Rack Mount Series
CCTV Power Supplies
Installation Guide
Models Include:
• R248100 • R248100CB
- 24VAC @ 4 amp (100VA) - 24VAC @ 4 amp (100VA)
or 28VAC @ 3.5 amp (100VA). or 28VAC @ 3.5 amp (100VA).
- Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.
• R248300 • R248300CB
- 24VAC @ 14 amp (300VA) - 24VAC @ 14 amp (300VA)
or 28VAC @ 12.5 amp (300VA). or 28VAC @ 12.5 amp (300VA).
- Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.
• R248600 • R248600CB
- 24VAC @ 28 amp (600VA) - 24VAC @ 28 amp (600VA)
or 28VAC @ 25 amp (600VA). or 28VAC @ 25 amp (600VA).
- Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.
Rev. 120809

Overview:
These Altronix Rack Mount CCTV Power Supplies provide 24VAC or 28VAC distributed via eight (8) fuse or PTC
protected outputs for powering CCTV Cameras, heaters and other video accessories.
Altronix
Model Number
R248100
R28100CB
R248300
R28300CB
R248600
R248600CB
Eight (8) Output Rack Mount Configuration Reference Chart:
Output
Voltage
(VAC)
24VAC 4 amp
28VAC 3.5 amp
24VAC 4 amp
28VAC 3.5 amp
24VAC 14 amp
28VAC 12.5 amp
24VAC 14 amp
28VAC 12.5 amp
24VAC 28 amp
28VAC 25 amp
24VAC 28 amp
28VAC 25 amp
Total Output
Current
(Power)
Number of
Outputs
8 --- Yes 3.5 amp 2.9 amp
8 Yes --- 2.5 amp 2.9 amp
8 --- Yes 3.5 amp 3 amp
8 Yes --- 2.5 amp 3 amp
8 --- Yes 3.5 amp 6 amp
8 Yes --- 2.5 amp 6 amp
Specifications:
Input:
• 115VAC,50/60Hz.
Output:
• Eight (8) fuse or PTC protected outputs.
• 24VACor28VACsupplycurrent.
• Outputs are rated @ 3.5 amp (fuse) or 2.5 amp (PTC).
• Surgesuppression.
Features:
• Eight(8)powerLEDs.
• Illuminatedmasterpowerdisconnectcircuitbreaker
with manual reset.
PTC
Protected
Outputs
Fuse
Protected
Outputs
Individual Output
Current
(max per output -
not to exceed total
output current)
115VAC
50/60Hz Input
Current
Features (cont’d):
• Removableterminalblockswithlockingscrewflange.
• Spare fuses provided.
• Unitmaintainscamerasynchronization.
Mechanical:
• 2UrackmountchassisforuseinstandardEIA19”rack.
• EnclosureDimensions(HxWxDapprox.):
3.26” x 19.125” x 8.5” (83mm x 486mm x 216mm).
Installation Instructions:
1. Mount unit in the desired rack location (Space unit at least 3” from any video monitors). Do not obstruct side air vents.
2. Set power disconnect circuit breaker to OFF position (Fig. 1c, pg. 3).
3 All units are factory set for 24VAC operation.
For 28VAC operation, adjust unit prior to mounting and applying power as follows:
Change the wire position so that the black wire [28V] is connected to the terminal marked [P] and
the yellow wire [24V] is connected to the terminal marked [S] (Fig. 1, pg. 3).
4. Plug power cord into a grounded 115VAC 50/60 Hz receptacle (Fig. 1b, pg. 3), ground should be connected
as indicated in (Fig. 1d, pg. 3).
5. Set power disconnect circuit breaker to RESET (ON) position (Fig. 1c, pg. 3).
6. Measure output voltage before connecting devices. This helps avoiding potential damage.
All terminals with common suffix (P) “1P, 2P...” are the same polarity.
7. Set power disconnect circuit breaker to OFF position (Fig. 1c, pg. 3).
8. Connect devices to the removable terminal blocks marked [1P & 1N through 8P & 8N] (Fig. 1a, pg. 3).
When wiring is completed on terminal blocks, they can be locked down by tightening screw flanges.
9. Upon completion of wiring, set power disconnect circuit breaker to RESET (ON) position (Fig. 1c, pg. 3).
10. Green power LEDs on faceplate will illuminate when power is present. When an output is in a trouble condition
- 2 - R248 series
(blown fuse or tripped PTC), the corresponding LED will not be illuminated (Fig. 1, pg. 3).

a. Blown fuse - Set power disconnect circuit breaker on the back of the unit to the OFF position (Fig. 1c, pg. 3).
Remove front faceplate to access fuses. Replace with fuses rated @ 3.5A/250VA (Altronix model # Fuse1).
b. Tripped PTC - To reset PTC, set power disconnect circuit breaker on back of unit to the OFF position.
After approximately 30 secs. set power disconnect circuit breaker to the ON (RESET) position (Fig. 1c, pg. 3).
11. Illuminated power disconnect circuit breaker with manual reset:
OFF position - Switch not illuminated. Outputs not powered.
RESET (ON) position - Circuit breaker illuminated. Outputs powered.
Circuit breaker tripped - Circuit breaker is not illuminated. Power LEDs on faceplate are not illuminated.
Outputs not powered.
To reset circuit breaker set power disconnect circuit breaker to RESET (ON) position (Fig. 1c, pg. 3).
CAUTION: Equipment must be installed/serviced by authorized personnel only.
Shut brunch circuit power before servicing/installing equipment.
Fig. 1 Fig. 1a Fig. 1b Fig. 1c
Removable Terminal
Block
N
PS
ALTRONIX CORP.
BROOKLYN, NY 11220
MADE IN USA
PTC1
N
P
S
Strain Relief
Line Cord
Power Switch
XFMR*XFMR*
Used
on PTC
Models
AC Power
LED's
AC Power
LED's
24VAC Output
(Factory Set)
SP N
28VAC Output
SP N
(Green Wire
Earth GND)
Fig. 1d
28VAC (Black)
24VAC (Yellow)
COM (Brown)
R248 series - 3 -
24VAC (Yellow)
28VAC (Black)
COM (Brown)

WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture.
This installation should be made by qualified service personnel and should conform to the National
Electrical Code and all local codes.
The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the
presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient
magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open enclosure. There are
no user serviceable parts inside. Refer servicing to qualified service personnel.
Rack Mechanical Drawing and Dimensions:
3.26” x 19.125” x 8.5” (83mm x 486mm x 216mm)
19.125”
(485.78mm)
17.5”
(444.5mm)
2.95”
(74.93mm)
(215.9mm)
8.5”
0.65”
(16.51mm)
Front View
Bottom View
2.52”
(64mm)
RESET
1.5”
(38mm)
1.0”
(25.4mm)
Rear View
3.26”
(83mm)
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
web site: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A.
- 4 - R248 series
IIR248Series J07M
OFF
8 7
6
5
N P N PN PN P N PN PN PN P
4 3
2
1
MEMBER