Altronix R615DC416ULCB, R615DC616UL, R615DC616ULCB, R615DC8UL, R615DC416UL Installation Guide

Rack Mount Series
UL Listed CCTV Power Supplies
Installation Guide
Models Include:
• R615DC8UL • R615DC8ULCB
- 6-15VDC @ 4A. - 6-15VDC @ 4A.
- Eight (8) Fuse Protected - Eight (8) PTC Protected Outputs. Outputs.
• R615DC416UL • R615DC416ULCB
- 6-15VDC @ 4A. - 6-15VDC @ 4A.
- Sixteen (16) Fuse Protected - Sixteen (16) PTC Protected Outputs. Outputs.
• R615DC616UL • R615DC616ULCB
- 6-15VDC @ 6A. - 6-15VDC @ 6A.
- Sixteen (16) Fuse Protected - Sixteen (16) PTC Protected Outputs. Outputs.
Rev. 050106
Overview:
These Altronix Rack Mount CCTV Power Supplies provide 6-15VDC distributed via eight (8) or sixteen (16) fuse or PTC protected outputs for powering CCTV Cameras, heaters and other video accessories.
R615DCUL Rack Mount Configuration Reference Chart:
Class 2
Altronix Model Number
R615DC8UL R615DC8ULCB R615DC416UL R615DC416ULCB R615DC616UL R615DC616ULCB
Total
Output Current (Power)
4A 6-15VDC 8 4A 6-15VDC 8 4A 6-15VDC 16 4A 6-15VDC 16 6A 6-15VDC 16 - ­6A 6-15VDC 16
Output
Voltage
Number
of
Outputs
Rated
Power­Limited Outputs
P P P P P P
P P
PTC
Protected
Outputs
-
-
Output
Fuse
Protected
Outputs
P
- 2.5A 0.9A
P
- 2.5A 0.9A
P
- 2.5A 1.5A
Current
(max per
output)
3.5A 0.9A
3.5A 0.9A
3.5A 1.5A
115VAC
50/60Hz
Input
Current
Specifications:
Agency Listings:
• UL Listed for Commercial CCTV Equipment (UL 2044). CUL Listed - CSA Standard C22.2 No.1-98, Audio, Video and Similar Equipment.
Input:
• 115VAC, 50/60Hz.
Output:
• Eight (8) or sixteen (16) fuse or PTC protected outputs
• 6-15VDC output.
• Outputs are rated @ 3.5A (fused) or 2.5A (PTC).
• Filtered and electronically regulated outputs.
• Short circuit and thermal overload protection.
Features:
• Individual power LED indicators.
• Illuminated master power disconnect circuit breaker with manual reset.
• Removable terminal blocks with locking screw flange.
• Removable faceplate and sliding rear section for easy access.
Rack Dimensions:
• 2U rack mount chassis for use in standard EIA 19” rack.
• Rack dimensions (H x W x D approx.):
3.26” x 19.125” x 8.5” (83mm x 486mm x 216mm).
Caution: This installation should be made by qualified service personnel and should conform to all local codes and the National Electrical Code.
Installation Instructions:
1. Unit is factory set at 12VDC. To adjust the output voltage remove the top cover to access trimpot on the power supply board (Fig. 1b, pg. 3).
2. Mount unit in the desired rack location (Space unit at least 3” from any video monitors).
3. Set power switch on the back of the unit to the OFF position (Fig. 1e, pg. 3).
4. Plug the power cord into a grounded 115VAC 50/60 Hz receptacle (Fig. 1d, pg. 3).
5. Set power switch to the ON (RESET) position and measure output voltage before connecting devices (Fig. 1e, pg. 3). This helps avoiding potential damage. CAUTION: Determine the maximum operating voltage of the equipment being powered before adjusting the
output voltage.
6. Set power switch on the back of the unit to the OFF position (Fig. 1e, pg. 3).
7. Connect devices to the removable terminal blocks marked [1P & 1N] through [8P & 8N] or [1P & 1N] through [16P & 16N], where applicable (Fig. 1c, pg. 3). When wiring is completed on the terminal blocks, they can be locked down by tightening screw flanges. All terminals with common suffix (P) “1P, 2P...” are the same polarity (positive). All terminals with common suffix (N) “1N, 2N...” are the same polarity (negative).
8. Upon completion of the wiring, set power switch on the back of the unit to the ON (RESET) position (Fig. 1e, pg. 3).
9. Green power LEDs on faceplate will illuminate when DC output power is present. When an output is in a trouble condition (blown fuse or tripped PTC), the corresponding LED will not be illuminated (Fig. 1, pg. 3). a. Blown fuse (R615DC416UL, R615DC616UL, and R615DC8UL) - Set power switch on the back of unit to the OFF position (Fig. 1e, pg. 3). Remove front faceplate to access fuses. Replace with fuses rated @ 3.5A/250VA (Altronix model # Fuse1).
- 2 - R615DCUL Series