Overview:
Altronix T1RSH3F8 rack kit is pre-assembled and consist of Trove1SH1R enclosure/backplane with factory installed Altronix power sup­ply/charger and sub-assemblies. This kit also accommodates various combinations of Software House boards for up to eight (8) doors in a single enclosure.
Configuration Chart:
Nominal DC
Output Voltage
[DC] [Aux]
Output
Range (VDC)
20.19-26.4 20.19-26.4 24VDC @ 5.8A 8 2.5
Output
Range (VDC)
Maximum Supply
Current for Main and
Aux. Outputs on Power
Supply board and
ACMS8 Access Power
Controller’s outputs
Fail-Safe/
Fail-Secure
or
Dry Form
“C”
Outputs
Current
Per
ACMS8
Output
(A)
ACMS8
Board
Input
Fuse
Rating
15A/
32V
ACMS8
Board
Output
Fuse
Rating
3A/
32V
Altronix Model Number
T1RSH3F8
120VAC
60Hz
Input
Current
(A)
3.5
Power
Supply
Board
Input
Fuse
Rating
5A/
250V
Power
Supply
Board
Battery
Fuse
Rating
10A/
32V
Hardware and Accessories:
Spacer | 5/16” Pan Head Screw | Lock Nut
Specifications:
Agency Listings:
• CE European Conformity.
Mechanical:
• Black enclosure with ample knockouts for convenient access.
• Includes: tamper switch, cam lock and mounting hardware.
• Modular 2U standard EIA 19” drawer with extendable slides up to 48”.
• Dimensions (H x W x D): 3.25” x 19.0” x 26.5” (82.6mm x 482.6mm x 673.1mm).
Included Accessories:
• One (1) tamper switch (Altronix Model TS112 or equivalent).
• Cam lock.
Available Accessories (not included):
RE2: Rack Mount Battery Enclosure accommodates up to four (4) 12VDC/7AH batteries.
WM5, WM25, WM100: Magnetic Cable Tie Mounts (5, 25, 100 counts).
- 2 - T1RSH3F8
Assembling and Attaching Z Bracket Wire Management Accessory (included):
Altronix Trove Rack enclosures include Z Bracket, a convenient and reliable wire management accessory.
1. Carefully unpack Z Bracket. Do not discard hardware (included) (Fig. 1, pg. 3).
2. Attach arms to each other using bolts and lock nuts (Fig. 1a, pg. 3).
3. Attach the hinge brackets to the ends of arms using bolts and nuts positioning them as shown on Fig. 1b, pg. 3.
4. Make sure that all nuts are tightened.
Hardware (included):
Ten (10) bolts and eight (8) lock nuts
Fig. 1a
5. Attach the hinge bracket on the longer side of Z Bracket to the adjustable rail using bolts and lock nuts (included) (Fig. 2, 2a, pg. 3).
6. Attach the hinge bracket on the shorter side of Z Bracket to the rear of the rack enclosure using bolts (included).
Fig. 2
Fig. 1
Two (2)
Fig. 1b
Fig. 2a
T1RSH3F8 - 3 -
Installation Instructions for T1RSH3F8:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only.
1. Remove backplane from enclosure prior to installing into rack cabinet (do not discard hardware).
2. In order to mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) turn the enclosure upside down. Punch out the knockout in designated location, on the back of the unit, from outside of the drawer (Fig. 3, pg. 3). Insert the tamper switch into the knockout from outside of the drawer with the button facing outwards and spaded connectors inside the drawer. Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the rack drawer.
3. Slide the Trove rack enclosure into an open 2U location in the rack cabinet.
4. Utilizing proper fasteners attach front ears to the rack rails.
5. Attach the rear of the adjustable slides to the rear rails of the rack cabinet with the proper fasteners.
6. Make sure that all internal cofigurations (wiring, voltage selection, switch settings, etc.) are complete before mounting backplane back into enclosure.
7. After all components are mounted on the backplane, attach it to the enclosure using included hardware.
8. Mount Software House modules to TSH1R backplane, refer to page 5.
9. Refer to the eFlow Power Supply/Charger Installation Guide for eFlow6NB and corresponding sub-assembly Installation Guides for the following models: ACMS8(CB), VR6 for further instructions.
Fig. 3
Back of the drawer,
viewed from outside.
Tamper Switch mounting location
- 4 - T1RSH3F8
T1RSH3F8: Configuration of Software House Boards:
1. Fasten spacers onto metal pems configuration (A), (B), or (C) of backplane depending on the access controller (Fig. 4, pg. 5).
2. Position access controller module over corresponding spacers and fasten screws into spacers (Fig. 4a, pg. 5). Note: Software House iSTAR Ultra ACM and iSTAR ACM SE/ACM PRO boards have one (1) USB port each. Please orient boards in the appropriate position according to the Fig. 4 below.
3. Mount backplane to enclosure with hardware.
Access Controller Position Chart for the Following Models:
Software House Access Controller Pem Mounting
iSTAR Ultra ACM
iSTAR ACM SE/ACM PRO
I8, R8 or I8-CSI Module
Fig. 4
A
B
C
C
C
To IEC
connector
L G N
NC C NO
AC FAIL
NC C NO
BAT FAIL
AC
DCAC1
enable
2 hr.
disable
TRIGGER EOL
SUPERVISED
NO GND
RESET
+ AUX ---
Fig. 4a
Pan Head Screw
Power Supply or Sub-Assembly
eFlow6NB
Spacer
Pem
Backplane
OFF - 24V ON - 12V
1 min
--- BAT + --- DC +
COM -
ON
+
PWR2
+
PWR1
USB PORT
B
ACMS8
VR6 is
mounted
under
ACMS8
C
USB PORT
+
+
PWR2
PWR1
A
--
--
+ PWR2
+ PWR1
T1RSH3F8 - 5 -
COM -
Notes:
- 6 - T1RSH3F8
Notes:
T1RSH3F8 - 7 -
Trove1R Enclosure Dimensions (H x W x D):
3.25” x 19.0” x 26.5” (82.6mm x 482.6mm x 673.1mm). Shown with Z Bracket attached.
26.5”
673.1mm
2.4”
61mm
4.57”
116.1mm
1” (25.4mm)
11.175” (283.8mm)
0.55” (14mm)
R 1.27” (32.3mm)
0.1”
2.5mm
3.62”
92mm
1.5”
38.1mm
19” (482.6mm)
3.25”
82.3mm
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 web site: www.altronix.com | e-mail: info@altronix.com | Made in U.S.A. IIT1RSH3F8 H24T
- 8 - T1RSH3F8
MEMBER
Loading...