Altronix ReServ1WP, ReServ2WP Installation Guide

Outdoor Video Surveillance UPS
Installation Guide
Models Include:
ReServ1WP
- Twelve (12) true sine wave regulated 24VAC outputs and Four (4) regulated 12VDC outputs.
- 4A total supply current @ 24VAC and 2A total supply current @ 12VDC.
- PTC protected power-limited outputs.
ReServ2WP
- 4A total supply current.
- PTC protected power-limited outputs.
ReServ3WP
- Sixteen (16) regulated 12VDC outputs.
- 8A total supply current.
- PTC protected power-limited outputs.
Rev. 082610 More than just power.™
Overview:
ReServWP Outdoor Video Surveillance UPS units are designed to provide power for 24VAC and/or 12VDC cameras during normal or power outage conditions. True sine wave regulated AC outputs and/or regulated DC outputs.
ReServWP Series Outdoor Video Surveillance UPS Configuration Reference Chart:
Altronix Model Number
ReServ1WP
ReServ2WP
ReServ3WP
Output/Supply
Current (A)
24VAC @ 4A (100VA)
and 12VDC @ 2A
24VAC @ 3.5A (85VA)
and 12VDC @ 2A
Ambient
Temperature
-33º to 30º C
-33º to 42º C
24VAC @ 4A (100VA) -33º to 30º C
24VAC @ 3.5A (85VA) -33º to 42º C
12VDC @ 8A -33º to 42º C
Input
Rating
115VAC
60Hz,
3.5A
115VAC
60Hz,
3.5A
115VAC
60Hz,
3.5A
PTC Protected
Power-Limited
Outputs
24VAC Outputs
16 12 4
16 16 ----
16 ---- 16
Agency
12VDC Outputs
Listings
UL Listings and
File Numbers
UL File # E329542
UL 60950-1
UL/CUL Listed
for Information Technology
Equipment.
UL 60950-22
Information Technology
Equipment - Safety ­Part 22: Equipment to be Installed Outdoors
Specifications:
Output:
• PTC protected power-limited outputs are rated @ 1A.
Battery Backup:
• Built-in charger for sealed lead acid or gel type batteries.
• Automatic switchover to stand-by battery when AC fails.
Supervision:
• AC fail supervision (form “C” contacts).
• Low battery supervision (form “C” contacts).
Visual and Audio Indicators:
• AC/DC power LED indicators.
• Individual power output LED indicators.
• Low voltage input and Shutdown LED indicators.
• Audio AC Fail and Battery Fail indicator.
Additional Features:
• True sine wave regulated AC outputs (ReServ1WP and ReServ2WP). Regulated DC outputs (ReServ1WP and ReServ3WP).
• Unit maintains camera synchronization.
• Ease of installation saves time and eliminates costly labor.
Enclosure Dimensions (H x W x D):
• NEMA4 / IP66 Rated enclosure.
• Accommodates up to two (2) 12VDC/7AH batteries or two (2) 12VDC/12AH batteries.
17.375” x 12” x 6.5” (441.3mm x 304.8mm x 165.1mm).
Stand-by Specifications:
ReServ1WP - 4A (100VA) load at 24VAC and 2A load at 12VDC max.
Stand-by Batteries
ReServ2WP - 4A (100VA) max. load at 24VAC ReServ3WP - 8A (100VA) max. load at 12VDC
Two (2) 12VDC/7AH 45 minutes Two (2) 12VDC/12AH 90 minutes
Installation Instructions:
This installation should be made by qualified service personnel and should conform to all local codes and in accordance with the National Electrical Code. This product contains no serviceable parts.
1. Remove back plate inside the enclosure by removing four (4) mounting screws.
2. Mark and drill desired knockouts on the enclosure to facilitate wiring (Fig. 1, pg. 3). Note: It is required to use UL Listed outdoor rated conduit hubs with a minimum outdoor rating of 4X.
3. Secure back plate inside the enclosure with four (4) mounting screws.
4. Mount unit in the desired location with the appropriate fasteners utilizing the holes provided on the enclosure’s flanges (Pgs. 7 and 8). Secure enclosure to earth ground. Note: This product needs to be secured to the building/pole before operation.
- 2 - ReServWP
5. Connect AC power mains to the terminals marked [L] and [N], (Figs. 2-3, pg. 5-6).
Right PanelLeft Panel
Use 18 AWG or larger for all power connections (Battery, output) (Figs. 2-3, pg. 5-6). Use 18 AWG to 22 AWG for power-limited circuits (AC Fail/Low Battery reporting) (Figs. 2-3, pg. 5-6). Note: A readily accessible disconnect device shall be incorporated in the building installation wiring.
