T1RV3F4
Trove / HID VertX® Kit
Access & Power Integration Solution
Description
Altronix T1RV3F4 Trove™ Rack kit is pre-assembled and consists of
Trove1V1R enclosure/backplane with the following factory installed
Altronix components:
- One (1) eFlow6NB - power supply/charger set at 24VDC;
- One (1) VR6 - Voltage Regulator;
- One (1) PDS8 - Fused Dual Output Power Distribution Module;
- One (1) ACM4 - Fused Access Power Controller.
®
This kit also accommodates various combinations of HID VertX
for up to four (4) doors in a single enclosure.
Key Features
boards
T1RV3F4
- Output Power:
- Four (4) 24VDC fused lock power outputs rated at 6A total max.
- Fire Alarm Disconnect is individually selectable by output.
- Eight (8) individully selectable 12VDC or 24VDC fused power
outputs rated at 6A total max. for readers, REXs, controllers, etc.
- Accommodates the following HID VertX
V100, V200, V300, V1000, V2000.
- Power status LED on front panel.
- Simplified board layout and wire management.
*Altronix Power Supply/Charger and Sub-Assemblies only
®
controllers:
- Convenient knockout configuration:
- Six (6) 1.25” diameter knockouts located on the back
of enclosure.
- 6’ IEC320 3-wire power cord.
- 2U drawer on extendable rails.
- Included Z Bracket facilitates ease of wiring.
- Black powder coated steel enclosure.
- Includes cam lock, tamper switch and mounting hardware.
- CE European Conformity.
- Lifetime Warranty* / Made in the U.S.A.
Optional Accessories
- RE2:
Rack Mount Battery Enclosure accommodates up to four (4) 12VDC/7AH batteries.
- WM5, WM25, WM100:
Magnetic Cable Tie Mounts (5, 25, 100 counts).
Rev. T1RV3F4 - 07282020

T1RV3F4
®
Trove / HID VertX
Kit
Access & Power Integration Solution
Specifications
Power Supply/Charger (eFlow6NB):
Input
Voltage 120VAC, 60Hz, 3.5A max.
Main Fuse 5A / 250V.
Outputs
Voltage Factory set at 24VDC.
Current 6A continuous.
Maximum Supply Current for Main and Aux. Outputs on
eFlow6NB Power Supply board, PDS8 Power Distribution Module’s
and ACM4 Access Power Controller’s outputs is 5.6A.
Auxiliary Class 2 power-limited @ 1A (unswitched).
Other Overvoltage protection.
Filtered and regulated.
Battery Backup
Type Sealed lead acid or gel type.
Fuse Rating 10A @ 32VDC.
Failover Upon AC loss, instantaneous.
Fire Alarm Disconnect
Supervised Latching or non-latching.
EOL 10K Resistor.
Supervision
AC Failure Form “C” contacts.
Battery Form “C” contacts.
Low DC Power Shutdown
Shuts down DC output terminals if battery voltage drops below
70-75% for 24V units. Prevents deep battery discharge.
Indicators (LED)
Input 120VAC is present.
DC Output Powered.
Battery Discharged or not connected.
Power Distribution Module (PDS8):
Input
Voltage 24VDC from eFlow6NB and 12VDC from VR6.
Main Fuse 10A / 250V.
Outputs
Voltage 12 or 24VDC individually selectable.
Output Fuses 3A / 32VDC.
Indicators (LED)
DC Output Eight (8) individual output LEDs.
Green: 12VDC
Red: 24VDC.
Access Power Controller (ACM4):
Input
Voltage 24VDC from eFlow6NB.
Main Fuse 10A / 250V.
Outputs
Voltage 24VDC.
Four (4) independently controlled 2.5A outputs:
a) Four (4) Fail-Safe and/or Fail-Secure power outputs.
b) Four (4) dry form “C” 5A rated relay outputs.
c) Any combination of the above.
Four (4) auxiliary power outputs (unswitched).
Output Fuses 3A / 32VDC.
Indicators (LED)
Red LEDs Outputs are triggered (relays energized).
Green LED FACP disconnect is triggered.
Voltage Regulator (VR6):
Input
Voltage 24VDC from eFlow6NB.
Output
Voltage 12VDC.
Current 6A continuous.
Other Surge suppression.
Indicators (LED)
Input 24VDC is present.
Output Powered.
T1RV3F4 Kit:
Agency Listings
CE European Conformity.
Physical and Environmental:
Dimensions (H x W x D):
Modular 2U standard EIA 19” rack mount chassis.
3.25” x 19.0” x 26.5” (82.6mm x 482.6mm x 673.1mm).
Weights:
Product 20 lbs. (9.07 kg).
Shipping 25 lbs. (11.34 kg).
Temperature
Operating 0ºC to 49ºC (32ºF to 120ºF).
Storage -20ºC to 70ºC (-4ºF to 158ºF).
Relative Humidity 85% +/-5%.
BTU/Hr.: 115 BTU/Hr.

T1RV3F4
®
Trove / HID VertX
Kit
Access & Power Integration Solution
Access Controller Position Chart for the Following Models:
Altronix / Mercury Pem Mounting
V100, V200, V300, V1000, V2000 A
Genetec Synergis Cloud Link B
A
L G N
B
eFlow6NB
NC C NO NC C NO
AC FAIL BAT FAIL
eFlow6NB
A
A
AC DCAC1
1 min enable
2 hr disable
TRIGGER EOL
SUPERVISED
NO GND
RESET
+ AUX -
--- BAT + --- DC +
TRIGGER
IN GND1IN GND2IN GND3IN GND
LED1 LED2 LED3 LED4
NC C NO COM NC C NO COM NC C NO COM NC C NO COM
OUTPUT 1
PWR1+
Fuse1
IN2 Fuse
+ INP1 - + INP2 -
INPUT
4
OUTPUT 2 OUTPUT 3
VR6 & PDS8
IN1 Fuse
Fuse2 Fuse3 Fuse4 Fuse5 Fuse6 Fuse7 Fuse8
ACM4
OUTPUT 4
PDS8
Dual Voltage
Power Distribution
Module
OPEN - 24V
CLOSED - 12V
TRG
INTERFACE
+INP- T +RET-
FACP
NO C NC
ACM4
ACCESS POWER
CONTROLLER
PWR1+
-- +
CONTROL
POWER
-- +
MAIN
P
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8
COM(-)
N
PWR2+
1 2 3 4 5 6 7 8
Common Power Outputs (NEG)
P
N
COM(-)
PWR2+

T1RV3F4
®
Trove / HID VertX
Kit
Access & Power Integration Solution
26.5”
673.1mm
2.4”
61mm
4.57”
116.1mm
1” (25.4mm)
11.175” (283.8mm)
0.55” (14mm)
R 1.27” (32.3mm)
0.1”
2.5mm
3.62”
92mm
1.5”
38.1mm
3.25”
82.3mm
19” (482.6mm)
Altronix Corporation | 140 58th St | Brooklyn, NY 11220 USA
phone: +1 718.567.8181 | fax: +1 718.567.9056 | email: info@altronix.com | www.altronix.com