Passive UTP Transceiver Hub
with Integral Isolated Camera Power
Installation Guide
Models Include:
HubWay8DiHubWay16Di
- UL Listed eight (8) Channel Passive UTP- UL Listed sixteen (16) Channel Passive UTP
Transceiver Hub with Integral Isolated Camera PowerTransceiver Hub with Integral Isolated Camera Power
HubWay82DiHubWay162Di
- UL Listed eight (8) Channel Passive UTP- UL Listed sixteen (16) Channel Passive UTP
Transceiver Hub with Integral Isolated Camera PowerTransceiver Hub with Integral Isolated Camera Power
- Includes eight (8) UL Listed Accessory - Includes sixteen (16) UL Listed Accessory
HubWayAv Video Balun/CombinersHubWayAv Video Balun/Combiners
HubWay83DiHubWay163Di
- UL Listed eight (8) Channel Passive UTP- UL Listed sixteen (16) Channel Passive UTP
Transceiver Hub with Integral Isolated Camera PowerTransceiver Hub with Integral Isolated Camera Power
- Includes eight (8) UL Listed Accessory - Includes sixteen (16) UL Listed Accessory
HubWayDv Video Balun/CombinersHubWayDv Video Balun/Combiners
Rev. 032108
More than just power.
TM
Page 2
Overview:
Altronix HubWay8Di/16Di Passive UTP Transceiver Hub w/Integral Isolated Camera Power transmits UTP video,
RS422/RS485 data and power over a single CAT-5 or higher structured cable. Unit provides 8 or 16 camera channels in a
space saving 1U EIA 19” rack mount chassis which may be rack, wall or shelf mounted. Video transmission range is up to
750 ft. max. per channel. Units are compatible with AC and/or DC fixed or PTZ cameras when utilizing Altronix
HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiners. In addition, the unit features individually selectable
24VAC or 28VAC electronically isolated PTC protected outputs with surge suppression. An optional HubSat4D Passive
UTP Transceiver Hub with Integral Camera Power can be used as an accessory module to transmit video from up to 4
cameras over a single CAT-5 or higher structured cable back to the HubWay8Di/16Di. In addition, the HubSat4D provides
power to these cameras locally to eliminate the possibility of voltage drop associated with long cable runs.
HubWay Specifications:
HubWay8Di/82Di/83Di
Input:
• 115VAC 60Hz, 2.5 amp or
230VAC 50/60Hz, 1.5 amp.
Video:
• Eight (8) channels of video over twisted pair up to
a distance of 750 ft. per channel.
• Eight (8) 75 ohm video outputs.
Power:
• Unit provides up to 1 amp max. per channel not to
exceed a total of 8 amp maximum current.
Common Specifications:
Agency Listings:
• UL Listed for Commercial CCTV
Equipment (UL 2044).
CUL Listed - CSA Standard C22.2 No.1-04, Audio,
Video and Similar Equipment.
Data:
• RS422/RS485 data inputs.
Power:
• Individually selectable 24VAC or 28VAC power outputs
• Sixteen (16) channels of video over twisted pair up to
a distance of 750 ft. per channel.
• Sixteen (16) 75 ohm video outputs.
Power:
• Unit provides up to 1 amp max. per channel not to
exceed a total of 16 amp maximum current.
Features:
• Illuminated master power disconnect circuit breaker
with manual reset.
• IEC 320 - 3-wire grounded line cord (detachable).
• Unit can be rack, wall or shelf mounted.
• 1U rack mount chassis for use in standard EIA 19” rack.
Accessories:
• Video Balun/Combiners:
- HubWayAv - for use with 24VAC cameras.
- HubWayDv - for use with 12VDC cameras.
- HubWayDvi - for use with non-isolated 12VDC cameras.
• Optional HubSat4D allows transmission of up to
four (4) video signals over a single CAT-5 or higher
structured cable.
Additional Models:
ay82Di
HubW
• HubWay8Di with eight (8) UL Listed Accessory
HubWayAv Video Balun/Combiners for 24VAC Cameras.
HubWay83Di
• HubWay8Di with eight (8) UL Listed Accessory
HubWayDv Video Balun/Combiners for 12VDC Cameras.
HubWay162Di
• HubWay16Di with sixteen (16) UL Listed Accessory
HubWayAv Video Balun/Combiners for 24VAC Cameras.
HubWay163Di
• HubWay16Di with sixteen (16) UL Listed Accessory
HubWayDvVideo Balun/Combiners for 12VDC Cameras.
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or
moisture. This installation should be made by qualified service personnel and should conform to
all local codes.
- 2 -HubWay Passive Unit
Page 3
Installation Instructions:
1. Set the input voltage selector switch located on the left side of the HubWay8Di/16Di unit (facing front panel)
for 115VAC or 230VAC operation (Fig. 1h, pg. 4).
