Altronix HubWay EX32 Installation Instructions

Video • Data
Active UTP Transceiver Hub
Installation Guide
Models Include:
HubWayEX16
- Sixteen (16) Camera Channels
HubWayEX32
- Thirty-two (32) Camera Channels
Rev. 011810
More than just power.
Overview:
Altronix HubWayEX16/EX32 Active UTP Transceiver Hub employs automatic gain control (AGC) to transmit UTP video, RS422/RS485 data over a single CAT-5 or higher structured cable. Units provide either 16 or 32 camera channels i
n a space saving 1U EIA 19” rack mount chassis which may be rack, wall or shelf mounted. Video transmission range is up to one mile max. per channel. Units are compatible with fixed or PTZ cameras. Each grouped camera channel pro­vides video transmission for up to four (4) cameras over a single CAT-5 or higher structured cable. This permits the installation of up to sixteen (16) cameras at remote locations over four (4) CAT-5 or higher structured cables or thirty-two (32) cameras at remote locations over eight (8) CAT-5 or higher structured cables.
HubWayEX Specifications:
HubWayEX16 Input:
• 115VAC 60Hz, 0.4 amp or 230VAC 50Hz, 0.2 amp.
Video:
• Sixteen (16) channels of video over twisted pair up to
a distance of 5000 ft. per channel.
• Sixteen (16) 75 ohm video outputs.
HubWayEX32 Input:
• 115VAC 60Hz, 0.4 amp or 230VAC 50Hz, 0.2 amp.
Video:
• Thirty-two (32) channels of video over twisted pair up to a distance of 5000 ft. per channel.
• Thirty-two (32) 75 ohm video outputs.
Specifications:
Data:
RS422/RS485 data inputs.
Visual Indicators:
• AC input power indicator.
• Video signal and power LED indicators.
Features:
• Automatic picture and g
• Automatic compensation for reverse polarity wiring (video).
• Illuminated master power disconnect circuit breaker with manual reset.
ain control.
Features (cont’d):
• IEC 320 - 3-wire grounded line cord (detachable).
• Unit can be rack, wall or shelf mounted.
• 1U rack mount chassis for use in standard EIA 19” rack.
Accessories:
• Optional transmission of up to four (4) video signals over a single CAT-5 or higher structured cable.
HubSat4D/Di or HubWayEXP allows
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This installation should be made by qualified service personnel and should conform to all local codes.
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the application.
Set the input v
1. for 115VAC or 230VAC operation
2. Attach mounting brackets to HubWayEX16/EX32 unit for rack or wall mount installation Affix rubber pads to HubWayEX16/EX32 for shelf installation
3. Secure the unit in a rack, mount unit to a wall or place unit on a shelf as desired (unit should be spaced at least
3” from any video monitors).
Set illuminated master po
4.
5. Plug the grounded AC line cord into the IEC 320 connector of the HubWayEX16/EX32. For US & Canada the plug end is a 3 prong type B plug used for standard 115VAC receptacles, as provided with unit North American 230VAC applications use the appropriate 3 prong plug that matches the local standard receptacle.
6. Connect the BNC video outputs for HubWayEX16/EX32 Channels 1-32 to the corresponding video inputs on the head end equipment (DVR) (Fig. 1c, pg. 3). Connect the RS422/RS485 output of the head end equipment (D
7.
locks of the HubW
b Note: The Data input terminals of the HubWayEX16/EX32 must be wired in parallel for proper operation. When using f Connect one (1) end of a CA
8. CH 13-16] of the HubWayEX16 or [CH 1-4, CH 5-8, CH 9-12, CH 13-16, CH 17-20, CH 21-24, CH 25-28, CH 29-32] of the HubWayEX32 into the corresponding RJ45 jack marked [CH 1-4, CH 5-8] HubWayEXP [VIDEO 1-4] of the
oltage selector s
yEX16/EX32 unit (polarity must be obser
a
ixed cameras disregard this step.
HubSat4D/Di
witch located on the left side of the HubWayEX16/EX32 unit (facing front panel)
(Fig. 1b, pg. 3).
(Figs. 6-7, pg. 8).
(Fig. 8, pg. 8).
wer disconnect circuit breaker to the (OFF) position
VR) to the one (1) or both data input ter ed)
v
(F
-5 or higher structured cable into the RJ45 jack marked [CH 1-4, CH 5-8, CH 9-12,
T
(Fig. 1d, pg. 3). Connect the opposite end of the CAT-5 or higher structured cable
. 5, pg. 6)
ig
(F
.
, pg
. 1f
ig
(Fig. 4, pg. 5) or
(F
ig
. 3)
. 5, pg. 7)
.
.
(Fig. 1g, pg. 3). For non
minal
- HubWayEX16/HubWayEX32 Active Hub Unit
2
-
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ACTIVE ACTIVE
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
16 15 14 13 12 11 10 9
32 31 30 29 28 27 26 25
8 7 6 5 4 3 2 1
24 23 22 21 20 19 18 17
CH 13 - 16
CH 29 - 32 CH 25 - 28
CH 9 - 12 CH 5 - 8
CH 21 - 24 CH 17 - 20
DATA
CH 1 - 4
AC POWER
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ACTIVE ACTIVE
8 7 6 5 4 3 2 1
CH 5 - 8
DATA
CH 1 - 4
AC POWER
16 15 14 13 12 11 10 9
CH 13 - 16 CH 9 - 12
EX
EX
Connector:
+ --
Data input
from
Head End
Equipment
(DVR).
115VAC 220VAC
1g - IEC 320
Grounded
line cord
included.
(switch is located on the left side of the unit).
1b - Input Voltage Switch: Selects 115VAC/230VAC
1f - Data: Removable
equipment (DVR) for PTZ control.
terminal blocks for RS422/
RS485 input from head end
CAT-5 or higher
transmission to PTZ’s.
structured cable to HubWayEXP for the data
1e - DATA 1-16, 17-32:
HubW
signal indicators.
1a - LED(s) 1-16: Video
Fig. 1
yEX16/HubW
a
yEXP a
CAT-5 or
le to HubW
uctured cab
1d - Channels 1-4, 5-8, 9-12. 13-16,
higher str
utilized for the video transmission.
17-20, 21-24, 25-28, 29-32:
ont r
F
Active Hub Unit
yEX32
a
Rear
ideo
VR).
V
1c - BNC
Connector:
outputs to head end
equipment (D
HubWayEX16 Front
HubWayEX16 Rear
-
3
-
Loading...