Access & Power Integration
T1PDK7F24
24 Door Kit
Fully assembled kit includes:
- Trove1 enclosure with TPD1 Altronix/PDK backplane
- One (1) eFlow104NB - Power Supply/Charger
All components of this Trove kit are UL Listed sub-assemblies.
Please refer to the included corresponding Sub-Assembly Installation Guides for further information.
Installation Guide
All registered trademarks are property of their respective owners. More than just power.™
Rev. 040419
Installing Company: _____________________ Service Rep. Name: __________________________________________
Address: ________________________________________________________ Phone #: _________________________

Overview:
Tamper Switch
(provided)
To Access Control Panel or
UL Listed Reporting Device
Edge of
Enclosure
Enclosure
Altronix T1PDK7F24 Trove PDK kit is pre-assembled and consists of Trove1PD1 enclosure/backplane with factory
installed Altronix power supply/charger. T1PDK7F24 kit also accommodates up to three (3) PDK 8DEE modules for up
to twenty-four (24) doors in a single enclosure.
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and
authorities having jurisdiction. Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners
and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper
screws, level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and
install the three fasteners. Place the enclosure’s upper keyholes over the three upper screws. Install the three lower
screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent)
in desired location, opposite hinge. Slide the tamper switch bracket onto the edge
of the enclosure, approximately 2” from the right side (Fig. 1, pg. 2).
Connect tamper switch wiring to the Access Control Panel input or the
appropriate UL Listed reporting device. To activate alarm signal
open the door of the enclosure.
4. Mount PDK 8DEE modules to TPD1 backplane, refer to page 3.
5. Refer to the eFlow Power Supply/Charger Installation Guide for
further installation instructions.
Fig. 1
Hardware:
Nylon Spacer | 5/16” Pan Head Screw | Lock Nut
- 2 - T1PDK7F

Configuration of PDK 8DEE Modules:
1. Fasten spacers (provided) to pems that match the hole pattern for PDK 8DEE modules (Fig. 2, pg. 3).
2. Mount boards to spacers utilizing 5/16” pan head screws (provided) (Fig. 2, 2a, pg. 3).
Note: PDK 8DEE modules have one (1) RJ45 jack each.
Please make sure that they are mounted correctly, as shown in Fig. 2 below.
4. Fasten TPD1 backplane to Trove1 enclosure utilizing hardware (provided).
Fig. 2
L G N
RJ45 Jack
Altronix
eFlow104NB
PDK
8DEE
RJ45 Jack
PDK
8DEE
– DC +– BAT +
RJ45 Jack
PDK
8DEE
Fig. 2a
Pem
Spacer
Pan Head
Screw
T1PDK7F - 3 -
PDK
8DEE module
Backplane

Trove1 Enclosure Dimensions (H x W x D approximate):
18” x 14.5” x 4.625” (457mm x 368mm x 118mm)
14.5” (321.3mm)
7.25” (184.2mm)
1.5” (38.1mm)
8.5” (215.9mm)6.5” (165.1mm)
1.45” (36.8mm)
1.95” (49.5mm)
4.5” (114.3mm)
1.25” (31.8mm) 1.25” (31.8mm)
13.0” (330.2mm)
0.6” (15.2mm)
0.57” (14.5mm)
18.0” (457.2mm)
1.5” (38.1mm)
8.5” (215.9mm)6.5” (165.1mm)
0.6” (15.2mm)
1.1” (27.9mm)
4.5” (114.3mm) 4.5” (114.3mm)
2.75”
(69.9mm)
1.115” (28.3mm)
1.36” (34.5mm)
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
web site: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty | Made in U.S.A.
IIT1PDK7F D30T
- 4 - T1PDK7F
1.25” (31.8mm)
MEMBER