2
. Attach mounting brackets to HubWay unit for rack or wall mount installation (Figs. 6-7, pg. 8). Affix rubber pads
to H
ubWay for shelf installation (Fig. 8, pg. 8).
3.
Secure the unit in a rack, mount unit to a wall or place unit on a shelf as desired (unit should be spaced at least
3” from any video monitors).
4. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 5, pg. 7).
5.
Plug the grounded AC line cord (included) into the IEC 320 connector of the HubWay8Di/HubWay16Di
unit (Fig. 1g, pg. 4). Insert the plug end of the line cord into a grounded AC receptacle.
6.
Set voltage output selector switch of each camera channel for 24VAC or 28VAC (Fig. 1d, pg. 4).
7.
Connect the BNC video outputs for HubWay8Di/16Di Channels 1 - 8 (Channels 1-16) to the
corresponding video inputs on the head end equipment (DVR) (Fig. 1f, pg. 4).
8.
Connect the RS422/RS485 output of the head end equipment (DVR) to the one (1) or both data input terminal
blocks of the HubWay8Di/16Di unit (polarity must be observed) (Fig. 1e, pg. 4). Note: The Data input terminals of the HubWay8Di/16Di must be wired in parallel for proper operation.
When using f
9. Connect Video Balun/Combiner at camera 1 to the HubWay8Di/16Di unit utilizing CAT-5 or higher
structured cable. Plug the RJ45 connector at one end of the structured cable into the RJ45 jack marked [Channel 1]
of the HubWay8Di/16Di (Fig. 1a, pg. 4). Plug the RJ45 connector at the opposite end of the structured
cab
le into the RJ45 jack of the Video Balun/Combiner located at camera 1.
• For 24VAC cameras use Altronix model HubWayAv Video Balun/Combiner (Figs. 2a, 2b, pg. 5).
•
For 12VDC cameras use Altronix model HubWayDv Video Balun/Combiner (Figs. 2c, 2d, pg. 5).
• F
or non-isolated 12VDC cameras use Altronix model HubWayDvi Video Balun/Combiner (Figs. 2c, 2d, pg
Repeat steps 6-9 for each additional camera (Channels 2-8 or Channels 2-16).
Note: When a particular camera e
external power source is required. Optionally, an Altronix HubSat4D Passive UTP Transceiver Hub with Integral
Camera Power may be utilized (Fig. 4a, pg. 6). The combined total cable distance must not exceed 750 ft. for
video transmission between the HubWa
10. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 5, pg. 7) and measure the
output v
to insure proper operation and avoid possible damage.
11. Set illuminated master power disconnect circuit breaker to the (OFF) position to make the final
connections (Fig. 5, pg. 7).
12. Connect the power outputs of the HubW
inputs of the cameras (Figs. 2a-2d, pg. 5). Polarity must be observed.
13.
Connect the terminals marked [+ DATA -- ] of the HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiners
to the data terminals of the cameras for PTZ control (Figs. 2a-2d, pg. 5). Polarity must be observe
When using fixed cameras disregard this step.
14.
Connect the BNC connector of the HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiners to the
BNC video outputs of the cameras (Figs. 2a-2d, pg. 5).
15.
Upon completion of wiring set illuminated master power disconnect circuit breaker to the RESET (ON) position
(Fig. 5, pg. 7).
16. The power LEDs (Red) located on the front of the HubWay8Di/16Di will illuminate w
is present (Fig. 1c, pg. 4).Note: If any of these LEDs are not illuminated either a voltage output selector switch is in the OFF position or the
PTC is tripped for that channel.
T
o reset the PTC:
1. Set the voltage output selector switch for that corresponding channel to the OFF position. Switch must remain
in the OFF position for approximately 2 minutes in order for the PTC to reset.
2. Eliminate the trouble condition (short circuit or overload).
3. Set the voltage output selector switch for 24VAC or 28VAC (Fig
17. AC LEDs (Green) of the HubWayAv or DC LEDs (Red) of the HubWayDv/HubWayDvi Video Balun/Combiners
will illuminate indicating power is present at the cameras (Fig. 2b, 2d, pg. 5).
ixed cameras disregard this step.
. 5).
xceeds the maximum distance for power transmission, a local
y8Di/16Di and each camera routed through the HubSat4D.
oltage at the power output of each Video Balun/Combiner (Figs. 2b, 2d, pg. 5) before powering each camera
ayAv, HubWayDv or HubWayDvi Video Balun/Combiners to the power
Video Balun/
Combiner
for non-isolated
12VDC cameras
Altronix
Model
Number
HubWayAv
HubWayAv, HubWayDv and HubWayDvi Video Balun/Combiners:
unit
from HubWay
Input Voltage
*24VAC/28VAC *24VAC/28VAC
to camera
Output Voltage
Camera Type
24VAC cameras
Power LED
Green
HubWayDv
HubWayDvi
*24VAC/28VAC 12VDC
*24VAC/28VAC 12VDC electronically isolated 12VDC cameras without isolationRed
*Based on camera load and structured cable length.
