LPD - Low Power Disconnect Module
--- OUT +
SW2
+ INPUT ---
DEVICES
(Max. 8 amps)
DC
OUTPUT
--+
--+
SW1
Specifications:
• Input voltage: 12VDC or 24VDC max. 8 amps.
• Low voltage cutoff: 12VDC: 10.5 volts (+/--- 0.3 volts) 24VDC: 20 volts (+/--- 0.3 volts).
• Restore voltage threshold: 12VDC: 11.5 volts (+/--- 0.3 volts) 24VDC: 23 volts (+/---0.3 volts).
• Relay contact rating 8 amp max.
Board dimensions: 2.75"L x 2.2"W x 1"H
Operation:
Normal Condition: INPUT + connects via relay contact to OUTPUT +.
Low Voltage disconnect: INPUT + from OUTPUT + during low voltage cutoff.
Note: INPUT --- remains connected to OUTPUT --- at all times.
Voltage Selection Chart:
Output Voltage SW1 SW2
12VDC Open Closed
24VDC Closed Open
Installation Instructions:
1. Mount LPD in desired location/enclosure.
2. Set the LPD to desired operating voltage via SW1 & SW2 (see Voltage Selection Chart).
3. Connect output from power supply to terminals marked [+ INPUT --- ].
4. Connect devices to be powered to terminals marked [--- OUT +].
Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
web site: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A.
IILPD - Rev. 062408
MEMBER