Altronix HubSat 4D Installation Instructions

Video • Data • Power
Passive UTP Transceiver Hub with Integral Camera Power
Installation Guide
Models Include:
HubSat4D
- Four (4) Camera Channels
HubSat42D
- HubSat4D w/four (4) HubWayAv Video Balun/Combiners for 24VAC Cameras
HubSat43D
Rev. 052708
More than just power.
TM
Overview:
Altronix HubSat4D Passive UTP Transceiver Hub w/Integral Camera Power transmits UTP video, RS422/RS485 data and power over a single CAT-5 or higher structured cable. Unit provides 4 camera channels in a wall mount enclosure. Video transmission range is up to 750 ft. max. per channel. Units are compatible with AC and/or DC fixed or PTZ cameras when utilizing Altronix HubWayAv or HubWayDv Video Balun/Combiners. In addition, the unit features individually selectable 24VAC or 28VAC PTC protected outputs with surge suppression. Optionally, the HubSat4D can be used as an accessory module to transmit video from up to 4 cameras over a single CAT-5 or higher structured cable back to the HubWay, HubWayLD or HubWayLDH Passive and Active UTP Transceiver Hubs. In addition, the HubSat4D provides power to these cameras locally to eliminate the possibility of voltage drop associated with long cable runs.
Specifications:
Input:
• 115VAC 50/60Hz, .9 amp.
• Primary in-line fuse is rated @ 3.5A/250V.
Video:
• Four (4) channels of quality video over twisted pair up to a distance of 750 ft. per channel.
• Four (4) 75 ohm video outputs.
Data:
RS422/RS485 data input.
Power:
• Individually selectable 24VAC or 28VAC power outputs with OFF position.
• PTC protected outputs.
• PTCs are rated @ 1 amp per channel.
Power (cont.):
• Unit provides up to 1 amp max. per channel not to exceed a total of 4 amp maximum current.
• Surge suppression.
Visual Indicators:
• Four (4) power LED indicators.
Enclosure Dimensions:
8.5”H x 7.5”W x 3.5”D
Optional Accessories:
• Video Balun/Combiners:
- HubWayAv - for use with 24VAC cameras.
- HubWayDv - for use with 12VDC cameras.
Additional Models: HubSat42D
• HubSat4D w/four (4) HubWayAv Video Balun/ Combiners for 24VAC Cameras.
HubSat43D
• HubSat4D w/four (4) HubWayDv Video Balun/ Combiners for 12VDC Cameras.
Installation Instructions:
HubSat4D Passive UTP Transceiver Hub with Integral Camera Power.
1. Mount unit in desired location. Mark and predrill holes in the w enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two upper screws, level and secure. Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the two fasteners. Place the enclosure’s upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 8). Secure green wire lead to earth ground.
2. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 4a, pg. 6).
3.
Connect 115VAC 50/60Hz to the black and white flying leads of open frame transformer. Secure ground wire (Green) to earth ground (Fig. 5, pg. 7). The power LEDs (Green) for Channels 1-4 of the HubSat4D will illuminate when
4. Select 24VAC or 28VAC power output for Channels 1-4 with the corresponding voltage adjustment switches (Fig. 1d, pg. 4).
5. Connect the BNC video outputs for HubSat4D Channels 1 - 4 to the corresponding video inputs
on the head end equipment (D
6. Connect the RS422/RS485 output of the head end equipment (DVR) to the data ter
of the HubSat4D unit (polarity must be observed) (Fig. 1f, pg. 4). Note: The Data input terminals of the HubSat4D must be wired in parallel for proper operation. When using f
ixed cameras disregard this step.
AC power is present (Fig
VR) (Fig. 1a, pg. 4).
. 1e, pg. 4)
all to line up with the top two keyholes in the
minals marked [+ Data ---]
- 2 - HubSat4D
7. Connect Video Balun/Combiner at camera 1 to the HubSat4D unit utilizing CAT-5 or higher structured cable.
Plug the RJ45 connector at one end of a structured cable into the RJ45 jack marked [PVD1] of the HubSat4D (F
ig. 1i, pg. 4). Plug the RJ45 connector at the opposite end of the structured cable into the
RJ45 jack of the Video Balun/Combiner located at camera 1.
