- UL Listed sixteen (16) Channel Active UTP Transceiver Hub with Integral Isolated Camera Power
Rev. 011810
More than just power.
TM
![](/html/a4/a49e/a49eba90265ffcbb6b5dce1048bd5d960f6ad1d25511bbbfaca437e4169a9da9/bg2.png)
Overview:
Altronix HubWayEX16SP Active UTP Transceiver Hub w/Integral Isolated Camera Power empl oys automatic gain control (AGC) to transmit UTP video, RS422/RS485 data and power o v er a single CAT-5 or higher structured cable. Units pro-
vide 16 camera channels in a space saving 1U EIA 19” rack mount chassis which may be rack, wall or shelf mounted. V ideo
transmission range is up to one (1) mile max. per channel. Units are compatible with AC and/or DC fixed or PTZ cameras
when utilizing Altronix HubWayAv, HubWayDv Video Balun/Combiners. In addition, the unit features individually selectable 24VAC or 28VAC PTC protected outputs with surge suppression. An optional HubSat4D/4Di Passive UTP T ranscei ver
Hub with Integral Camera Power can be used as a remote accessory module to transmit video from up to 4 cameras over a
single CAT-5 or higher structured cable back to the HubWayEX16SP. In addition, the HubSat4D/4Di provides power to
these cameras locally to eliminate the possibility of voltage drop associated with long cable runs.
Specifications:
Input:
• 115VAC 60Hz, 2.5 amp or 230VAC 50Hz, 1.5 amp.
Video:
• Sixteen (16) channels of video over twisted pair up to
a distance of 5000 ft. per channel.
• Sixteen (16) 75 ohm video outputs.
• Active balun combiners not required.
Data:
• RS422/RS485 data inputs.
Power:
• Unit provides up to 1 amp max. per channel.
• Individually selectable 24VAC or 28VAC isolated
power outputs with OFF position.
• Individual electronically isolated PTC outputs.
• PTCs are rated @ 1 amp per channel.
• Surge suppression.
Visual Indicators:
• AC input power indicator.
Visual Indicators (cont’d):
• Video signal and power LED indicators.
Features:
• Automatic picture and gain control.
• Automatic compensation for reverse polarity
wiring (video).
• Illuminated master power disconnect circuit breaker
with manual reset.
• IEC 320 - 3-wire grounded line cord (detachable).
• Unit can be rack, wall or shelf mounted.
• 1U rack mount chassis for use in standard EIA 19” rack.
Accessories:
• Video Balun/Combiners:
- HubWayAv - for use with 24VAC cameras.
- HubWayDv - for use with 12VDC cameras.
• Optional HubSat4D/Di allows transmission of up to
four (4) video signals over a single CAT-5 or higher
structured cable.
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture.
This installation should be made by qualified service personnel and should conform to all local codes.
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and
authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the application.
1. Set the input voltage selector switch located on the left side of the HubWayEX16SP unit (facing front panel)
for 115VAC or 230VAC operation (Fig. 1i, pg. 4).
2.
Attach mounting brackets to HubWayEX16SP unit for rack or wall mount installation (Figs. 7-8, pg. 8).
Affix r ubber pads to HubWayEX16SP for shelf installation (Fig. 9, pg. 8).
3.
Secure the unit in a rack, mount unit to a wall or place unit on a shelf as desired (unit should be spaced at least
3” from any video monitors).
4. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 6, pg. 7).
5.
Plug the grounded AC line cord into the IEC 320 connector of the HubWayEX16SP. For US & Canada the
plug end is a 3 prong type B plug used for standard 115VAC receptacles, as provided with unit (Fig. 1h, pg. 4). For
non Nor
6. Set voltage output selector switch of each camera channel for 24VAC or 28VAC (Fig. 1d, pg. 4).
7.
Connect the BNC video outputs for HubWayEX16SP Channels 1-16 to the
corresponding video inputs on the head end equipment (DVR) (Fig. 1f, pg. 4).
8.
Connect the RS422/RS485 output of the head end equipment (DVR) to the one (1) or both data input terminal
blocks of the HubWayEX16SP unit (polarity must be observed) (Fig
Note: The Data input terminals of the HubWayEX16SP must be wired in parallel for proper
operation. When using fixed cameras disregard this step.
