Altronix MAXFIT7FE, MAXFIT5FE, MAXFIT3FE Specsheet

MaxFit FE Series
Single P/S Expandable Power Systems
Description
Altronix MaxFit FE Single Power Supply Expandable Power Systems provide system
designers and installers with optimum power choices and the highest levels of ver-
satility in a more compact and economical enclosure. Units provide 12VDC or 24VDC
via single output power supply/charger and include AC fail, low battery, and battery
presence monitoring. Enclosure accommodates up to four (4) 12VDC/12AH batteries.
Key Features
MaxFit7FE
- Filtered and electronically regulated outputs.
- Additional aux. Class 2 power-limited output rated @ 1A.
- Supervision
- AC Fail
- Low Battery and Battery Presence
- Low power shutdown.
- Supervised fire alarm disconnect.
MaxFit FE Series Power Supply Configuration Reference Chart
120VAC 60Hz Altronix Model Number
MaxFit3FE
MaxFit5FE
MaxFit7FE
Input
Current
3.5A 5A/250V 10A/32V 10.0-13.2 20.19-26.4 10.03-13.2 20.19-26.4 6A
3.5A 5A/250V 15A/32V 10.03-13.2 10.03-13.2 10A
4.5A 6.3A/250V 15A/32V 20.17-26.4 20.17-26.4 10A
Input Fuse
Rating
Battery Fuse
Rating
12VDC Output
Range (V)
- Built-in 30-50% faster charger for sealed lead acid or gel type batteries.
- Low power cutoff - protects stand-by batteries from deep discharge.
- AC input and DC output LED indicators.
- Enclosure accommodates up to four (4) 12VDC/12AH batteries.
- Lifetime Warranty / Made in the U.S.A.
Nominal DC Output Voltage Options
[DC] [AUX]
24VDC Output
Range (V)
12VDC Output
Range (V)
24VDC Output
Range (V)
Maximum Supply
Current for Main
and Aux. Outputs
Rev. MaxFitFE - 101619
MaxFit FE Series
Single P/S Expandable Power Systems
Specifications
Input
Voltage 120VAC, 60Hz. Fusing Varies, see Reference Chart.
Indicators (LED)
Input 120VAC is present. DC Output Powered.
Outputs
Voltage 12VDC or 24VDC, see Reference Chart. Current Varies, see Reference Chart. Other Overvoltage protection.
Filtered and regulated.
Back-up Battery (not included)
Capacity 12AH / 12VDC (Up to 4 within enclosure). 40 AH / 65 AH (requires separate enclosure).
Type Sealed lead acid or gel type. Fuse Rating Varies, see Reference Chart. Failover Upon AC loss, instantaneous.
Fire Alarm Disconnect
Supervised Latching or non latching. EOL 10K Resistor.
Supervision
AC Failure Form “C” contacts. Battery Form “C” contacts. Low DC Power Shutdown
Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
Physical and Environmental
Dimensions (H x W x D)
20.5” x 16.5” x 6.25” (520.7mm x 419.1mm x 158.8mm).
Weight (approx.):
Model Product Weight Shipping Weight
MaxFit3FE 20.3 lb. (9.2 kg) 25.7 lb. (11.6 kg) MaxFit5FE 20.3 lb. (9.2 kg) 25.7 lb. (11.6 kg) MaxFit7FE 20.6 lb. (9.3 kg) 26 lb. (11.8 kg)
Temperature Operating 0ºC to 49ºC (32ºF to 120ºF). Storage -20ºC to 70ºC (-4ºF to 158ºF). Relative Humidity 85% +/-5%. BTU/Hr (approx.):
Model 12VDC 24VDC
MaxFit3FE 37 74 MaxFit5FE 61 N/A MaxFit7FE N/A 123
Accessories
Network Supervision
Altronix model LINQ2 Network Communication Module provides remote supervision,
control and monitoring over LAN/WAN
- Remotely reports accurate power diagnostics
- Controls power and resets devices
- Reports system diagnostics via Email
phone: +1 718.567.8181 | fax: +1 718.567.9056 | email: info@altronix.com | www.altronix.com