RBUL - UL Listed Sensitive Relay Module
--- (NEG)
POS + C
NC
NO
RBUL
CUT J1
FOR 24V
J1
LISTED
SECURITY
SUBASSEMBLY
8D40
--- (N EG)
POS + C
NC
NO
RBUL
CUT J1
FOR 24V
J1
TO BELL OUTPUT TERMINALS
OF CONTROL PANEL
+
--
Specifications:
• UL Listed Burglar Alarm System SubAssembly (UL365).
• 12VDC or 24VDC selectable operation.
• Current draw 30mA.
• 1 amp/28VDC SPDT contacts.
• Includes snap track (ST1).
Board dimensions: 2.75"L x 2"W x 1"H
Installation Instructions:
1. Mount relay in desired enclosure. Secure snap track with screws.
Be sure to provide enough clearance between PC board and
snap track mounting screw head to avoid short circuit.
2. Connect DC input to terminals marked [+ (POS) ] and [ ---(NEG) ].
3. For 24VDC operation cut J1 on relay module.
Dry Contacts
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
website: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A.
IIRBUL - Rev. 061808 B11I