Altronix HubSat4Di Specsheet

Video • Data • Power
Passive UTP Transceiver Hub with Integral Isolated Camera Power
Installation Guide
Models Include:
HubSat4Di
- Four (4) Camera Channels
HubSat42Di
- HubSat4Di w/four (4) HubWayAv Video Balun/Combiners for 24VAC Cameras
HubSat43Di
Overview:
Altronix HubSat4Di Passive UTP Transceiver Hub w/Integral Isolated Camera Power transmits UTP video, RS422/RS485 data and power over a single CAT-5 or higher structured cable. Unit provides 4 camera channels in a wall mount enclo­sure. Video transmission range is up to 750 ft. max. per channel. Units are compatible with AC and/or DC fixed or PTZ cameras when utilizing Altronix HubWayAv or HubWayDv Video Balun/Combiners. In addition, the unit features individ­ually selectable 24VAC or 28VAC electronically isolated fuse protected outputs with surge suppression. Optionally, the HubSat4Di can be used as an accessory module to transmit video from up to 4 cameras over a single CAT-5 or higher structured cable back to the HubWay, HubWayLD or HubWayLDH Passive and Active UTP Transceiver Hubs. In addition, the HubSat4Di provides power to these cameras locally to eliminate the possibility of voltage drop associated with long cable runs.
Specifications:
Input:
• 115VAC 50/60Hz, 1.25 amp.
• Primary in-line fuse is rated @ 3.5A/250V.
Video:
• Four (4) channels of quality video over twisted pair up to a distance of 750 ft. per channel.
• Four (4) 75 ohm video outputs.
Data:
RS422/RS485 data input.
Power:
• Individually selectable 24VAC or 28VAC power outputs with OFF position.
• Unit provides up to 1 amp max. per channel not to exceed a total of 4 amp maximum current.
Power (cont.):
• Individual electronically isolated outputs.
• PTC protected outputs are rated @ 1 amp per channel.
• Surge suppression.
Visual Indicators:
• Four (4) power LED indicators.
Enclosure Dimensions:
8.5”H x 7.5”W x 3.5”D
Optional Accessories:
• Video Balun/Combiners:
- HubWayAv - for use with 24VAC cameras.
- HubWayDv - for use with 12VDC cameras.
Additional Models: HubSat42Di
• HubSat4Di w/four (4) HubWayAv Video Balun/
Combiners for 24VAC Cameras.
HubSat43Di
• HubSat4Di w/four (4) HubWayDv Video Balun/ Combiners for 12VDC Cameras.
Installation Instructions:
HubSat4Di Passive UTP Transceiver Hub with Integral Isolated Camera Power.
1. Mount unit in desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure. Install tw upper keyholes over the two upper screws, level and secure. Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the two fasteners. Place the enclosure’s upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 8). Secure green wire lead to earth ground.
2.
Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 4a, pg. 6).
3.
Connect 115VAC 50/60Hz to the black and white flying leads of open frame transformer. Secure ground wire (Green) to earth ground (Fig. 5, pg will illuminate when AC power is present (Fig. 1e, pg. 4)
4. Select 24VAC or 28VAC power output for each of the Channels 1-4 on HubSat4Di (Fig. 4, pg. 6) with the corresponding
output v
5.
Connect the BNC video outputs marked [Video 1-4] on HubSat4Di to the corresponding video inputs on the head end equipment (DVR) (Fig. 1a, pg. 4).
6. Connect terminals marked [+ Data --- ] on HubSat4Di (polarity must be obser
head end equipment (DVR) (Fig. 1f, pg. 4). When using fixed cameras disregard this step.
7.
Plug the RJ45 connector at one end of the CAT-5 or higher structured cable into the RJ45 jack marked [PVD1] on HubSat4Di (Fig cable into the RJ45 jack of the Video Balun/Combiner to be installed at camera 1.
For 24VAC cameras use Altronix model HubWayAv Video Balun/Combiner (Figs. 2a, 2b, pg. 6).