9. Connect Video Balun/Combiner at camera 1 to the HubWayEX16SP unit utilizing CAT-5 or higher structured
cable. Plug the RJ45 connector at one end of the structured cable into the RJ45 jack marked [Channel 1] of the
th American 230VAC applications use the appropriate 3 prong plug that matches the local standard receptacle.
. 1e, pg. 4).
- 2- HubWayEX16SP Active Unit
![](/html/a4/a49e/a49eba90265ffcbb6b5dce1048bd5d960f6ad1d25511bbbfaca437e4169a9da9/bg3.png)
HubWayEX16SP (Fig. 1a, pg. 4). Plug the RJ45 connector at the opposite end of the structured cable into the
RJ45 jack of the Video Balun/Combiner located at camera 1.
• For 24VAC cameras use Altronix model HubWayAv Video Balun/Combiner (F
ig. 3a, pg. 5).
• For 12VDC cameras use Altronix model HubWayDv Video Balun/Combiner (Figs. 3b, pg. 5).
Repeat steps 6-9 for each additional camera (Channels 2-16 for HubWayEX16SP).
Note: When a particular camera exceeds the maximum distance for power transmission, a local
e
xternal power source is required. Optionally, an Altronix HubSat4D/Di Passive UTP Transceiver Hub with Integral
Camera Power may be utilized (Fig. 5, pg. 6).
The combined total cab
le distance must not exceed 5000 ft. for video transmission between the
HubWayEX16SP and each camera routed through the HubSat4D/4Di Remote Accessory Module
(refer to HubSat4D/Di installation instructions).
10.
Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 6, pg. 7) and measure
the output voltage at the power output of each Video Balun/Combiner (Figs. 3a, 3b, pg. 5) before powering each
camera to insure proper operation and avoid possible damage.
• HubWayAv - Ter minals marked [AC POWER] (Fig. 3a, pg. 5).
•
HubWayDv - Terminals marked [– 12VDC +] (Fig. 3b, pg. 5).
11. Set illuminated master power disconnect circuit breaker to the (OFF) position to make the f inal connections
(Fig. 6, pg. 7).
12.
Connect the power outputs of the HubWayAv or HubWayDv Video Balun/Combiners to the power inputs of the
cameras (Figs. 3a-3b, pg. 5). Polarity must be observed.
13.
Connect the terminals marked [+ DATA --] of the HubWayAv or HubWayDv Video Balun/Combiners to the data
terminals of the cameras for PTZ control (Figs. 2a-2d, pg. 5). Polarity must be observed.
When using fixed cameras disre
gard this step.
14. Connect the BNC connector of the HubWayAv or HubWayDv Video Balun/Combiners to the
BNC video outputs of the cameras (Figs. 3a-3b, pg. 5).
15.
Upon completion of wiring set illuminated master power disconnect circuit breaker to the RESET (ON) position
(Fig. 6, pg. 7).
16. The power LEDs (Red) located on the front of the HubWa
yEX16SP will illuminate when AC power
is present (Fig. 1c, pg. 4).
Note: If any of these LEDs are not illuminated either a voltage output selector s
witch is in the OFF position or the
PTC is tripped for that channel.
To reset the PTC:
1. Set the voltage output selector switch for that corresponding channel to the OFF position. Switch must remain
in the OFF position for approximately 2 minutes in order for the PTC to reset.
2. Eliminate the trouble condition (short circuit or overload).
3. Set the voltage output selector switch for 24VAC or 28VAC (Fig
. 1d, pg. 4).
17. AC LED (Green) of the HubWayAv or DC LED (Red) of the HubWayDv Video Balun/Combiners
will illuminate indicating power is present at the cameras (Fig. 3a, 3b, pg. 5).
18. The video signal indicator LEDs (Red) located on the rear of the HubWayEX16SP will illuminate when
video signal is present (Fig. 1g, pg. 4). If any of these LEDs are not illuminated, no video signal is present for
that cor
responding channel.
HubWayEX16SP Active Unit - 3 -