Altronix T1MK1F4SD, T1MK1F4S Installation Guide

Access & Power Integration
T1MK1F4
4 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove1 enclosure with TM1 Altronix/Mercury backplane
- (1) eFlow4NB - Power Supply/Charger
- (1) VR6 - Voltage Regulator
- (1) ACM4 - Fused Access Power Controller
T1MK1F4S
4 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove1 enclosure with TM1 Altronix/Mercury backplane
- (1) eFlow4NB - Power Supply/Charger
- (1) VR6 - Voltage Regulator
- (1) ACM4 - Fused Access Power Controller
All components of these Trove kits are UL Listed sub-assemblies. Please refer to the included corresponding Sub-Assembly Installation Guides for further information.
T1MK1F4D
4 Door Kit with PTC Outputs
Fully assembled kit includes:
- Trove1 enclosure with TM1 Altronix/Mercury backplane
- (1) eFlow4NB - Power Supply/Charger
- (1) VR6 - Voltage Regulator
- (1) ACM4CB - PTC Access Power Controller
T1MK1F4SD
4 Door Kit with PTC Outputs
Fully assembled kit includes:
- Trove1 enclosure with TM1 Altronix/Mercury backplane
- (1) eFlow4NB - Power Supply/Charger
- (1) VR6 - Voltage Regulator
- (1) ACM4CB - PTC Access Power Controller
- (1) PDS8CB - Dual Input Power Distribution Module
Installation Guide
All registered trademarks are property of their respective owners. More than just power.™
Rev. T1MK022719
Installing Company: _____________________ Service Rep. Name: __________________________________________
Address: ________________________________________________________ Phone #: _________________________
Overview:
Tamper Switch
(provided)
To Access Control Panel or UL Listed Reporting Device
Edge of
Enclosure
Enclosure
Altronix Trove Mercury kits are pre-assembled and consist of Trove1M1 enclosure/backplane with factory installed Altronix power supply/charger and sub-assemblies. These kits also accommodate various combinations of Mercury boards for up to four (4) doors in a single enclosure.
Configuration Chart:
Maximum
Supply Current
for Main and Aux. Outputs
on Power
Supply board
and ACM4/
ACM4CB
Access Power
Controller’s
outputs (A)
Range (V)
24VDC @ 3.6A 4 2.5
24VDC @ 3.6A 4 2.0
24VDC @ 3.6A 4 2.5
24VDC @ 3.6A 4 2.0
Fail-Safe/Fail-Secure or
Dry Form “C” Outputs
Fail-Safe/Fail-Secure
Outputs (auto-resettable)
Current Per
ACM4 Output (A)
Current Per
ACM4CB Output (A)
ACM4/ACM4CB Board
Input Fuse Rating
ACM4 Board
Output Fuse Rating
10A/
10A/
10A/
10A/
3A/
250V
2.0A
3A/
250V
2.0A
250V
250V
250V
250V
ACM4CB Board
Output PTC Rating
PDS8/PDS8CB Board
Input Fuse Rating
PDS8 Board
Output Fuse Rating
10A/
10A/
3A/
250V
2.0A
250V
250V
PDS8CB Board
Output PTC Rating
Altronix Model Number
T1MK1F4
T1MK1F4D
T1MK1F4S
T1MK1F4SD
120VAC 60Hz
Input Current (A)
Power Supply Board
Input Fuse Rating
5A/
3.5 250V
5A/
3.5 250V
5A/
3.5 250V
5A/
3.5 250V
Nominal DC
Output Voltage
[DC] [Aux]
Power Supply Board
Battery Fuse Rating
24VDC Output
Range (V)
7.5A/
20.28-
32V
7.5A/ 32V
7.5A/ 32V
7.5A/ 32V
26.4
20.28-
26.4
20.28-
26.4
20.28-
26.4
24VDC Output
20.28-
26.4
20.28-
26.4
20.28-
26.4
20.28-
26.4
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI and with all local codes and authorities having jurisdiction. Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top two (2) keyholes in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two upper screws; level and secure. Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the two fasteners. Place the enclosure’s upper keyholes over the three upper screws. Install the two lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch (Altronix Model T112 or equivalent) in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2” from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure.
4. Position Mercury access controller modules over corresponding spacers and depress onto snap on spacers, Fig. 2, pg. 3.
5. Refer to the eFlow Power Supply/Charger Installation Guide for eFlow4NB, and corresponding Sub-Assembly Installation Guide for ACM4(CB), PDS8(CB) and VR6 for further installation instructions.
6. Mount backplane to enclosure with hardware.
Fig. 1
- 2 - T1MK Kits
T1MK1F4 and T1MK1F4D: Configuration of Mercury Boards:
1. Fasten snap on spacers onto metal pems configuration (A), (B), (C) or (D) of backplane depending on the access controller (Fig. 2, pg. 3).
