Active UTP Transceiver Hub
with Integral Camera Power
Installation Guide
Models Include:
HubWayLD8DHubWayLD16D
- UL Listed eight (8) Channel Active UTP- UL Listed sixteen (16) Channel Active UTP
Transceiver Hub with Integral Camera PowerTransceiver Hub with Integral Camera Power
HubWayLD82DHubWayLD162D
- UL Listed eight (8) Channel Active UTP- UL Listed sixteen (16) Channel Active UTP
Transceiver Hub with Integral Camera PowerTransceiver Hub with Integral Camera Power
- Includes eight (8) UL Listed Accessory - Includes sixteen (16) UL Listed Accessory
HubWayAv Video Balun/CombinersHubWayAv Video Balun/Combiners
HubWayLD83DHubWayLD163D
- UL Listed eight (8) Channel Active UTP- UL Listed sixteen (16) Channel Active UTP
Transceiver Hub with Integral Camera PowerTransceiver Hub with Integral Camera Power
- Includes eight (8) UL Listed Accessory - Includes sixteen (16) UL Listed Accessory
HubWayDv Video Balun/CombinersHubWayDv Video Balun/Combiners
Rev. 030408
More than just power.
TM
Overview:
Altronix HubWayLD8D/16D Active UTP Transceiver Hub w/Integral Camera Power transmits UTP video, RS422/RS485
data and power over a single CAT-5 or higher structured cable. Unit provides 8 or 16 camera channels in a space saving
1U EIA 19” rack mount chassis which may be rack, wall or shelf mounted. Video transmission range is up to 3000 ft.
max. per channel. Units are compatible with AC and/or DC fixed or PTZ cameras when utilizing Altronix HubWayAv,
HubWayDv or HubWayDvi Video Balun/Combiners. In addition, the unit features individually selectable 24VAC or
28VAC PTC protected outputs with surge suppression. An optional HubSat4D Passive UTP Transceiver Hub with Integral
Camera Power can be used as an accessory module to transmit video from up to 4 cameras over a single CAT-5 or higher
structured cable back to the HubWayLD8D/16D. In addition, the HubSat4D provides power to these cameras locally to
eliminate the possibility of voltage drop associated with long cable runs.
HubWayLD Specifications:
HubWayLD8D/LD82D/LD83D
Input:
• 115VAC 60Hz, 1.5 amp or
230VAC 50/60Hz, 1 amp.
Video:
• Eight (8) channels of video over twisted pair up to
a distance of 3000 ft. per channel.
• Eight (8) 75 ohm video outputs.
Power:
• Unit provides up to 1 amp max. per channel not to
exceed a total of 5 amp (150VA) maximum current.
HubWayLD16D/LD162D/LD163D
Input:
• 115VAC 60Hz, 3 amp or
230VAC 50/60Hz, 1.5 amp.
Video:
• Sixteen (16) channels of video over twisted pair up to
a distance of 3000 ft. per channel.
• Sixteen (16) 75 ohm video outputs.
Power:
• Unit provides up to 1 amp max. per channel not to
exceed a total of 10 amp (300VA) maximum current.
Common Specifications:
Agency Listings:
• UL Listed for Commercial CCTV
Equipment (UL 2044).
Data:
• RS422/RS485 data inputs.
Power:
• Individually selectable 24VAC or 28VAC power outputs
with OFF position.
• PTC protected outputs.
• PTCs are rated @ 1 amp per channel.
• Surge suppression.
Visual Indicators:
• AC input power indicator.
• Video signal and power LED indicators.
Additional Models:
HubW
ayLD82D
• HubWayLD8D with eight (8) UL Listed Accessory
HubWayAv Video Balun/Combiners for 24VAC Cameras.
HubWayLD83D
• HubWayLD8D with eight (8) UL Listed Accessory
HubWayDv Video Balun/Combiners for 12VDC Cameras.
Features:
• Picture and Gain control.
• Illuminated master power disconnect circuit breaker
with manual reset.
