![](/html/67/672c/672cf95dfab61806ec54f542f295de53e4f38556a58010cc1db5a91bbee76100/bg1.png)
StrikeIt4
Low Current Locking Device Power Controller
Description
Altronix StrikeIt4 will operate up to two (2) low current lock hardware devices simultaneously. It
is designed to operate motorized electric latch retraction exit devices, electric strikes, mag-locks,
electric mortise and cylindrical locksets, etc. Each lock output has an adjustable re-lock delay timer.
It will control a pair of doors simultaneously, or independently control two single door leafs. StrikeIt4
has integrated output relays which trigger automatic door operators and control ADA activation push
plates/accessories. In addition, one (1) 12VDC and one (1) 24VDC unswitched auxiliary voltage
outputs are provided for powering ancillary devices. A configurable FACP interface will either remove
or apply power from the lock outputs when activated. LED status indicators are provided to monitor
input status, battery condition, AC power loss, and FACP status. Intelligent logic provides protection
against accidental shorting of lock outputs.
Specifications
Input
Voltage 115VAC, 60Hz, 2.5A or
230VAC, 50Hz, 1.5A.
Two (2) Normally Open (N.O.) trigger inputs.
FACP Normally Closed (N.C.) input.
Two normally open ADA inputs for special mode of
interfacing with automatic door operators.
Fusing Input fuse rating: 3A.
Outputs
Power options:
- Two (2) 19.8VDC-26.4VDC rated individually controlled lock outputs
configurable for fail-secure or fail-safe electronic locking hardware for
applications with battery back-up. 24VDC-26.4VDC rated for applications
without battery back-up (US applications only).
Current rating 2A combined.
- One (1) 19.8VDC-26.4VDC @ 0.8A rated filtered regulated auxiliary output
for applications with battery back-up, 24VDC-26.4VDC @ 0.8A rated for
applications in US not requiring battery back-up.
Not affected by FACP trigger.
- One (1) 12VDC filtered regulated auxiliary output rated 0.5A.
Not affected by FACP trigger.
- Two (2) follower Normally Open relay outputs for controlling
ADA actuators/accessories rated 28VDC @ 0.5A.
- Two momentary door operator activation relay outputs.
- Trouble relay output indicating low AC voltage trouble and battery trouble.
Back-up Battery
Type Sealed lead acid or gel type.
Failover Upon AC loss, instantaneous.
When 7AH batteries are used, battery capacity
for emergency stand-by is 30 minutes.
Fire Alarm Disconnect
Normally Closed FACP trigger input.
Programmable Fire Alarm Disconnect options:
- Removes power to outputs and disables delayed follower relays.
- Connects power to lock outputs and enables
delayed follower relays.
Indicators (LED)
AC Power (Green) Input voltage is present.
Trigger Output (Red) Panic device status/trouble.
FAI (Green) FACP disconnect.
Battery (Red) Low battery.
Agency Listings
UL
UL 294 Access Control Unit Power Supply.
cUL
ULC-S319 Access Control Unit Power Supply. Class 1.
Physical and Environmental
Dimensions (H x W x D)
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.6mm).
Enclosure accommodates up to two (2) 12VDC/7AH batteries.
Product Weight 6.25 lbs. (2.83 kg).
Shipping Weight 7.15 lbs. (3.24 kg).
Temperature
Operating 0ºC to 49ºC (32ºF to 120ºF).
Storage -20ºC to 70ºC (-4ºF to 158ºF).
Relative Humidity 85% +/-5%.
BTU/Hr: 120 BTU/Hr.
Rev. StrikeIt4 - 06062018
StrikeIt4
(order batteries separately)
phone: +1 718.567.8181 | fax: +1 718.567.9056 | email: info@altronix.com | www.altronix.com
Altronix Corporation | 140 58th St | Brooklyn, NY 11220 USA