Keep power-limited wiring separate from non power-limited wiring (115VAC 60Hz Input, Battery Wires). Minimum 0.25” spacing must be provided. CAUTION: Do not touch exposed metal parts. Shut branch circuit power before installing or servicing equipment. There are no user serviceable parts inside. Refer installation and servicing to qualified service personnel.
6. The LEDs on the power supply board will illuminate when AC power is present.
7. Measure output voltage before connecting cameras/devices to outputs. This helps avoiding potential damage.
8. ReServ3WP only - Adjust voltage for every two (2) outputs using the corresponding trimpot(s) on the board prior to connecting devices.
9. Connecting cameras/devices: ReServ1WP - Connect 12VDC cameras/devices to the terminals marked [P 1-4, N 1-4] (Fig. 2, pg. 5). Connect 24VAC cameras/devices to the terminals marked [5-16] (Fig. 2, pg. 5). ReServ2WP - Connect 24VAC cameras/devices to the terminals marked [1-16] (Fig. 2, pg. 5). ReServ3WP - Connect 12VDC cameras/devices to the terminals marked [P 1-16, N 1-16] (Fig. 3, pg. 6).
10. Connect batteries to the terminals marked [-- BAT + ] (Figs. 2-3, pg. 5-6). Use two (2) 12VDC batteries connected in series for 24VDC operation (battery leads included). Use batteries - Casil CA1270 (12V/7AH), Genesis NP7-12 (12V/7AH) or NP7-12 (12V/12AH), Ultratech UT1270 (12V/7AH) or Ultratech UT12120 (12V/12AH).
11. Connect appropriate signaling notification devices to AC FAIL and BAT FAIL (Figs. 2-3, pg. 5-6) supervisory relay outputs.
12. The power LEDs on the unit for Outputs 1-16 will illuminate when AC power is present (Figs. 2-3, pg. 5-6). Note: If any of the power LEDs are not illuminated the cause may be due to the following: a. AC mains and battery fail. b. One (1) or more power output PTCs are tripped due to a short circuit or overload condition. c. Unit damaged/defective. To reset the PTC:
1. Disconnect corresponding camera/device connected to terminals marked [1-16] (Figs. 2-3, pg. 5-6).
2. Eliminate the trouble condition (short circuit or overload).
3. Allow 1 minute for PTC to cool off (reset).
4. Connect corresponding cameras/devices to terminals marked [1-16] (Figs. 2-3, pg. 5-6).
5. Power LEDs will illuminate indicating power has been restored to outputs (Figs. 2-3, pg. 5-6).
WARNING: This installation should be made by qualified service personnel and should conform to all local codes and in accordance with the National Electrical Code.
Fig. 1
Suggested Locations
for Wire Entries
Bottom Panel
ReServWP - 3 -
LED Diagnostics:
Power Supply Board
Red (DC) Green (AC1) Power Supply Status
ON ON Normal operating condition. ON OFF Loss of AC. Stand-by battery supplying power. OFF ON No DC output. OFF OFF Loss of AC. Discharged or no stand-by battery. No DC output.
ReServ Board
LED LED State Unit Status
Output LEDs
Low Battery
Shutdown
ON ------ Normal operating condition.
------ OFF Loss of 24VAC and/or 12VDC output power. ON ------ Stand-by batteries are low.
------ OFF Normal operating condition. ON ------ Loss of 24VAC and/or 12VDC output power. Discharged stand-by battery.
------ OFF Normal operating condition.
Audio Signal Diagnostics:
ReServ Unit
Audio Signal Unit Status
Single Periodic Beep AC Fail. Double Periodic Beep Low Battery or No Battery.
Terminal Identification:
Power Supply Board
Terminal Legend
L, G, N Connect 115VAC 60Hz to these terminals: L to hot, N to neutral.
-- DC + 24VDC non power-limited output.
AC FAIL NO, C, NC
BAT FAIL NO, C, NC
-- BAT + Stand-by battery connections. Maximum charge current 0.7A.
Function/Description
Form “C” dry contacts used to instantaneously signal the loss AC to local annunciation devices, with AC present terminals marked NO and C are open, NC and C are closed. When loss of AC occurs, terminals marked NO and C are closed, NC and C are open.