• IEC 320 - 3-wire grounded line cord (detachable).
• Unit can be rack, wall or shelf mounted.
• 1U rack mount chassis for use in standard EIA 19” rack.
Accessories:
• Video Balun/Combiners:
- HubWayAv - for use with 24VAC cameras.
- HubWayDv - for use with 12VDC cameras.
- HubWayDvi - for use with non-isolated 12VDC cameras.
• Optional HubSat4D allows transmission of up to
four (4) video signals over a single CAT-5 or higher
structured cable.
HubWayLD162D
• HubWayLD16D with sixteen (16) UL Listed Accessory
HubWayAv Video Balun/Combiners for 24VAC Cameras.
HubWayLD163D
• HubWayLD16D with sixteen (16) UL Listed Accessory
HubWayDv Video Balun/Combiners for 12VDC Cameras.
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or
moisture. This installation should be made by qualified service personnel and should conform to
all local codes.
Installation Instructions:
1. Set the input voltage selector switch located on the left side of the HubWayLD8D/LD16D unit (facing front panel)
for 115VAC or 230VAC operation (Fig. 1k, pg
2. Attach mounting brackets to HubWayLD unit for rack or wall mount installation (Figs. 6-7, pg. 8). Affix rubber pads
to H
ubWayLD for shelf installation (Fig. 8, pg. 8).
- 2 -HubWayLD Active Unit
. 4).
3. Secure the unit in a rack, mount unit to a wall or place unit on a shelf as desired (unit should be spaced at least
3” from any video monitors).
4. Set illuminated master power disconnect circuit breaker to the (OFF) position (F
ig. 5, pg. 7).
5. Plug the grounded AC line cord (included) into the IEC 320 connector of the HubWayLD8D/HubWayLD16D
unit (Fig. 1j, pg. 4). Insert the plug end of the line cord into a grounded AC receptacle.
6.
Set voltage output selector switch of each camera channel for 24VAC or 28VAC (Fig. 1d, pg. 4).
7.
Connect the BNC video outputs for HubWayLD8D/LD16D Channels 1 - 8 (Channels 1-16) to the
corresponding video inputs on the head end equipment (DVR) (Fig. 1f, pg. 4).
8.
Connect the RS422/RS485 output of the head end equipment (DVR) to the one (1) or both data input terminal
blocks of the HubWayLD8D or HubWayLD16D unit (polarity must be observed) (Fig. 1e, pg. 4). Note: The Data input terminals of the HubWayLD8D or HubWayLD16D must be wired in parallel for proper
operation.
When using fixed cameras disregard this step.
9. Connect Video Balun/Combiner at camera 1 to the HubWayLD8D or HubWayLD16D unit utilizing CAT-5 or higher
structured cable. Plug the RJ45 connector at one end of the structured cable into the RJ45 jack marked [Channel 1]
of the HubWayLD8D/LD16D (Fig. 1a, pg. 4). Plug the RJ45 connector at the opposite end of the structured
cab
le into the RJ45 jack of the Video Balun/Combiner located at camera 1.
• For 24VAC cameras use Altronix model HubWayAv Video Balun/Combiner (Figs. 2a, 2b, pg. 5).
•
For 12VDC cameras use Altronix model HubWayDv Video Balun/Combiner (Figs. 2c, 2d, pg. 5).
•
For non-isolated 12VDC cameras use Altronix model HubWayDvi Video Balun/Combiner (Figs. 2c, 2d, pg. 5).
Repeat steps 6-9 for each additional camera (Channels 2-8 or Channels 2-16).
Note: When a particular camera exceeds the maximum distance for power transmission, a local
e
xternal power source is required. Optionally, an Altronix HubSat4D Passive UTP Transceiver Hub with Integral
Camera Power may be utilized (Fig. 4a, pg. 6). The combined total cable distance must not exceed 3000 ft. for
video transmission between the HubWa
yLD8D/LD16D and each camera routed through the HubSat4D.
10. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 5, pg. 7) and measure the
output v
to insure proper operation and a
oltage at the power output of each Video Balun/Combiner (Figs. 2b, 2d, pg. 5) before powering each camera
wer outputs of the HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiners to the
power inputs of the cameras (Figs. 2a-2d, pg. 5). Polarity must be observed.
13.
Connect the terminals marked [+ DATA -- ] of the HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiners
to the data terminals of the cameras for PTZ control (Figs. 2a-2d, pg. 5). Polarity must be observed.
When using fixed cameras disregard this step.
14. Connect the BNC connectors of the HubW
ayAv, HubWayDv or HubWayDvi Video Balun/Combiners to the
BNC video outputs of the cameras (Figs. 2a-2d, pg. 5).
15.
Upon completion of wiring set illuminated master power disconnect circuit breaker to the RESET (ON) position
(Fig
. 5, pg. 7).
16. The power LEDs (Red) located on the front of the HubWayLD8CD/LD16CD will illuminate when AC power
is present (Fig. 1c, pg. 4).Note: If any of these LEDs are not illuminated either a voltage output selector switch is in the OFF position or the
PTC is tripped for that channel.
To reset the PTC:
1. Set the voltage output selector switch for that corresponding channel to the OFF position. Switch must remain
in the OFF position for appro
ximately 2 minutes in order for the PTC to reset.
2. Eliminate the trouble condition (short circuit or overload).
3. Set the voltage output selector switch for 24VAC or 28VAC (Fig. 1d, pg. 4).
17.
AC LEDs (Green) of the HubWayAv or DC LEDs (Red) of the HubWayDv/HubWayDvi Video Balun/Combiners
will illuminate indicating power is present at the cameras (Fig. 2b, 2d, pg. 5).
18. The video signal indicator LEDs (Red) located on the rear of the HubWayLD8CD/LD16CD will illuminate when
video signal is present (Fig. 1i, pg. 4). If any of these LEDs are not illuminated, no video signal is present for
that cor
responding channel.
19. Optimize the picture quality for all camera channels by adjusting the corresponding potentiometers
marked [Picture] (Fig. 1g, pg. 4).
20. Set gain for all camera channels adjusting the corresponding potentiometers marked [Gain] (Fig. 1h, pg. 4).
HubWayLD Active Unit- 3 -
1 2 3 4 CH 1-4 CH 5-8
28VAC
OFF
24VAC
+ DATA -
1-8
+ DATA -
9-16
5 6 7 8 9 10 11 12 CH 9-12
28VAC
OFF
24VAC
13 14 15 16 CH 13-16
AC POWER
16
PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAINPICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN
Video Balun/
Combiner
for non-isolated
12VDC cameras
Altronix
Model
Number
HubWayAv
HubWayAv, HubWayDv and HubWayDvi Video Balun/Combiners:
unit
from HubWay
Input Voltage
*24VAC/28VAC *24VAC/28VAC
to camera
Output Voltage
Camera Type
24VAC cameras
Power LED
Green
HubWayDv
HubWayDvi
*24VAC/28VAC 12VDC
*24VAC/28VAC 12VDC electronically isolated12VDC cameras without isolationRed
*Based on camera load and structured cable length.
Fig. 2
Fig. 2a
Fig. 2c
Fig. 2bFig. 2d
12VDC cameras
Red
HubWayAv passes AC voltage from pins 4, 5, 7, 8 to
ter
minals marked [AC Power] (Fig. 3, pg. 5).
HubW
ayDv/HubWayDvi converts AC voltage to DC
voltage from pins 4, 5, 7, 8 to terminals marked
[-- 12VDC +] (Fig. 3, pg. 5).
