Altronix eBridge4SK Installation Instructions

Rev. 072313
Installation Guide
PLUS
eBridge100SPR - EoC Receiver eBridge4SPT - 4 Port PoE/PoE+ EoC Transceiver Switch
Overview:
Features:
Agency Listings:
• UL/CUL Listed for Information Technology Equipment (UL 60950-1).
• CE approved.
Input:
• eBridge100SPR - 51-56VDC/60W max. power.* eBridge4SPT - powered by eBridge100SPR.
Power Output:
• eBridge4SPT: 4 ports PoE+ (30W) per port.
• Total output power: 60W.
Ethernet:
• Connectivity: RJ45, auto-crossover.
• Wire type: 4-pair Cat-5e or better structured cable.
• Distance: up to 100m.
• Speed: 10/100BaseT, half/full duplex, auto negotiation.
Coax:
• Distance: up to 300m.
• Connectivity: BNC, RG-59/U or similar.
• Throughput is rated to pass 100mbps from camera to receiver. With the proper headend equipment multiple Megapixel cameras can be used.
LED Indicators:
• Blue LED - Coax link connection.
*UL Listed Class 2 or limited power source (NetWay1D).
LED Indicators (cont’d):
• Green LED - Power (eBridge100SPR only).
• Yellow and Green LED (RJ45) IP Link status, 10/100Base-T/active.
Environmental:
Operating Ambient Temperature : eBridge100SPR: -40ºC to 60ºC (-40ºF to 140ºF). eBridge4SPT: 60W: -40ºC to 75ºC (-40ºF to 167ºF).
• Storage Temperature: -40ºC to 75ºC (-40ºF to 167ºF).
• Humidity: 20 to 85%, non-condensing.
Applications:
• Retrofit digital IP cameras in an analog CCTV installation (up to four (4) IP cameras expansion per analog camera).
• Works with Megapixel, HD720, HD1080 and VGA (SD) cameras (see note, pg. 2).
• Extend Network link distance in an industrial environment.
• Upgrade deployed CCTV Coax to a digital network in Retail, Hospitality, Arenas, Casinos, Airports, Schools, Hospitals, Transportation, etc.
Mechanical:
• Dimensions (H x W x D approx.): eBridge100SPR: 4.375” x 3.5” x 1” (111.125mm x 88.89mm x 25.4mm) eBridge4SPT: 1.7” x 5.23” x 8.93” (43.18mm x 132.84mm x 226.82mm)
I.T.E. 43KC
eBridge4SK - 1 -
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the application. eBridge100SPR and eBridge4SPT is not intended to be connected to outside plant leads and should be installed indoors within the protected premises. The eBridge100SPR and eBridge4SPT is intended for indoor use only.
1. eBridge100SPR installation: a. Secure unit to desired mounting surface with a proper fastening device utilizing the unit’s mounting hole. Unit should be mounted in proximity to Ethernet switch/network, NVR or video server. b. Connect 56VDC UL Listed Class 2 or limited power source to terminals marked [Power --- Input +] (observe proper polarity) (Fig. 1, pg. 3). Use 22AWG-16AWG wire for this connection. Caution: 56VDC will be present on coax. The other end of the coax should only be connected to the eBridge4SPT. c. Connect structured cable from Ethernet switch/NVR (network video server) to RJ45 jack marked [10/100 BaseT] (Fig. 1, pg. 3). d. Connect Coax cable to BNC connector marked [Coax] (Fig. 1, pg. 3).
2. eBridge4SPT installation: a. Affix rubber pads to eBridge4SPT for shelf installation (Fig. 9, pg. 12). b. Connect Coax cable from eBridge100SPR to BNC connector marked [Coax] located on the back of the unit (Fig. 1, pg. 3). c. Connect structured cable from PoE/PoE+ cameras/devices to RJ45 jacks marked [1-4] (Fig. 1, pg. 3).
Note: The eBridge is designed to accommodate Megapixel, HD720, HD1080 and VGA (SD) cameras. It is important to note that some high resolution and high frame rate cameras may demand faster headend processing ability, such as a PC graphics card to present a quality image. If the headend processing equipment is insufficient in speed, the image may show pixelation and latency. It is advisable to pretest system if unsure. Alternatively, frame rate and resolution may be reduced to accommodate system equipment.
Technical Specifications:
Parameter Description
Connections BNC for Coax link. RJ45 for Ethernet link.
Input power requirements
Indicators
eBridge100SPR - 51-56VDC/60W @ max. power. eBridge4SPT - powered by eBridge100SPR.
Blue: Coax Link. Yellow (RJ45 connector): On - Link, Off - No Link, Blinking - Activity. Green (RJ45 connector): On - 100Base-TX, Off - 10Base-T.
Operating Ambient Temperature (UL60950-1): eBridge100SPR: -40ºC to 60ºC (-40ºF to 140ºF).
Environmental Conditions
eBridge4SPT: 60W: -40ºC to 75ºC (-40ºF to 167ºF). Relative humidity: 85%, +/ --- 5% Storage Temperature: --40ºC to 75ºC (-40ºF to 167ºF). Operating Altitude: --- 1000 to 6,561.679 ft. (--- 304.8 to 2000m).
Regulatory Compliance UL/CUL Listed for Information Technology Equipment (UL 60950-1). CE approved.
Weights (approx.)