For 12VDC cameras use Altronix model HubWayDv Video Balun/Combiner (Figs. 2c, 2d, pg. 6).
oltage switches. Select OFF position when servicing or installing individual cameras (Fig. 1d, pg. 4).
For non-isolated 12VDC cameras use Altronix model HubWayDvi Video Balun/Combiner (Figs. 2c, 2d, pg. 6).
o upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s
. 7). The power LEDs (Green) for Channels 1-4 of the HubSat4Di
ved) to the RS422/RS485 output of the
. 1i, pg. 4). Plug the RJ45 connector at the opposite end of the CAT-5 or higher structured
- 2 - HubSat4Di
The total cable distance must not exceed 750 ft. for video transmission between the HubSat4Di and each camera. Repeat this step for all other camera channels [PVD2-4].
8. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (F
LEDs (Green) of the HubSat will illuminate when AC power is present (F
ig. 1e, pg. 4) and HubWayAv, HubWayDv
ig. 4a, pg. 6) power
or HubWayDvi Video Balun/Combiner LEDs will illuminate indicating power is present (Fig. 2b, 2d, pg. 6).
9. Measure the output voltage at each Video Balun/Combiner (Figs. 2b, 2d, pg. 6) before making connections to
each camera to insure proper operation and a
void possible damage.
10. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 4a, pg. 6).
1
1. Connect power outputs of HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiners to power inputs of cameras (Figs. 2a-2d, pg. 6). Polarity must be observed.
HubWayAv - Terminals marked [AC POWER] (Figs. 2a, 2b, pg. 6).
HubWayDv/HubWayDvi - Terminals marked [– 12VDC +] (Figs. 2c, 2d, pg. 6).
1
2. Connect the terminals marked [+ DATA --] of HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiners to data input terminals of cameras for PTZ control (Figs. 2b-2d, pg. 6). Polarity must be observed. When using fixed cameras disregard this step.
1
3. Connect the BNC connector of HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiners to the BNC video outputs of cameras (Figs. 2b-2d, pg. 6).
1
4. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 4a, pg. 6).
15. The power LEDs (Green) of the HubSat4Di will illuminate when AC power is present (Fig. 1e, pg. 4). Note: If any of the power LEDs are not illuminated the cause may be due to the following: a.
AC mains fail. b. Illuminated master power disconnect circuit breaker is tripped. c. Primary in-line fuse is blown.
Note: Replace fuse with same type and rating:
Primary In-line Fuse
Primary in-line fuse is rated @ 3.5A/250V (Fig. 4b, pg. 6). d.
An individual power output voltage switch is set to the OFF position (Fig. 1d, pg. 4). e.
A PTC is tripped due to a short circuit or overload condition for one or more channels/power outputs.
To reset the PTC:
1. Set the voltage output selector switch for that corresponding channel to the OFF position. Switch must remain in the OFF position for approximately 2 minutes in order for the PTC to reset (Fig. 1d, pg. 4).
2. Eliminate the troub
le condition (short circuit or overload).
3. Set the voltage output selector switch for either 24VAC or 28VAC (Fig. 1d, pg. 4).
HubSat4Di for use as a Remote Accessory Module with HubWay/HubWa
yLD/HubWayLDH UTP Transceiver Hubs.
After completing steps 1-4 of Installation Instructions HubSat4Di Passive UTP Transceiver Hub with Integral Isolated Camera Po
wer proceed with the following.
1. For fixed cameras run a single CAT-5 cable between HubSat4Di and HubWay, HubWayLD or HubWayLDH to allow video transmission of up to four (4) cameras. For PTZs run two (2) CAT-5 cables between HubSat4Di and HubWay, HubWayLD or HubWayLDH (Fig
. 6, pg. 7).
a. Connect one (1) of the CAT-5 cables to the RJ45 jack marked [Video 1-4] on HubSat4Di. Connect the
opposite end of this CAT-5 cable into the RJ45 jack marked [CH 1-4] of HubWay, HubWayLD or HubWayLDH unit (Fig. 6, pg. 7).
b
. For data (PTZ) connect the second CAT-5 cable to the RJ45 jack marked [Data 1-4] on HubSat4Di. Connect
the opposite end of this CAT-5 cable into any unused RJ45 jack marked [1-16] of HubWay, HubWayLD or
HubWayLDH unit (Fig. 6, pg. 7). Note: Data inputs of HubWay, HubWayLD or HubWayLDH units must be wired in parallel for proper operation. When using f
ixed cameras disregard this step.
