![](/html/ba/bab4/bab41e6bfc7ffa2e7634548fbe77f62a1c1c6388e98ad760dcb69a7399aa5686/bg1.png)
RBTUL - UL Listed Ultra Sensitive Relay Module
--- (NEG)
TRG
POS + C
NC
NO
CUT J1
FOR 24V
J1
--- (NEG)
TRG
POS + C
NC
NO
RBTUL
CUT J1
FOR 24V
J1
+
--
TO CONSTANT AUXILIARY POWER
12VDC OR 24VDC
+TRG
3VDC TO
24VDC
LISTED
SECURITY
SUBASSEMBLY
8D40
Specifications:
• UL Listed Burglar Alarm System SubAssembly (UL 365).
• 12VDC or 24VDC selectable operation.
• Current drwa 30mA.
• 3VDC to 24VDC 2mA positive (+) trigger.
• 1 amp/28VDC SPDT contacts.
• Includes snap track (ST1).
Board dimensions: 2.75"L x 2"W x 1"H
Installation Instructions:
1. Mount relay in desired enclosure. Secure snap track with screws.
Be sure to provide enough clearance between PC board and
snap track mounting screw head to avoid short circuit.
2. Connect DC input to terminals marked [+ (POS) ] and [ ---(NEG) ].
3. Connect DC + positive input trigger to terminal marked [TRG].
Note: If using isolated trigger connect neg
4. For 24VDC operation cut J1 on relay module.
ative (--) side of trigger voltage to terminal marked [(NEG) ---].
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
website: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A.