Rack Mount Series
UL Listed CCTV Power Supplies
Installation Guide
Models Include:
• R2416UL • R2416ULCB
- 24VAC @ 7A (170VA) - 24VAC @ 7A (170VA)
or 28VAC @ 6A (170VA). or 28VAC @ 6A (170VA).
- Sixteen (16) Fuse Protected Outputs. - Sixteen (16) PTC Protected Outputs.
• R2416300UL • R2416300ULCB
- 24VAC @ 12.5A (300VA) - 24VAC @ 12.5A (300VA)
or 28VAC @ 10A (280VA). or 28VAC @ 10A (280VA).
- Sixteen (16) Fuse Protected Outputs. - Sixteen (16) PTC Protected Outputs.
• R2416600UL • R2416600ULCB
- 24VAC @ 25A (600VA) - 24VAC @ 25A (600VA)
or 28VAC @ 20A (560VA). or 28VAC @ 20A (560VA).
- Sixteen (16) Fuse Protected Outputs. - Sixteen (16) PTC Protected Outputs.
Rev. 040506

Overview:
These Altronix Rack Mount CCTV Power Supplies provide 24VAC or 28VAC distributed via sixteen (16) fuse or PTC
protected outputs for powering CCTV Cameras, heaters, and other video accessories.
Sixteen (16) Output Rack Mount Configuration Reference Chart:
Altronix
Output Voltage
Model Number
R2416UL
R2416ULCB
R2416300UL
R2416300ULCB
R2416600UL*
R2416600ULCB
*24VAC models: Outputs 1-8 provide 12.5A (300VA) max. Outputs 9-16 provide 12.5A (300VA) max.
*28VAC models: Outputs 1-8 provide 10A (280VA) max. Outputs 9-16 provide 10A (280VA) max.
(VAC)
24VAC 7A
28VAC 6A
24VAC 7A
28VAC 6A
24VAC 12.5A
28VAC 10A
24VAC 12.5A
28VAC 10A
24VAC 25A
28VAC 20A
24VAC 25A
28VAC 20A
Total Output Current
(Power)
Number of Outputs
PTC Protected Outputs
16
16
16
16
16
16
(Class 2 power-limited for
Dry locations, Class 3 for
Wet locations)
Fuse Protected
Class 1 Outputs
Individual Output Current
(max per output not to
exceed total output current)
P
P
P
P
P
P
3.5A 3.5A
2.5A
3.5A 3.5A 3A
2.5A 3A
3.5A 3.5A 6A
2.5A 6A
Fuse Ratings
Primary In-Line
Fuse Ratings
3.5A/
250V
3.5A/
250V
115VAC 50/60Hz Input
Current
2.9A
2.9A
Agency
Listings
Specifications:
Agency Listings:
• UL Listed for Commercial CCTV Equipment (UL 2044).
CUL Listed - CSA Standard C22.2 No. 1-98, Audio,
Video and Similar Equipment.
• CE European Conformity
Output:
• 24VAC or 28VAC outputs (Factory set @ 24VAC).
• Surge suppression.
• Filtered and electronically regulated output.
• Short circuit and thermal overload protection.
Visual Indicators:
• Sixteen (16) individual power LED indicators.
• Illuminated power disconnect circuit breaker
with manual reset.
Features:
• Unit maintains camera synchronization.
• Ease of installation saves time and eliminates costly labor.
• Removable terminal blocks with locking screw flanges.
Rack Dimensions (H x W x D):
• 2U rack mount chassis for use in standard EIA 19” rack.
3.26” x 19.125” x 8.5” (83mm x 486mm x 216mm)
Installation Instructions:
1. Mount unit in the desired rack location (Space unit at least 3” from any video monitors). Do not obstruct side air vents.
2. Set power disconnect circuit breaker to OFF position (Fig. 1d, pg. 3).
3. The unit is factory set for 24VAC operation.
For 28VAC operation, adjust unit prior to mounting and applying power as follows:
a. Open bottom of the unit by removing six (6) screws (Rack Mechanical Drawing and Dimensions, pg. 4).
b. Change the wire position so that the black wire [28V] is connected to the terminal marked [P] and
the yellow wire [24V] is connected to the terminal marked [S].
c. After securing all wires for proper voltage place bottom panel back on the unit and fasten with the six (6) screws.
Note: R2416ULCB set for 28VAC operation is not Class 2 Rated, not power-limited.
4. Plug power cord into a grounded 115VAC 50/60 Hz receptacle (Fig. 1c, pg. 3), ground should be connected
- 2 - R2416ULseries
as indicated in (Fig. 1e, pg. 3).

