ALTV615DC Series
CCTV Power Supplies
Installation Guide
Models Include:
• ALTV615DC1016
- 6-15VDC @ 10 amp
- Sixteen (16) Fuse Protected
Outputs.
• ALTV615DC1016CB
- 6-15VDC @ 10 amp
- Sixteen (16) PTC Protected
Outputs.
For models with line cord installed : For 3-wire add suffix “3” e.g. ALTV615DC10163.
Rev. 102804

Overview:
These Altronix DC CCTV Power Supplies provide 6-15VDC distributed via sixteen (16) fuse or PTC protected outputs
for powering CCTV Cameras, heaters and other video accessories.
Sixteen (16) Output ALTV615DC Reference Chart:
Altronix
Model Number
ALTV615DC1016 10 amp 6-15VDC 16 - x 3.5 amp 1.9 amp
ALTV615DC1016CB 10 amp 6-15VDC 16 x - 2.5 amp 1.9 amp
(Power)
Total Output Current
Output Voltage
Outputs
Number of
Outputs
PTC Protected
Outputs
Fuse Protected
(max per output)
Output Current
115VAC
50/60Hz Input
Current
Specifications:
• Sixteen (16) individual outputs. • Ease of installation saves time & eliminates costly labor.
• Filtered and electronically regulated outputs. • Spare fuses included (on fuse protected models).
• Short circuit and thermal overload protection.
• Unit maintains camera synchronization. 13”H x 13.5”W x 3.25”D
Enclosure Dimensions:
Installation Instructions:
1. Mount unit in desired location.
2. Connect AC power to the two black and two white flying leads of the transformer (Fig. 1, pg. 3). Use 18 AWG or
larger for all power connections (Battery
Units with linecord installed skip Instruction #2.
3. Adjust output voltage using trimpot on the power supply board prior to connecting CCTV devices.
4. Measure output voltage before connecting devices. This helps avoid potential damage.
Terminals marked [1P - 8P] are positi
CAUTION: Determine the maximum operating voltage of the equipment being powered before adjusting the
output voltag
5. Connect devices to terminals marked [1P - 1N through 8P - 8N] on PD8UL/PD8ULCB board (Fig. 1, pg. 3) carefully
obser
ving correct polarity.
6. Green LED will illuminate when unit is powered.
7. Upon completion of wiring, secure enclosure door with screws (supplied).
Caution: Equipment to be installed / serviced by authorized / trained personnel only.
Shut br
e.
anch circuit power before installing / servicing equipment.
, DC output).
ve (+) and terminals marked [1N - 8N] are negative.
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture.
This installation should be made by qualified service personnel and should conform to all local codes
and in accordance with the National Electrical Code.
- 2 -

Door
CAUTION: De-energize unit prior to servicing. For continued protection against fire hazard
replace fuse with the same type and rating 3.5A, 250V. D o not expose unit to rain or moisture.
3.5A 250V
For continuous protection against
risk of fire replace fuses with
same type and rating.
c
ommon
o
utputs
protected
outputs
P
N
NPS
XFMR Input
PD16W
12345678
9
10 11 12 13 14 15 16
N
P
Wire Strap
(from
E
nclosure
t
o Door)
nonpower
limited
XFMR XFMR
Black Lead
White Lead
For models with
factory installed
3-wire line cord
115VAC input
50/60 Hz
Power Supply
Board
Used on PTC Models
(example: ALTV615DC1016CB)
P
N
PTC's
NPS
XFMR Input
Power Limited Class 2
PD16W
common
outputs
protected
outputs
12345678
9 10 11 12 13 14 15 16
P
N
DC outputs
DC outputs
Green
Lead
(ground)
Power
Switch
Terminal Identification:
Power Supply Board
Terminal Legend Function/Description
AC/AC Low voltage AC input.
DC -- 6VDC-15VDC output.
+
PD8UL/PD8ULCB - Distribution Module
1P - 8P Positive DC output.
1N - 8N
Negative DC output.
Fig. 1
- 3 -

5.10"
6.5625"
3.25"3.25"
5.10"
5.10"
3.25"
1.00"10.50"1.00"
1.00"
1.00"
1.40"
1.20"
1.40"
1
.20"
0.75
"0.75" 11.00"
12.50"
3.25"
0.9375"
0.9375"
1
.40" 4.85" 4.85" 1.40"
1.20"
Bottom
Top
RightLeft
The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the
presence of an insulated “DANGEROUS VOLTAGE” within the products enclosure that may be of sufficient
magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Enclosure Dimensions:
13”H x 13.5”W x 3.25”D
CAUTION: To reduce the risk of electric shock do not open enclosure. There are
no user ser
viceable parts inside. Refer servicing to qualified service personnel.
Altronix is not responsible for any typographical errors.
Altronix Corp.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
web site: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A.
II1ALTV615DCSeries K20G
- 4 -