Fig. 3 - CAT-5 Structured Cable Wiring Color Codes and PIN Configurations
HubWayLD Active Unit- 5 -
115VAC
Input, 50/60Hz
Video
Power
Video
Data
Power
Video
Power
HubWayDv/Dvi
Video Balun
Combiner
CAT-5
CAT-5
CAT-5
Fixed
Camera
Fixed
Camera
HubWayAv
Video Balun
Combiner
D
ata
Video
Head End Equipment (DVR)
RS485
Video (Coax)
Four (4) Video
signals on a
single CAT-5
Data
(CAT-5)
Power
HubWayDv/Dvi
Video Balun
Combiner
Video
Data
PTZ
Camera
PTZ
Camera
Power
Video
Data
Power
HubWayAv
Video Balun
Combiner
HubWayAv
Video Balun
Combiner
Fixed
Camera
Fixed
Camera
Max.
video
3000 ft.
PTZ
Camera
Video
Power
HubWayDv/Dvi
Video Balun
Combiner
CAT-5
24VAC/28VAC
Camera Power
Provided
by HubSat4D
Video
Data
Power
Outdoor
NEMA
Rated
Power
Supply
Outdoor
PTZ
Camera
115VAC Input,
50/60Hz
HubWayAv or
HubWayDv/Dvi
Video Balun
Combiner
Monitor
R
ear
Front
1234CH 1-4CH 5-8
28VAC
OFF
24VAC
+ DATA -
1-8
5678
PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE
AC POWER
GAIN
87654321
Fig. 4
Typical Applications:
Fig. 4a - Optional hookup utilizing HubSat4D.
- 6 -HubWayLD Active Unit
1
.625"
8
.5"
.75"
19.125"
17.625"
(ON)
1
6
P
ICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE
A
C POWER
G
AIN
1
5 14 13 12 11 10 9 8 7 6 5 4 3 2 1
1 2 3 4 CH 1-4 CH 5-8
28VAC
OFF
24VAC
+ DATA --
1-8
+ DATA --
9-16
5 6 7 8 9 10 11 12 CH 9-12
28VAC
OFF
24VAC
13 14 15 16 CH 13-16
1U EIA 19” Rack Mount Chassis Mechanical Drawing & Dimensions:
1.625”H x 19.125”W x 8.5”D
REAR
TOP & BOTTOM
FRONT
Fig. 5
Illuminated master power disconnect circuit breaker:
•
OFF position Circuit breaker tripped – Switch not illuminated.
• RESET (ON) position – Switch illuminated.
The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the
presence of an insulated “DANGEROUS VOLTAGE” within the products enclosure that may be of sufficient
magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open enclosure. There
are no user ser
viceable parts inside. Refer servicing to qualified service personnel.
HubWayLD Active Unit- 7 -
Mounting Options:
B
A
C
B
A
C
A
B
Rack Mount Installation
1- Remove and discard factory installed screws from both sides of rack chassis (Fig. 6a).
2- Install mounting brackets (A) on the left and right side of rack chassis using the
four (4) flat head screws (B) (included) (Fig. 6b).
3-
Place unit into desired EIA 19” rack position and secure with mounting screws (not included) (Fig. 6c).
Fig. 6
Fig. 6a
Fig. 6b
Fig. 6c
TopTopTop
Front
F
ront
Left
Left
Remove
Wall Mount Installation
1- Install mounting brackets (A) on the left and right side of rack chassis using
four (4) flat head screws (B) (included) (Fig. 7a).
2- Place unit at desired location and secure with mounting screws
(not included) (Fig. 7b).
Caution: It is necessary to
make sure mounting screws
are securel
y fastened to a
beam when installing the
unit vertically.
F
ig. 7
Fig. 7a
Fig. 7b
Front Left
Dotted lines indicate studs
behind sheetr
ock.
Shelf Installation
1- Position and affix rubber pads (C) (included) at each
corner on the bottom of the unit (Fig. 8).
2-
Place unit in desired location.
Fig. 8
Left Side
Rubber Pad
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
website: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A.
IIHubWayLD8D/HubWayLD16D A14I
- 8 -HubWayLD Active Unit
Mounting Hardware (Included):
Two (2) mounting brackets
Six (6) flat head screws
for mounting brackets.
Four (4) rubber pads.