• For 24VAC cameras use Altronix model HubWayAv Video Balun/Combiner (Figs. 2a, 2b, pg. 6).
For 12VDC cameras use Altronix model HubWayDv Video Balun/Combiner (Figs. 2c, 2d, pg. 6).
A
C LED (Green) of the HubWayAv or DC LED (Red) of the HubWayDv Video Balun/Combiners will illuminate indicating power is present at the cameras (Fig. 2b, 2d, pg. 6). The total cable distance must not exceed 750 ft. for video transmission between the HubSat4D and each camera. Repeat this step for each additional camera [PVD2-4].
8.
Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 4a, pg. 6) and measure the output v po
wering each camera to insure proper operation and avoid possible damage.
oltage at the power output of each Video Balun/Combiner (Figs. 2b, 2d, pg. 6) before
• HubWayAv - Terminals marked [AC POWER] (Figs. 2a, 2b, pg. 6).
HubWayDv - Terminals marked [– 12VDC +] (Figs. 2c, 2d, pg. 6).
9.
Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 4a, pg. 6).
10.
Connect the power outputs of the HubWayAv or HubWayDv Video Balun/Combiners to the power inputs of the cameras (Figs. 2a-2d, pg. 6). Polarity must be observed.
11.
Connect the terminals marked [+ DATA -- ] of the HubWayAv or HubWayDv Video Balun/Combiners to the data terminals of the cameras for PTZ control (Figs. 2b-2d, pg. 6). Polarity must be observed. When using f ixed cameras disre
gard this step.
12. Connect the BNC connector of the HubWayAv or HubWayDv Video Balun/Combiners to the BNC video outputs of the cameras (Figs. 2b-2d, pg. 6).
13. Set illuminated master pow
er disconnect circuit breaker to the RESET (ON) position (Fig. 4a, pg
. 6).
14. The power LEDs (Green) or Channels 1-4 of the HubSat4D will illuminate when AC power is present
(Fig. 1e, pg. 4). If any of these LEDs are off, a loss of AC power output may be due to a tripped PTC caused b
y a short circuit or overload condition. If all of the LEDs are OFF there may be a complete loss of supply power to the HubSat4D unit or the illuminated master power disconnect circuit breaker is in the OFF position or the primary in-line fuse is blown.*
To restore the power output for HubSat4D:
1- Switch cor
responding output voltage switch to the OFF position (Fig. 1d, pg. 4). 2- Eliminate the trouble condition. 3- Allow 1 minute for PTC to cool off. 4- Switch output voltage switch to the 24VAC or 28VAC position as desired (Fig. 1d, pg. 4).
*Note: Replace fuse with same type and r
Primary in-line fuse is rated @ 3.5A/250V (Fig. 4b, pg. 6).
HubSat4D for use as a Remote
Accessory Module with HubWay/HubWayLD/HubWayLDH UTP Transceiver Hubs.
ating:
Primary In-line Fuse
1. Mount unit in desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure. Install tw
o upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two upper screws, level and secure. Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the two fasteners. Place the enclosure’s upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 8). Secure g
2. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 4a, pg
reen wire lead to earth ground.
. 6).
3. Connect 115VAC 50/60Hz to the black and white flying leads of open frame transformer. Secure ground wire (Green) to earth ground (Fig. 6, pg. 7). The power LEDs (Green) for Channels 1-4 of the HubSat4D will illuminate w
4. Select 24V
hen AC power is present (Fig. 1e, pg. 4).
AC or 28VAC power output for Channels 1-4 with the corresponding voltage adjustment switches
(Fig. 1d, pg. 4).
5.
Video connection between HubSat4D and HubWay/HubWayLD/HubWayLDH: Plug the RJ45 connector at one end of a structured cable into the RJ45 jack marked [Video 1-4] of the HubSat4D (Fig. 1g, pg. 4). Plug the RJ45 connector at the opposite end of the structured cab
le into the RJ45 jack marked [Channels 1-4,
Channels 5-8, Channels 9-12, Channels 13-16] of the HubWay/HubWayLD/HubWayLDH (Fig. 6, pg. 7).