Fig. 2
Fig. 2a
Fig. 2c
Fig. 2bFig. 2d
12VDC cameras
Red
HubWayAv passes AC voltage from pins 4, 5, 7, 8 to
terminals marked [AC Power] (Fig. 3, pg. 5).
HubW
ayDv/HubWayDvi converts AC voltage to DC
voltage from pins 4, 5, 7, 8 to terminals marked
[-- 12VDC +] (Fig. 3, pg. 5).
Fig. 3 - CAT-5 Structured Cable Wiring Color Codes and PIN Configurations
HubWay Passiive Unit- 5 -
Page 6
115VAC
Input, 50/60Hz
Video
Power
Video
Data
Power
Video
Power
HubWayDv/Dvi
Video Balun
Combiner
CAT-5
CAT-5
CAT-5
HubWayAv
Video Balun
Combiner
PTZ
Camera
PTZ
Camera
PTZ
Camera
Data
Video
Head End Equipment (DVR)
R
S485
Video (Coax)
Four (4) Video
signals on a
single CAT-5
D
ata
(CAT-5)
Power
Fixed
Camera
Fixed
Camera
Fixed
Camera
Fixed
Camera
HubWayDv/Dvi
Video Balun
Combiner
Video
Data
Power
Video
Data
Power
HubWayAv
Video Balun
Combiner
HubWayAv
Video Balun
Combiner
Max.
video
750 ft.
V
ideo
Power
HubWayDv/Dvi
Video Balun
Combiner
CAT-5
24VAC/28VAC
Camera Power
Provided
by HubSat4D
Video
Data
Power
Outdoor
NEMA
Rated
Power
Supply
Outdoor
PTZ
Camera
115VAC Input,
50/60Hz
HubWayAv or
HubWayDv/Dvi
Video Balun
Combiner
M
onitor
Rear
Front
1234CH 1-4CH 5-8
28VAC
O
FF
24VAC
+ DATA -
1-8
5678
A
C POWER
87654321
Fig. 4
Typical Applications:
- 6 -HubWay Passive Unit
Fig. 4a - Optional hookup utilizing HubSat4D.
Page 7
1.625"
8.5"
.75"
19.125"
17.625"
(ON)
1
6
AC POWER
1
5 14 13 12 11 10 9 8 7 6 5 4 3 2 1
1
2 3 4 CH 1-4 CH 5-8
28VAC
O
FF
24VAC
+ DATA --
1-8
+
DATA --
9
-16
5
6 7 8 9 10 11 12 CH 9-12
28VAC
O
FF
24VAC
1
3 14 15 16 CH 13-16
1U EIA 19” Rack Mount Chassis Mechanical Drawing & Dimensions:
1.625”H x 19.125”W x 8.5”D
REAR
TOP & BOTTOM
FRONT
Fig. 5
Illuminated master power disconnect circuit breaker:
•
OFF position Circuit breaker tripped – Switch not illuminated.
• RESET (ON) position – Switch illuminated.
The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the
presence of an insulated “DANGEROUS VOLTAGE” within the products enclosure that may be of sufficient
magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open enclosure. There
are no user ser
viceable parts inside. Refer servicing to qualified service personnel.
HubWay Passiive Unit- 7 -
Page 8
Mounting Options:
B
A
C
B
A
C
A
B
Rack Mount Installation
1- Remove and discard factory installed screws from both sides of rack chassis (Fig. 6a).
2- Install mounting brackets (A) on the left and right side of rack chassis using the
four (4) flat head screws (B) (included) (Fig. 6b).
3-
Place unit into desired EIA 19” rack position and secure with mounting screws (not included) (Fig. 6c).
Fig. 6
Fig. 6a
Fig. 6b
Fig. 6c
TopTopTop
Front
F
ront
Left
Left
Remove
Wall Mount Installation
1- Install mounting brackets (A) on the left and right side of rack chassis using
four (4) flat head screws (B) (included) (Fig. 7a).
2- Place unit at desired location and secure with mounting screws
(not included) (Fig. 7b).
Caution: It is necessary to
make sure mounting screws
are securel
y fastened to a
beam when installing the
unit vertically.
F
ig. 7
Fig. 7a
Fig. 7b
Front Left
Dotted lines indicate studs
behind sheetr
ock.
Shelf Installation
1- Position and affix rubber pads (C) (included) at each
corner on the bottom of the unit (Fig. 8).
2-
Place unit in desired location.
Fig. 8
Left Side
Rubber Pad
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
website: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A.
IIHubWay8Di/HubWay16DiA14I
- 8 -HubWay Passive Unit
Mounting Hardware (Included):
Two (2) mounting brackets
Six (6) flat head screws
for mounting brackets.
Four (4) rubber pads.
MEMBER
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.