![](/html/68/68ed/68ed9d2981d2da6a0a520bf6df92879f0f84f00a2d6cb64b70af07873214ab64/bg1.png)
ALTV615DC8ULCB
Door
Green
Lead
Wire
Strap
(from
Enclosure
to Door)
XFMR
Black
Lead
White
Lead
115VA C input
50/60 Hz,
.9 amp
non-power
limited
Keep power limited outputs away from all other wiring 1/4" spacing
must be provided.
power limited
Use separate
knockouts for
power limited
circuits.
PD8ULCB
N
COMMON POWER OUTPUTS
P
FUSED POWER OUTPUTS
1 2 3 4 5 6 7 8
ALTRONIX CORP
. MADE IN USA
BROOKLYN, NY 11220
D1
INPUT
R1
LED
F1 F2 F3 F4 F5 F6 F7 F8
+ DC -
- BAT +
AC AC
DC
AC
Voltage
Adjustment
AL400ULB
CCTV Camera & Accessory Power Supply
Rev. 110403
Overview:
The Altronix ALTV615DC8ULCB CCTV Power Supply is designed with eight (8) individually PTC power limited,
Class 2 Rated outputs for powering CCTV Cameras and other video accessories. It will provide 6VDC-15VDC
distributed via eight (8) PTC outputs with a total of up to 4 amp continuous supply current.
Specifications:
• UL Listed for Commercial
CCTV Equipment (UL2044).
• CUL Listed - CSA Standard C22.2 No.1-98,
Audio, Video and Similar Equipment.
• Input 115VAC 50/60 Hz, .9 amp.
• 6VDC-15VDC adjustable output.
• Eight (8) individually PTC protected power limited,
Class 2 Rated outputs.
• 4 amp total continuous supply current.
• Filtered and electronically regulated outputs.
PTC protected outputs are rated @ 2.5 amp (
•
• AC input and DC output LED indicators.
• Power ON/OFF switch.
• Unit maintains camera synchronization.
• Ease of installation saves time and eliminates costly labor.
Enclosure Dimensions:
13"H x 13.5"W x 3.25"D
Fig.1).
Installation Instructions:
1. Mount ALTV615DC8ULCB in desired location.
2. Connect green lead to earth ground. Connect AC
(115VAC 50/60 Hz) to the black and white flying
leads of the transformer (Fig. 1). Use knockout
adjacent to the transformer 1/4” spacing must be provided between AC input wiring and all other circuits.
3. Adjust output voltage using trimpot on the board prior to connecting CCTV devices.
4. Switch SW1 (Fig. 1) to OFF position.
5. Measure output voltage before connecting devices. This helps avoid potential damage.
erminals marked [1P-8P] are positive (+) and terminals marked [1N-8N] are negative.
T
CAUTION: Determine the maximum operating voltage of the equipment being powered before adjusting the
output voltage.
Connect each DC CCTV cameras to terminal pairs marked [1P-1N thru 8P-8N] on PD8 board
6.
observing correct polarity.
7. Switch SW1
8. Green LED will illuminate when when unit is powered.
9. Upon completion of wiring, secure enclosure door with screws (supplied).
Keep power
Use separate knockouts.
Caution: Equipment to be installed / serviced by authorized / trained personnel only.
Shut branch circuit power before installing / servicing equipment.
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture.
This installation should be made by qualified service personnel and should conform to NEC and all
local codes.
(Fig. 1) to ON position.
limited cir
cuits (outputs 1 through 8) away from non-power limited, 1/4” space must be provided.
(Fig. 1) carefully
Fig. 1
![](/html/68/68ed/68ed9d2981d2da6a0a520bf6df92879f0f84f00a2d6cb64b70af07873214ab64/bg2.png)
00
0
.81"
0
1.1875"
1.1875"
3.25"
3.25"
0 1.1875" 3.25".75" 1.5" 6.25" 11"
1.4"
6.5"
5.5"
1.4"
11.66"
12.1"
13"
12.5"
11.75"
TOP ONLY
Terminal Identification:
AL400ULB - Power Supply Board
T
erminal Legend Function/Description
AC/AC Low voltage AC input (24VAC 100VA) Altronix part #T24130
+ DC - 6VDC-15VDC @ 4 amp total continuous output.
PD8ULCB - Distribution Module
1P - 8P Positive DC output, class 2, power limited.
1N - 8N Negative DC output, class 2, power limited.
Enclosure Dimensions:
13”H x 13.5”W x 3.25”D
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
web site: www.altronix.com, e-mail: info@altronix.com, Made in U.S.A.
IIALTV615DC8ULCB
H06D