- 2 - eBridge4SK
eBridge100SPR - Product: 5.1 oz. (0.144 kg.), Shipping: 7.76 oz. (0.22 kg.) eBridge4SPT - Product: 2.9 lbs. (1.32 kg), Shipping: 3.9 lbs. (1.77 kg)
Fig. 1
eBridge100SPR
Ethernet Switch
56VDC
Input
Coax up to 300m
Typical Application:
eBridge4SPT (Front View)
PoE
Output
10/100
Base-T
CAT-5e
up to 100m
NVR Network
Video Server
(Head End
Equipment)
CAT-5e
up to
100m
PoE/PoE+
Cameras
CAT-5e
up to
100m
PoE/PoE+
Cameras
Maximum Length of Coax Type vs. Camera Power/PoE Class:
Camera Power/ PoE Class
RG59/U
(23AWG)
13W/0 or 13W/3 260.64m 335.28m 500m 500m 500m 25W 118.9m 150.6m 239.3m+ 365.8m+ 365.8m+ 60W 50.3m+ 63.4m+ 100.6m+ 160m+ 160m+ 90W 33.5m 42.1m 67.1m+ 106.4m+ 106.4m+ 120W 25m 31.7m 50.3m+ 80.2m+ 80.2m+
RG59/U
(22AWG)
RG59/U
(20AWG)
Max. Length (meters)
RG59/U
(18AWG)
RG6/U
(18AWG)
Internet Browser Setup
Factory Default settings
• IP Address: 192.168.168.168
• User Name: admin
• Password: admin
1. Set the static IP address for the laptop to be used for programming to the same network IP address as the eBridge4SPT, i.e. 192.168.168.200 (the default address of the eBridge4SPT is 192.168.168.168).
2. Connect one end of the network cable to the network jack on the eBridge100SPR and the other to the network connection of the laptop.
eBridge4SK - 3 -
3. Open a browser on the computer and enter “192.168.168.168” into the address bar. A dialog box Authentication Required will appear requesting both user
Site ID Trap Message
USB Network Setup
DEVICE ALERTS
WEBVIEW INTERFACE
name and password enter the default values here. Click on the button labeled Log In.
4. The status page of the eBridge4SPT will appear. This page displays the real time status and health of each device connected to the eBridge4SPT.
Network Setup:
Click on the tab labeled Network Settings. This will open the Network Setting screen. In this screen the MAC Address of the eBridge4SPT module will be found along with the programming fields for the Network Settings, Trap Receiver Settings, SNMP Port Settings and Email Settings.
Network Settings: In the IP Address Method field select the method that the IP Address for the eBridge4SPT will be obtained “Static” or “DHCP” then follow the appropriate steps.
Fig. 2
STATIC (Fig. 2a, pg. 4):
1. IP Address: Enter the IP address assigned to the eBridge4SPT by the network administrator.
2. Subnet Mask: Enter the Subnet of the network.
3. Gateway: Enter the TCP/IP gateway of the network access point (router) being used.
eBridge4SPT
Site ID: RJ Sports Wear Site ID: RJ Sports Wear
Network Settings:
Note: Gateway configuration is required to properly receive emails from the device.
4. HTTP Port: Enter the HTTP port number assigned to the eBridge4SPT module by the network administrator to allow remote access and monitoring. The default inbound port setting is 80. HTTP is not encrypted and unsecure. Even though HTTP can be used for remote access it is recommended primarily for use with LAN connections.
5. HTTPS Port: Enter the HTTPS port number assigned to the eBridge4SPT module by the network administrator to allow remote access and monitoring. The default inbound port setting is 443. Being encrypted and more secure, HTTPS is highly recommended for remote access.
6. Click the button labeled Submit Network Settings. A dialog box will display “New network settings will take effect after the server is rebooted”. Click OK.
DHCP (Fig. 2a, pg. 4):
Trap Receiver Settings:
Trap Receiver IP Address 1:
Trap Receiver IP Address 2:
Trap Receiver IP Address 3:
Trap Receiver IP Address 4:
Trap Receiver IP Address 5:
1. After selecting DHCP in the IP Address Method field click the button labeled Submit Network Settings. A dialog box will display “New network settings will take effect after the server is rebooted”. Click OK. Next click on the button
SNMP Port Settings:
labeled Reboot Server. After rebooting the eBridge4SPT will be set in the DHCP mode. The IP address will be assigned by the router when the eBridge4SPT is connected to the network. It is recommended to have the assigned IP Address reserved to ensure continued access (see the network administrator).
2. Subnet Mask: When operating in DHCP the router will assign the subnet mask values.
3. Gateway: TCP/IP gateway of the network access point (router) being used will be displayed.
IP Address Method:
Subnet Mask:
HTTPS Port:
MAC Address: BC:34:00:30:00:B3
Submit Trap Receiver IP Settings
Trap Message Port:
IP Address:
10.0.0.113
255.255.255.0
Gateway:
10.0.0.1
HTTP Port:
2713
443
Submit Network Settings
10.0.0.102
10.0.0.56
62.19.75.80
45.165.245.146
50.74.175.125
SNMP Port:
161
162
Submit Port Settings
STATIC
Security SettingsNetwork SettingsSetupStatus
Management Interface
Events Log
Email Settings:
a.
b.
From:
Subject:
Username:
Password:
SMTP Server:
SMTP Server Port:
Outgoing Email 1:
Outgoing Email 2:
Outgoing Email 3:
Outgoing Email 4:
Outgoing Email 5:
Test Email Restore Default Submit Email Settings
Restore Factory Settings
c.
Network Settings
event.report@linqinfo.com
event.report
••••••••
smtp.gmail.com
587
mike@jrsport.com
steve@jrsport.com
amy@jrsport.com
scott@jrsport.com
maria@jrsport.com
Reboot Server
v1.99.22
d.
- 4 - eBridge4SK