HubSat4D - 3 -
6. Data connection between HubSat4D and HubWay/HubWayLD/HubWayLDH UTP Transceiver Hubs:
PVD1
VIDEO1 VIDEO2 VIDEO3 VIDEO4
PVD2 PVD3 PVD4
+ DATA -
DATA 1-4 VIDEO 1-4
28VAC
24VAC
28VAC
24VAC
28VAC
24VAC
28VAC
24VAC
OFF
OFF
OFF
OFF
AUX1 AUX2 AUX3 AUX4
Plug the RJ45 connector at one end of a structured cable into the RJ45 jack marked [Data 1-4] of the HubSat4D
(F
ig. 1h, pg. 4).
Plug the RJ45 connector at the opposite end of the structured cable into the corresponding RJ45 channel jack of the HubWay/HubWayLD/HubWayLDH UTP Transceiver Hubs (Fig. 6, pg. 7). When using f
ixed cameras disregard this step. Example: Using RJ45 jack marked [Video 1-4] of HubSat4D connected to [Channels 1-4] of the HubW
ay/HubWayLD/HubWayLDH for video transmission, Using the RJ45 jack marked [Data 1-4] of HubSat4D connected to the Channel jack marked [4] of the HubWay/HubWayLD/HubWayLDH. Note: Channels 1-3 can not be used for video transmission when using the RJ45 jack marked [CH 1-4] of the HubW
ay/HubWayLD/HubWayLDH. The output voltage switches 1-4 must be set to OFF position (Fig. 6, pg. 7).
7. Connect Video Balun/Combiner at camera 1 to the HubSat4D unit utilizing CAT-5 or higher structured cable. Plug the RJ45 connector at one end of a str
uctured cable into the RJ45 jack marked [PVD1] of the HubSat4D (Fig. 1e, pg. 4). Plug the RJ45 connector at the opposite end of the structured cable into the RJ45 jack of the
Video Balun/Combiner located at camera 1.
• For 24VAC cameras use Altronix model HubWayAv Video Balun/Combiner (Figs. 2a, 2b, pg. 6).
For 12VDC cameras use Altronix model HubWayDv Video Balun/Combiner (Figs. 2c, 2d, pg. 6).
A
C LED (Green) of the HubWayAv or DC LED (Red) of the HubWayDv Video Balun/Combiners will illuminate indicating power is present at the cameras (Fig. 2b, 2d, pg. 6). Repeat this step for each additional camera [OUT2-4]. Note: The combined total cable distance for video transmission must not exceed the following distances:
-
750 ft. between the HubWay and each camera routed through the HubSat4D.
- 3000 ft. between the HubWayLD/HubWayLDH and each camera routed through the HubSat4D.
8. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 4, pg. 6) and measure the output v to insure proper operation and a
oltage at the power output of each Video Balun/Combiner (Figs. 2b, 2d, pg. 6) before powering each camera
void possible damage.
Fig. 1 - HubSat4D Circuit Board
1c - Power Terminals: 24VAC/28VAC power outputs.
1b - Output
PTCs: Protects each output.
1a - BNC Connector: Video
in from remote camera video out to D
VR.
1i - Channels 1-4:
CAT
-5 or higher structured cable to cameras.
1h - Data: CAT-5 or higher structured cable to data port on HubWay8/16, HubWayLD8/16, HubWayLDH8/16 or head end equipment (DVR).
1d - Output Voltage Switches:
Selects 24V
AC/28VAC/OFF
for each output.
1e - LED(s) 1-4:
Power output indicators.
1f - Data:
RS422/RS485 input from head end equipment (D
VR) for PTZ
control.
1g - Channels 1-4: Single CAT-5 or higher structured cable out to HubWay8/16, HubWayLD8/16, HubWayLDH8/16 enables transmission of up to four (4) video signals.
- 4 - HubSat4D
• HubWayAv - Terminals marked [AC POWER] (Figs. 2a, 2b, pg. 6).
• HubW
9. Set illuminated master power disconnect circuit breaker to the (OFF) position (F
ayDv - Terminals marked [– 12VDC +] (F
igs. 2c, 2d, pg. 6).
ig. 4a, pg. 6).