2. Plug the RJ45 connector at one end of the CAT-5 or higher structured cable into the RJ45 jack marked [PVD1] on HubSat4Di (Fig. 1i, pg. 4). Plug the RJ45 connector at the opposite end of the CAT-5 or higher structured cab
le into the RJ45 jack of the Video Balun/Combiner to be installed at camera 1.
For 24VAC cameras use Altronix model HubWayAv Video Balun/Combiner (Figs. 2a, 2b, pg. 6).
For 12VDC cameras use Altronix model HubWayDv Video Balun/Combiner (Figs. 2c, 2d, pg. 6).
For non-isolated 12VDC cameras use Altronix model HubWayDvi Video Balun/Combiner (Figs. 2c, 2d, pg. 6). The total cable distance must not exceed 750 ft. for video transmission between the HubSat4Di and each camera. Repeat this step for all other camera channels [PVD2-4].
HubSat4Di - 3 -
3. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 4a, pg. 6) power
PVD1
V
IDEO1 VIDEO2 VIDEO3 VIDEO4
PVD2 PVD3 PVD4
+ DATA -
DATA 1-4 VIDEO 1-4
28VAC
2
4VAC
28VAC
2
4VAC
28VAC
2
4VAC
28VAC
2
4VAC
OFF
OFF
OFF
OFF
A
UX1 AUX2
A
UX3 AUX4
LEDs (Green) of the HubSat4Di will illuminate when AC power is present (F or HubWayDvi Video Balun/Combiner LEDs will illuminate indicating power is present (F
4.
Measure the output voltage at each Video Balun/Combiner (Figs. 2b, 2d, pg. 6) before making connections to
ig. 1e, pg. 4) and HubWayAv, HubWayDv
ig. 2b, 2d, pg. 6).
each camera to insure proper operation and avoid possible damage.
5. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 4a, pg. 6). 6
. Connect power outputs of HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiners to power inputs
of cameras (Figs. 2a-2d, pg. 6). Polarity must be observed.
HubWayAv - Terminals marked [AC POWER] (Figs. 2a, 2b, pg. 6).
HubWayDv/HubWayDvi - Terminals marked [– 12VDC +] (Figs. 2c, 2d, pg. 6).
7
. Connect the terminals marked [+ DATA -- ] of HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiners
to data input terminals of cameras for PTZ control (Figs. 2b-2d, pg. 6). Polarity must be observed. When using fixed cameras disregard this step.
8
. Connect the BNC connector of HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiners to the
BNC video outputs of cameras (Figs. 2b-2d, pg. 6).
9
. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 4a, pg. 6).
F
ig. 1 - HubSat4Di Circuit Board
1c - Power Terminals: 24VAC/28VAC power outputs.
1b - Output
PTCs: Protects each output.
1d - Output Voltage Switches:
Selects 24V
AC/28VAC/OFF
for each output.
1a - BNC Connector: Video
in from remote camera video out to D
VR.
1i - Channels 1-4:
CAT-5 or higher structured cable to cameras.
1h - Data: CAT-5 or higher structured cable to data port on HubWay8/16, HubWayLD8/16, HubWayLDH8/16 or head end equipment (DVR).
1e - LED(s) 1-4:
Power output indicators.
1f - Data:
RS422/RS485 input from head end equipment (D
VR) for PTZ
control.
1g - Channels 1-4: Single CAT-5 or higher structured cable out to HubWay8/16, HubWayLD8/16, HubWayLDH8/16 enables transmission of up to four (4) video signals.
- 4 - HubSat4Di
Loading...