Altronix R2416600UL, R2416600ULCB, R2416UL, R2416300UL, R2416300ULCB Installation Guide

Rack Mount Series
UL Listed CCTV Power Supplies
Installation Guide
Models Include:
• R2416UL • R2416ULCB
- 24VAC @ 7A (170VA) - 24VAC @ 7A (170VA) or 28VAC @ 6A (170VA). or 28VAC @ 6A (170VA).
• R2416300UL • R2416300ULCB
- 24VAC @ 12.5A (300VA) - 24VAC @ 12.5A (300VA) or 28VAC @ 10A (280VA). or 28VAC @ 10A (280VA).
- Sixteen (16) Fuse Protected Outputs. - Sixteen (16) PTC Protected Outputs.
• R2416600UL • R2416600ULCB
- 24VAC @ 25A (600VA) - 24VAC @ 25A (600VA) or 28VAC @ 20A (560VA). or 28VAC @ 20A (560VA).
Rev. 040506
Overview:
These Altronix Rack Mount CCTV Power Supplies provide 24VAC or 28VAC distributed via sixteen (16) fuse or PTC protected outputs for powering CCTV Cameras, heaters, and other video accessories.
Sixteen (16) Output Rack Mount Configuration Reference Chart:
Altronix
Output Voltage
Model Number
R2416UL
R2416ULCB
R2416300UL
R2416300ULCB
R2416600UL*
R2416600ULCB
*24VAC models: Outputs 1-8 provide 12.5A (300VA) max. Outputs 9-16 provide 12.5A (300VA) max. *28VAC models: Outputs 1-8 provide 10A (280VA) max. Outputs 9-16 provide 10A (280VA) max.
(VAC)
24VAC 7A 28VAC 6A 24VAC 7A 28VAC 6A 24VAC 12.5A 28VAC 10A 24VAC 12.5A 28VAC 10A 24VAC 25A 28VAC 20A 24VAC 25A 28VAC 20A
Total Output Current
(Power)
Number of Outputs
PTC Protected Outputs
16
16
16
16
16
16
(Class 2 power-limited for
Dry locations, Class 3 for
Wet locations)
Fuse Protected
Class 1 Outputs
Individual Output Current
(max per output not to
exceed total output current)
P
P
P
P
P
P
3.5A 3.5A
2.5A
3.5A 3.5A 3A
2.5A 3A
3.5A 3.5A 6A
2.5A 6A
Fuse Ratings
Primary In-Line
Fuse Ratings
3.5A/ 250V
3.5A/ 250V
115VAC 50/60Hz Input
Current
2.9A
2.9A
Agency
Listings
Specifications:
Agency Listings:
• UL Listed for Commercial CCTV Equipment (UL 2044). CUL Listed - CSA Standard C22.2 No. 1-98, Audio, Video and Similar Equipment.
• CE European Conformity
Output:
• 24VAC or 28VAC outputs (Factory set @ 24VAC).
• Surge suppression.
• Filtered and electronically regulated output.
• Short circuit and thermal overload protection.
Visual Indicators:
• Sixteen (16) individual power LED indicators.
• Illuminated power disconnect circuit breaker with manual reset.
Features:
• Unit maintains camera synchronization.
• Ease of installation saves time and eliminates costly labor.
• Removable terminal blocks with locking screw flanges.
Rack Dimensions (H x W x D):
• 2U rack mount chassis for use in standard EIA 19” rack.
3.26” x 19.125” x 8.5” (83mm x 486mm x 216mm)
Installation Instructions:
1. Mount unit in the desired rack location (Space unit at least 3” from any video monitors). Do not obstruct side air vents.
2. Set power disconnect circuit breaker to OFF position (Fig. 1d, pg. 3).
3. The unit is factory set for 24VAC operation. For 28VAC operation, adjust unit prior to mounting and applying power as follows: a. Open bottom of the unit by removing six (6) screws (Rack Mechanical Drawing and Dimensions, pg. 4). b. Change the wire position so that the black wire [28V] is connected to the terminal marked [P] and the yellow wire [24V] is connected to the terminal marked [S]. c. After securing all wires for proper voltage place bottom panel back on the unit and fasten with the six (6) screws.
Note: R2416ULCB set for 28VAC operation is not Class 2 Rated, not power-limited.
4. Plug power cord into a grounded 115VAC 50/60 Hz receptacle (Fig. 1c, pg. 3), ground should be connected
- 2 - R2416ULseries
as indicated in (Fig. 1e, pg. 3).