10. Connect the power outputs of the HubWayAv or HubWayDv Video Balun/Combiners to the power inputs of the cameras (Figs. 2a-2d, pg. 5). Polarity must be observed.
11.
Connect the terminals marked [+ DATA -- ] of the HubWayAv or HubWayDv Video Balun/Combiners to the data terminals of the cameras for PTZ control (Figs. 2a-2d, pg. 5). Polarity must be observed. When using fixed cameras disregard this step.
12.
Connect the BNC connector of the HubWayAv or HubWayDv Video Balun/Combiners to the BNC video outputs of the cameras (Figs. 2b-2d, pg. 6).
13.
Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 4a, pg. 6).
14. The power LEDs (Green) or Channels 1-4 of the HubSat4D will illuminate when AC power is present
(Fig. 1e, pg. 4). If any of these LEDs are off, a loss of AC power output may be due to a blown fuse or a tripped PTC caused b
y a short circuit or overload condition. If all of the LEDs are OFF there may be a complete loss of supply power to the HubSat4D unit or the illuminated master power disconnect circuit breaker is in the OFF position or the primary in-line fuse is blown.*
To restore the power output for HubSat4D:
1- Switch corresponding output voltage switch to the OFF position (Fig. 1d, pg. 4). 2-
Eliminate the trouble condition. 3- Allow 1 minute for PTC to cool off. 4- Switch output voltage switch to the 24VAC or 28VAC position as desired (Fig. 1d, pg. 4).
*Note: Replace fuse with same type and rating:
Primary in-line fuse is rated @ 3.5A/250V (Fig. 4b, pg
. 6).
Primary In-line Fuse
Alternate 24VAC fixed camera hookup (Fig. 6a, pg. 7).
After completing steps 1-5 from Installation Instructions Remote Accessory Module for use with HubWay/HubWayLD/HubWayLDH UTP Transceiver Hubs proceed with the follo
wing.
1. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 4a, pg. 6).
2.
Connect one end of the coaxial cable to the BNC connector marked [Video1] of the HubSat4D (Fig. 1a, pg. 4). Connect the opposite end of the coaxial cable to the BNC video output of camera 1 (Fig
. 6a, pg. 7).
3. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 4a, pg. 6) measure the output v
oltage at terminal pair marked [AUX1] of the HubSat4D to insure proper operation and
avoid possible damage (Fig. 1b, pg. 4).
4.
Connect the power output terminal pair marked [AUX1] to the power inputs of camera 1 (Fig. 1c, pg. 4). Repeat steps 1-3 for each additional camera (Channels 2-4).
HubWay Video Balun/Combiner Reference Chart:
Altronix Model Number
HubWayAv
HubWayDv
HubSat4D - 5 -
*24VAC/28VAC *24VAC/28VAC
12VDC *24VAC/28VAC
to camera
Output Voltage
from HubSat
Input Voltage
Camera Type
Use with AC cameras
Use with DC cameras
Power LED
Green
Red
*Based on camera load and structured cable length.
1 - White/Orange [VIDEO +] 2 - Orange [VIDEO -- ] 3 - White/Green [DATA +] 4 - Blue [AC 1] 5 - White/Blue [AC 2] 6 - Green [DATA -- ] 7 - White/Brown [AC 2] 8 - Brown [AC 1]
V
IDEO BALUN/COMBINER
CAT5 + DATA -- POWER
+ DATA --
AC
VIDEO
HubWayAv
V
IDEO
A
C Power
to Camera
Data to C
amera
--
Green Power LED
1
2VDC Power
to Camera
+
--
Red Power LED
R
emovable
Terminal Block
R
J45 Jack
R
emovable
Terminal Block
R
J45 Jack
To BNC
C
onnector
of Camera
To BNC
C
onnector
of Camera
S
tructured
Cable from
HubSat4D
S
tructured
Cable from
HubSat4D
+
D
ata to
Camera
-­+
VIDEO BALUN/COMBINER
HubWayDv
Fig. 2 - HubWayAv and HubWayDv Video Balun/Combiners
White
Lead
Black Lead
non power-
limited
non power-limited
Green Lead
(Ground)
115VAC
Input
50/60 Hz.
