.125” (28.3mm)
0.885” (22.5mm)
6.25” (158.8mm)
2.00” (50.8mm)
6.75” (171.5mm)8.25” (209.5mm)
1.00” (25.4mm)
2.00” (50.8mm)
27” (685.8mm)
0.85” (21.6mm)
5.25” (133.4mm) 5.25” (133.4mm)7.00” (177.8mm)
8.00” (203.2mm)
2.00” (50.8mm)
1.25” (31.8mm)
1.25” (31.8mm)
2.00” (50.8mm)
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 web site: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty | Made in U.S.A. IIT2KHK3F12 K04S
- 4 - T2KHK3F12
MEMBER
Loading...