2. Position access controller module over corresponding spacers and depress onto snap on spacers (Fig. 2a, pg. 3).
3. Mount backplane to enclosure with hardware.
Access Controller Position Chart for the Following Models:
Mercury Access Controller Pem Mounting
EP1502, LP1502, MR52, MR16IN, MR16OUT EP1501, LP1501, MR51e, MR62e MR50 EP2500, LP2500, MUX8
Fig. 2
+ IN - +OUT-
ON-5V OFF-12V
Altronix
VR6
A B C D
Fig. 2a
Pem
Snap On Spacer
Backplane
A
Altronix
eFlow4NB
– DC +– BAT +
B
A
D D
C
TRIGGER
IN GND1IN GND2IN GND3IN GND
INPUT
4
Altronix ACM4(CB)
LED1 LED2 LED3 LED4
NC C NO COM NC C NO COM NC C NO COM NC C NO COM
OUTPUT 1
OUTPUT 2 OUTPUT 3
OUTPUT 4
B
C
Mercury Board
TRG
INTERFACE
+INP- T +RET-
FACP
NO C NC
ACM4
ACCESS POWER
CONTROLLER
-- + CONTROL
POWER
-- +
MAIN
T1MK Kits - 3 -
T1MK1F4S and T1MK1F4SD: Configuration of Mercury Boards:
1. Fasten snap on spacers onto metal pems configuration (A), (B), (C) or (D) of backplane depending on the access controller (Fig. 3, pg. 4).
2. Position access controller module over corresponding spacers and depress onto snap on spacers (Fig. 3a, pg. 4).
3. Mount backplane to enclosure with hardware.
Access Controller Position Chart for the Following Models:
Mercury Access Controller Pem Mounting
EP1502, LP1502, MR52, MR16IN, MR16OUT EP1501, LP1501, MR51e, MR62e MR50 EP2500, LP2500, MUX8
Fig. 3
Altronix
eFlow4NB
– DC +– BAT +
DM1 +
OFF
IN1 Fuse IN1 IN2
+ INP1
IN2 Fuse
--
+ INP2
--
Altronix PDS8(CB)
<
<
1 off 2
1 off 2
Out1
Out2
>
>
P
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8
Common (--- )
N
DM2 +
1 2 3 4 5 6 7 8
Common Power Outputs (NEG)
TRIGGER
IN GND1IN GND2IN GND3IN GND
INPUT
4
< 1 off 2
Out3
>
Altronix ACM4(CB)
LED1 LED2 LED3 LED4
NC C NO COM NC C NO COM NC C NO COM NC C NO COM
OUTPUT 1
OUTPUT 2 OUTPUT 3
< 1 off 2
>
Out4
OUTPUT 4
DM1 +
<
<
<
1 off 2
Out6
>
TRG
ACM4
ACCESS POWER
CONTROLLER
1 off 2
Out7
>
Common (--- )
DM2 +
< 1 off 2
Out8
>
INTERFACE
+INP- T +RET-
FACP
NO C NC
-- + CONTROL
POWER
-- +
1 off 2
Out5
>
MAIN
A B C D
Fig. 3a
Pem
Snap On Spacer
Backplane
Mercury Board
A
B
A
B
D D
C
- 4 - T1MK Kits
C
eFlow Power Supply/Chargers can be Controlled and Monitored while
Reporting Power/Diagnostics from Anywhere over the Network...
LINQ2 - Network Communication Module
LINQ2 provides remote IP access to real-time data from eFlow power supply/chargers to help keep systems up and running at optimal levels. It facilitates fast and easy installation and set-up, mini­mizes system downtime, and eliminates unnecessary service calls, which helps reduce Total Cost of Ownership (TCO) - as well as creating a new source of Recurring Monthly Revenue (RMR).
LINQ2
Features:
- UL Listed in the U.S. and Canada.
- Local or remote control of up to (2) two Altronix eFlow power output(s) via LAN and/or WAN.
- Monitor real time diagnostics: DC output voltage, output current, AC & battery status/service, input trigger state change, output state change and unit temperature.
- Access control and user managment: Restrict read/write, Restrict users to specific resources
- Two (2) integral network controlled Form “C” Relays.
- Three (3) programmable input triggers: Control relays and power supplies via external hardware sources.
- Email and Windows Dashboard notifications
- Event log tracks history.
- Secure Socket Layer (SSL).
- Programmable via USB or web browser - includes operating software and 6 ft. USB cable.
LINQ2 Mounts Inside any Trove Enclosure
LINQ2 Module
Network Connection:
Installation, Programming and Monitoring
Altronix eFlow
Power Supply
- 5 - T1MK Kits
Notes:
- 6 - T1MK Kits
Notes:
- 7 - T1MK Kits
Trove1 Enclosure Dimensions (H x W x D approximate):
18” x 14.5” x 4.625” (457mm x 368mm x 118mm)
14.5” (321.3mm)
7.25” (184.2mm)
1.5” (38.1mm)
8.5” (215.9mm)6.5” (165.1mm)
1.45” (36.8mm)
1.95” (49.5mm)
4.5” (114.3mm)
1.25” (31.8mm) 1.25” (31.8mm)
13.0” (330.2mm)
0.6” (15.2mm)
0.57” (14.5mm)
18.0” (457.2mm)
1.5” (38.1mm)
8.5” (215.9mm)6.5” (165.1mm)
0.6” (15.2mm)
1.1” (27.9mm)
4.5” (114.3mm) 4.5” (114.3mm)
2.75”
(69.9mm)
1.115” (28.3mm)
1.36” (34.5mm)
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 web site: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty | Made in U.S.A. IITrove1M1 Kit Series A15T
- 8 - T1MK Kits
1.25” (31.8mm)
MEMBER
Loading...