Form “C” dry contacts used to signal low battery voltage or loss of battery voltage. Under normal condi­tions terminals marked NO and C are open, NC and C are closed. During a trouble condition terminals marked NO and C are closed, and NC and C are open.
ReServ Board
Terminal Legend Function/Description
Input --- 24VDC + 24VDC input from power supply board. N, P 1-16 24VAC and/or 12VDC outputs.
The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open enclosure. There are no user serviceable parts inside. Refer servicing to qualified service personnel.
- 4 - ReServWP
Fig. 2 - ReServ1WP and ReServ2WP
250V
5A
Unswitched
115VAC
60Hz, 3.5A
power mains
(non power-limited)
Input
--- 24VDC +
Green
Lead
power­limited
For outputs configuration refer to Step 9, Pg. 3
of Installation Instructions
AC
DC
P
N
Non power-limited
Supervised - Non power-limited
12VDC Rechargeable Battery
(order separately)
LOW BATTERY
SHUTDOWN
9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8
Note: Two (2) 12VDC rechargeable batteries
connected in series required.
CAUTION: Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteires according to the instructions.
ReServWP - 5 -
Fig. 3 - ReServ3WP
Unswitched
115VAC
60Hz, 3.5A
power mains
(non power-limited)
250V
5A
power­limited
AC
DC
Non-power limited
1,2 V adjust
1 OUT 2
3,4 V adjust
5,6 V adjust
7,8 V adjust
P
P
P
N
N
N
3 OUT 4
5 OUT 6
7 OUT 8
12VDC
Power-Limited Outputs
Input
--- 24VDC +
9,10 V adjust
P
N
9 OUT 10
9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8
P
N
11,12 V adjust
11 OUT 12
13,14 V adjust
P
N
13 OUT 14
15,16 V adjust
P
N
15 OUT 16
P
N
Green
Lead
Supervised - Non power-limited
12VDC Rechargeable Battery
(order separately)
Note: Two (2) 12VDC rechargeable batteries
connected in series required.
CAUTION: Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteires according to the instructions.
- 6 - ReServWP
Wall Mount Installation
1- Place unit at desired location and secure with mounting screws (not included) (Fig. 4, pg. 7).
Fig. 4
Pole Mounting Using Optional Pole Mount Kit PMK1 (not included):
This installation should be made by qualified service personnel. This product contains no serviceable parts. PMK1 is in­tended for use with Altronix outdoor rated power supplies or accessories housed in WP1, WP2, WP3 and WP4 enclosures. Brackets are designed for use with the Wormgear Quick Release Straps (two included).
1. Thread one (1) wormgear quick release strap through the slots on the back of a mounting bracket (Fig. 5, pg. 7).
2. Once the desired height of the top Pole Mount bracket is achieved, tighten the straps down by sliding open end of the strap through the locking mechanism on the strap, then tighten the screw with flat head screwdriver or 5/16” hex socket driver (Fig. 6, pg. 7).
Fig. 7
Fig. 5
Fig. 6
3. Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the bracket, tightening bolts with a 7/16” hex socket (Fig. 8, pg. 7).
4. Thread the second wormgear quick release strap through the slots on the back of the bottom mounting bracket (Fig. 8, pg. 7).
5. Mount enclosure onto the top bracket by inserting bolts through flange of the enclosure and into the bracket, tightening bolts with a 7/16” hex socket (Fig. 9, pg. 7).
6. Tighten the straps of the bottom bracket down by sliding the open end of the strap through the locking mechanism on the strap, then tighten screw with flat head screwdriver or 5/16” hex socket driver (Fig. 9/9a, pg. 7).
7. Clip excess straps.
Fig. 9 - 2” to 8”(50.8mm to 203.2mm) Fig. 9a - 5” (127mm) square pole diameter round pole
Fig. 8
ReServWP - 7 -
NEMA4/IP66 rated enclosure.
Enclosure Dimensions (H x W x D approximate):
17.375” x 12” x 6.5” (441.3mm x 304.8mm x 165.1mm)
165.1mm
6.5’’
114.3mm
4.5’’
304.8mm
254mm
10’’
12’’
406mm
16’’
441.3mm
17.375’’
276.2mm
10.875’’
425.45mm
16.75’’
377.83mm
14.875’’
12.7mm
0.5’’
7.9375mm
0.3125’’
Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 website: www.altronix.com, e-mail: info@altronix.com. Lifetime Warranty, Made in U.S.A. IIReServWP F16P
- 8 - ReServWP