![](/html/d0/d009/d009e7fc1e7a2768ffeb267acb181cd84aa42860c3f310ed8e885348c3a80fac/bg1.png)
ALTV615DCUL Series
CCTV Power Supplies
Installation Guide
Models Include:
• ALTV615DC44ULM • ALTV615DC44ULCBM
- 6-15VDC @ 4A - 6-15VDC @ 4A
- Four (4) Fuse Protected Outputs. - Four (4) PTC Protected Outputs.
• ALTV615DC48ULM • ALTV615DC48ULCBM
- 6-15VDC @ 4A - 6-15VDC @ 4A
- Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.
• ALTV615DC416UL • ALTV615DC416ULCB
- 6-15VDC @ 4A - 6-15VDC @ 4A
- Sixteen (16) Fuse Protected Outputs. - Sixteen (16) PTC Protected Outputs.
• ALTV615DC616UL • ALTV615DC616ULCB
- 6-15VDC @ 6A - 6-15VDC @ 6A
- Sixteen (16) Fuse Protected Outputs. - Sixteen (16) PTC Protected Outputs.
• ALTV615DC416ULCBM*
- 6-15VDC @ 4A
- Sixteen (16) PTC Protected Outputs.
For models with line cord installed : For 3-wire add suffix “3” e.g. ALTV615DC44ULM3.
*Same except for enclosure size
Rev. 050404
![](/html/d0/d009/d009e7fc1e7a2768ffeb267acb181cd84aa42860c3f310ed8e885348c3a80fac/bg2.png)
Overview:
ALTV615DCUL Series DC CCTV Power Supplies provide 6-15VDC distributed via fuse or PTC protected outputs for
powering CCTV Cameras, heaters and other video accessories.
ALTV615DCUL Reference Chart:
Altronix
Total Output
Current
Model Number
ALTV615DC44ULM
ALTV615DC44ULCBM
ALTV615DC48ULM
ALTV615DC48ULCBM
ALTV615DC416UL
ALTV615DC416ULCB
ALTV615DC616UL
ALTV615DC616ULCB
ALTV615DC416ULCBM*
*Same except for enclosure size.
(Power)
4A 6-15VDC 4 4A 6-15VDC 4
4A 6-15VDC 8 4A 6-15VDC 8
4A 6-15VDC 16 4A 6-15VDC 16
6A 6-15VDC 16 - 6A 6-15VDC 16
4A 6-15VDC 16
Output Voltage
Number of
Outputs
PTC Protected
P P
P P
P P
P P
P P
Outputs
Class 2 Rated
Power-Limited
P P
P P
P P
P
Fuse Protected
Outputs
Output Current
(max per output)
3.5A 0.9A
- 2.5A 0.9A
3.5A 0.9A
- 2.5A 0.9A
3.5A 0.9A
- 2.5A 0.9A
3.5A 1.5A
- 2.5A 1.5A
- 2.5A 0.9A
115VAC 50/60Hz
Input Current
Agency Listings
Specifications:
Agency Listings:
• UL Listed for Commercial CCTV Equipment (UL 2044).
CUL Listed - CSA Standard C22.2 No.1-98, Audio,
Video and Similar Equipment.
Input:
• Input 115VAC, 50/60 Hz.
Output:
• Four (4), eight (8), or sixteen (16) individual outputs.
• 6VDC to 15VDC field adjustable.
• Outputs are rated @ 3.5A (fused) or 2.5A (PTC).
• Filtered and electronically regulated outputs.
Features:
• AC input and DC output LED indicators.
• Power ON/OFF switch.
• Unit maintains camera synchronization.
• Ease of installation saves time and eliminates
costly labor.
Enclosure Dimensions (H x W x D approx.):
ALTV615DC44ULM, ALTV615DC44ULCBM,
ALTV615DC48ULM, ALTV615DC48ULCBM, and
ALTV615DC416ULCBM:
8.5” x 7.5” x 3.75” (215.9mm x 190.5mm x 97.9mm).
All other models:
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.55mm).
CAUTION: This installation should be made by qualified service personnel and should conform to all
local codes and in accordance with the National Electrical Code.
Installation Instructions:
1. Mount unit in the desired location.
2. Remove Power Distribution Module and isolation barrier (models with “M” suffix only).
3. Connect AC power to the two black and two white flying leads of the transformer (Figs. 1 - 4, pgs. 4 - 6).
Units with linecord installed skip Instruction #3.
Use 18 AWG or larger for all power connections. Connect green ground lead to earth ground (Fig. 1 - 4, pgs. 4 - 6).
Keep power-limited wiring separate from non power-limited wiring. Minimum 0.25” spacing must be
provided. Use separate knockouts.
4. Adjust output voltage (unit is factory set at 12VDC): use the trimpot on the power supply board
prior to connecting CCTV devices.
5. Measure output voltage before connecting devices. This helps avoiding potential damage.
CAUTION: Determine the maximum operating voltage of the equipment being powered before adjusting the
output voltage.
6. Reinstall isolation barrier and Power Distribution Module (models with “M” suffix only).
- 2 - ALTV615DCULSeries
![](/html/d0/d009/d009e7fc1e7a2768ffeb267acb181cd84aa42860c3f310ed8e885348c3a80fac/bg3.png)
7. Connect devices to the terminals marked [1P - 1N] through [4P - 4N] on PD4/PD4CB board,
[1P - 1N] through [8P - 8N] on PD8/PD8CB, [1P - 1N] through [16P - 16N] on PD16W/PD16WCB/PD16CB board,
carefully observing correct polarity (Figs. 1 - 4, pgs. 4 - 6).
Terminals marked [1P - 16P] are positive (+) and terminals marked [1N - 16N] are negative.
8. Green LED will illuminate when unit is powered.
9. Upon completion of wiring secure enclosure door with screws (supplied).
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture.
Terminal Identification:
Power Supply Board
Terminal Legend Function/Description
AC/AC Low voltage AC input.
+ DC -- 6VDC-15VDC output.
PD4UL/PD4ULCB - Distribution Module
1P - 4P Positive DC outputs.
1N - 4N Negative DC outputs.
PD8UL/PD8ULCB - Distribution Module
1P - 8P Positive DC outputs.
1N - 8N Negative DC outputs.
PD16W/PD16WCB/PD16CB - Distribution Module
1P - 16P Positive DC outputs.
1N - 16N Negative DC outputs.
The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the
presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient
magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open enclosure. There are
no user serviceable parts inside. Refer servicing to qualified service personnel.
ALTV615DCULSeries - 3 -