XFMR
PVD1
VIDEO1 VIDEO2 VIDEO3 VIDEO4
PVD2 PVD3 PVD4
+ DATA -
DATA 1-4 VIDEO 1-4
28VAC
2
4VAC
28VAC
2
4VAC
28VAC
2
4VAC
28VAC
2
4VAC
OFF
OFF
OFF
OFF
AUX1 AUX2
BK
2
4(YL)
0 (Br)
AUX3 AUX4
Primary
In-line
Fuse
(ON)
Fig. 2a
Fig. 2c
Fig. 2b Fig. 2d
HubWayAv passes AC voltage through pins 4, 5, 7, 8 and
C Power] terminals.
[A
Fig. 3 - CAT5 Wiring Color Codes
Fig. 4
Fig
. 4a
Illuminated master power disconnect circuit breaker:
• OFF position Circuit breaker tripped – Switch not illuminated.
• RESET (ON) position – Switch illuminated.
HubWayDv converts AC voltage to DC voltage through pins 4, 5, 7, 8 and [-- 12VDC +] terminals.
Primary In-line fuse: Rated @ 3.5A/250V
Fig. 4b
- 6 - HubSat4D
Data
Video
Head End Equipment (DVR)
R
S485
Monitor
Rear
Front
1
234CH 1-4 CH 5-8
28VAC OFF 24VAC
+ DATA -
1
-8
5
678
PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE
AC POWER
GAIN
87654321
Video (Coax)
Power
Video (Coax)
Power
24VAC
Fixed
Camera
Video (Coax)
Power
24VAC/28VAC
Camera Power
Provided
by HubSat4D
115VAC
Input, 50/60Hz
24VAC
Fixed
Camera
Video
Power
HubWayDv
Video Balun
Combiner
CAT-5
CAT-5
CAT-5
12VDC
Fixed
Camera
HubWayAv
Video Balun
Combiner
24VAC
PTZ
Camera
Four (4) Video
signals on a single CAT-5
Data (CAT-5)
Four (4) Video
signals on a single CAT-5
24VAC/28VAC
Camera Power
Provided
by HubSat4D
115VAC
Input, 50/60Hz
HubWayDv
Video Balun
Combiner
Video
Data
Power
Video
Data
Power
12VDC
PTZ
Camera
CAT-5
HubWayAv
Video Balun
Combiner
24VAC
Fixed
Camera
Video Power
24VAC
Fixed
Camera
Video (Coax)
Power
24VAC
Fixed
Camera
Typical Application Drawing for
115VAC Input,
50/60Hz
Head End Equipment (DVR)
RS485
B
NC
D
ata
V
ideo
P
ower
C
AT-5
V
ideo
P
ower
HubWayAv
Video Balun
Combiner
HubWayAv
Video Balun
Combiner
CAT-5
CAT-5
C
AT-5
24VAC PTZ
Camera
HubWayDv Video Balun Combiner
HubWayDv Video Balun Combiner
Video
Data
Power
V
ideo
Data
Power
24VAC/28VAC Camera Power Provided by HubSat4D
24VAC Fixed
Camera
12VDC PTZ
Camera
Monitor
12VDC Fixed
Camera
HubSat4D as a Passive UTP Transceiver Hub with Integral Camera Power:
Fig. 5
Typical Application Drawing for HubSat4D as a Remote Accessory Module
for use with HubWay/HubWayLD/HubWayLDH UTP Transceiver Hubs:
Fig. 6
HubSat4D - 7 -
Fig. 6a - Alternate 24VAC fixed camera hookup.
The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated “DANGEROUS VOLTAGE” within the products enclosure that may be of sufficient magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Enclosure Dimensions:
8.5”H x 7.5”W x 3.5”D
CAUTION: To reduce the risk of electric shock do not open enclosure. There are no user ser
viceable parts inside. Refer servicing to qualified service personnel.
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 website: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A. IIHubSat4D E29H
- 8 - HubSat4D
MEMBER
Loading...