ALTV615DC220 Series DC CCTV Power Supplies provide 6-15VDC distributed via fuse or PTC protected outputs for
powering CCTV cameras, heaters, and other video accessories.
CAUTION: This installation should be made by qualified service personnel and should conform to the
National Electrical Code and all local codes.
Installation Instructions:
1. Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the
enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s
upper keyholes over the two upper screws, level and secure. Mark the position of the lower two holes. Remove the
enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s upper keyholes over the two
upper screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 7, 8).
2. Remove Power Distribution Module and isolation barrier (models with “M” suffix only).
3. Connect unswitched AC circuit (220VAC, 50/60Hz) as follows: Green branch wire (ground) connects to the terminal
marked , Line connects to the terminal marked [L], and Neutral connects to the terminal marked [N] of the Inlet
Appliance Connector. (Figs. 1-4, pgs. 4-6). Use 18 AWG or larger for all power connections.
Units with line cord installed skip Instruction #3.
Use 18 AWG or larger for all power connections. Connect green ground lead to earth ground(Fig. 1-4, pgs. 4-6).
Keep power-limited wiring separate from non power-limited wiring. Minimum 0.25” spacing must be provided. Use separate knockouts.
4. Adjust output voltage (unit is factory set at 12VDC): use the trimpot on the power supply board
prior to connecting CCTV devices.
5. Measure output voltage before connecting devices. This helps avoiding potential damage.
CAUTION:Determine the maximum operating voltage of the equipment being powered before adjusting the
output voltage.
- 2 - ALTV615DC220 Series
Page 3
6. Reinstall isolation barrier and Power Distribution Module (models with “M” suffix only).
7. Connect devices to terminals marked [1P - 1N] through [4P - 4N] on PD4/PD4CB board,
[1P - 1N] through [8P - 8N] on PD8/PD8CB, [1P - 1N] through [16P - 16N] on PD16W/PD16WCB/PD16CB board,
carefully observing correct polarity (Figs. 1-4, pgs. 4-6).Terminals marked [1P - 16P] are positive (+) and terminals marked [1N - 16N] are negative.
8. Green LED will illuminate when unit is powered.
9. Upon completion of the wiring, secure enclosure door with screws (supplied).
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture.
Terminal Identification:
Power Supply Board
Terminal LegendFunction/Description
AC/ACLow voltage AC input.
+ DC --6VDC-15VDC output.
PD4/PD4CB - Distribution Module
1P - 4PPositive DC outputs.
1N - 4NNegative DC outputs.
PD8/PD8CB - Distribution Module
1P - 8PPositive DC outputs.
1N - 8NNegative DC outputs.
PD16W/PD16WCB/PD16CB - Distribution Module
1P - 16PPositive DC outputs.
1N - 16NNegative DC outputs.
The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the
presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient
magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open enclosure. There are
no user serviceable parts inside. Refer servicing to qualified service personnel.
ALTV615DC220 Series - 3 -
Page 4
Y
A
A
Fig. 1
BK
A
AC
ALTV615DC44M220 • ALTV615DC44CBM220
CAUTION: De-energize unit prior to servicing. For continued protection against fire hazard
replace fuse with the same type and rating. Do not expose unit to rain or moisture.
Used on PTC Models
(example: ALTV615DC44CBM220)
1P, 2P, 3P, 4P = FUSED OUTPUTS
1P 1N 2P 2N 3P 3N 4P 4N
INPUT
1N, 2N, 3N, 4N = COMMON OUTPUTS
LED
ON OFF
F1F2F3F4
MAIN FUSE
Fig. 2
ALTV615DC48M220 • ALTV615DC48CBM220
Power
Supply
Board
Trimpot
Output Wiring
1P 1N 2P 2N 3P 3N 4P 4N
ALTRONIX CORP.BKLYN., NY 11220
LED
INPUT
ON OFF
220VAC Input
50/60 Hz
1P, 2P, 3P, 4P = FUSED OUTPUTS
1N, 2N, 3N, 4N = COMMON OUTPUTS
3.5A 250V
3.5A 250V
AC AC
3.5A 250V
XFMR
MAIN FUSE
Barrier
CAUTION: De-energize unit prior to servicing. For continued protection against fire hazard
replace fuse with the same type and rating. Do not expose unit to rain or moisture.
CAUTION: De-energize unit prior to servicing. For continued protection against fire hazard
replace fuse with the same type and rating. Do not expose unit to rain or moisture.
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
web site: www.altronix.com, e-mail: info@altronix.com. Lifetime Warranty, Made in U.S.A.
II1ALTV615DC220 Series B23Q
- 8 - ALTV615DC220 Series
MEMBER
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.