Fig. 1
Class 2 Rated Power-Limited Outputs.
Except for R2416UL, R2416300UL,
R2416600UL and R2416ULCB when
set for 28VAC.
Fig. 1a
Removable Terminal
Block
Fig. 1b Fig. 1c
Fuse
Fuse
Strain Relief
Line Cord
Fig. 1d
Power Disconnect
Circuit Breaker with
Illuminated
manual reset
PTC1
Used
on PTC
Models
N
PS
ALTRONIX CORP.
BROOKLYN, NY 11220
MADE IN USA
AC Power
LED's
AC Power
LED's
XFMR*
AC Power
LED's
AC Power
LED's
Fig. 1e
N
P
S
XFMR*
Divider
24VAC Output
(Green Wire
Earth GND)
(Factory Set)
SP N
28VAC (Black)
24VAC (Yellow)
COM (Brown)
28VAC Output
SP N
28VAC (Black)
24VAC (Yellow)
COM (Brown)
5. Set power disconnect circuit breaker to RESET (ON) position (Fig. 1d, pg. 3).
6. Measure output voltage before connecting devices. This helps avoiding potential damage.
All terminals with common suffix (P) “1P, 2P...” are the same polarity.
7. Set power disconnect circuit breaker to OFF position (Fig. 1d, pg. 3).
8. Connect devices to the removable terminal blocks marked [1P & 1N] through [16P & 16N] (Fig. 1a, pg. 3).
When wiring is completed on the terminal blocks they can be locked down by tightening screw flanges.
9. Upon completion of the wiring, set power disconnect circuit breaker to RESET (ON) position (Fig. 1d, pg. 3).
10. Green power LEDs on faceplate will illuminate when power is present. When an output is in
a trouble condition (blown fuse or tripped PTC) the corresponding LED will not be illuminated (Fig. 1, pg. 3).
a. Blown fuse (R2416UL, R2416300UL, and R2416600UL) - Set power disconnect circuit breaker on the back
of the unit to the OFF position (Fig. 1e, pg. 3).
Remove front faceplate to access fuses. Replace with fuses rated @ 3.5A/250VA (Altronix model # Fuse1).
b. Tripped PTC (R2416ULCB, R2416300ULCB, and R2416600ULCB) - To reset PTC, set power switch on the back
of the unit to the OFF position. After approximately 30 secs. set power disconnect circuit breaker to
the ON (RESET) position (Fig. 1d, pg. 3).
11. Illuminated power disconnect circuit breaker with manual reset:
OFF position - Switch not illuminated. Outputs not powered.
RESET (ON) position - Circuit breaker illuminated. Outputs powered.
Circuit breaker tripped - Circuit breaker is not illuminated. Power LEDs on faceplate are not illuminated.
Outputs not powered.
To reset circuit breaker set power disconnect circuit breaker to RESET (ON) position (Fig. 1d, pg. 3).
Note: Do not exceed unit’s electrical load ratings as indicated in reference chart (pg. 2).
Do not place mechanical load on the unit. Unit is designed optimally for normal data room office installations.
Data racks should always be properly ventilated.
R2416ULseries - 3 -

WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This
installation should be made by qualified service personnel and should conform to all local codes and in
accordance with the National Electrical Code.
For fuse protected models:
3.5A
Replace fuses with the same type and rating 3.5A/250V.
250V
The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the
presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient
magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open enclosure. There are
no user serviceable parts inside. Refer servicing to qualified service personnel.
Rack Mechanical Drawing and Dimensions
3.26” x 19.125” x 8.5” (83mm x 486mm x 216mm)
View from back
3.26"
82.8mm
8.5"
215.9mm
BACK
17.625"
447.8mm
BOTTOM
View from front
FACEPLATE
19.125"
0.75"
19.05mm
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
web site: www.altronix.com, e-mail: info@altronix.com. Lifetime Warranty, Made in U.S.A.