Isolated Series
CCTV Power Supplies
Installation Guide
Models Include:
• ALTV248ULHi • ALTV248ULCBHi
- 24VAC @ 12.5A total output. - 24VAC @ 12.5A total output.
- Eight (8) 1.56A Fuse Protected - Eight (8) 1.56A PTC Protected
Isolated Outputs. Isolated Outputs.
• ALTV248ULMi • ALTV248ULCBMi
- 24VAC @ 12.5A total output. - 24VAC @ 12.5A total output.
- Eight (8) 1.56A Fuse Protected - Eight (8) 1.56A PTC Protected
Isolated Outputs. Isolated Outputs.
• ALTV2416ULi • ALTV2416ULCBi
- 24VAC @ 25A total output. - 24VAC @ 25A total output.
- Sixteen (16) 1.56A Fuse Protected - Sixteen (16) 1.56A PTC Protected
Isolated Outputs. Isolated Outputs.
Rev. 113004
Overview:
Altronix Isolated CCTV Power Supplies provide 24VAC distributed via eight (8) or sixteen (16) fuse or PTC protected
isolated outputs for powering CCTV cameras, heaters, and other video accessories.
Isolated Power Supply Reference Chart:
Altronix
Model Number
ALTV248ULHi
ALTV248ULCBHi
ALTV248ULMi
ALTV248ULCBMi
ALTV2416ULi
ALTV2416ULCBi
Add suffix “3” for 3-wire line cord (e.g. ALTV248ULHi3).
Output Voltage
24VAC 12.5A 8 24VAC 12.5A 8
24VAC 12.5A 8 24VAC 12.5A 8
24VAC 25A 16 24VAC 25A 16
Total Output
Current
Number of
Outputs
PTC Protected
Outputs
(Class 2
Power-Limited
for dry locations)
P
P
P
Fuse Protected
Outputs
Output Current
(max per output)
P
P
P
1.56A 3A
- 1.56A 3A
1.56A 3A
- 1.56A 3A
1.56A 6A
- 1.56A 6A
115VAC
50/60Hz Input
Current
Agency Listing
Specifications:
Agency Listings:
• UL Listed for Commercial CCTV Equipment (UL2044).
CUL Listed - CSA Standard C22.2 No.1-98, Audio,
Video and Similar Equipment.
Input:
• 115VAC, 50/60Hz.
Output:
• Eight (8) or sixteen (16) fuse or PTC protected outputs.
• 24VAC outputs.
• Outputs are rated @ 3.5A (fused) or 2.5A (PTC).
• Surge suppression.
Features:
• Individual electronically isolated outputs.
• Illuminated master Power ON/OFF switch
with built-in circuit breaker.
• Unit maintains camera synchronization.
• Ease of installation saves time & eliminates costly labor.
• Spare fuses included (on fuse protected models).
Enclosure Dimensions (H x W x D approx.):
ALTV248ULMi, ALTV248ULCBMi:
8.5” x 7.5” x 3.5” (215.9mm x 190.5mm x 88.9mm).
ALTV248ULHi, ALTV248ULCBHi,
ALTV2416ULi, and ALTV2416ULCBi:
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.55mm).
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI, and with all local
codes and authorities having jurisdiction. Product is intended for indoor use only.
1. Mount the unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the
enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s
upper keyholes over the two upper screws, level and secure. Mark the position of the lower two holes. Remove the
enclosure. Drill the lower holes and install the two fasteners. Place the enclosure’s upper keyholes over the two
upper screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 6-7).
Secure enclosure to earth ground (Figs. 1-3, pgs. 3-5).
2. Set power switch to OFF position on all models (Figs. 1-3, pgs. 3-5).
3. All units are factory set for 24VAC operation.
4. Secure green lead to earth ground. Connect AC power to the black and white flying leads of the transformer(s)
(Figs. 1-3, pgs. 3-5). Use 18 AWG or larger for all power connections.
Keep power-limited wiring (PTC protected outputs only) separate from non power-limited wiring.
Minimum 0.25” spacing must be provided. Use separate knockouts
5. Measure output voltage before connecting devices. This helps avoiding potential damage.
Terminals marked [1A - 8A] and [1B - 8B] are of the same polarity (phase).
6. Connect CCTV cameras to output terminals using the following procedure:
Camera 1 to output 1A & 1B. Camera 5 to output 5A & 5B.
Camera 2 to output 2A & 2B. Camera 6 to output 6A & 6B.
Camera 3 to output 3A & 3B. Camera 7 to output 7A & 7B.
Camera 4 to output 4A & 4B. Camera 8 to output 8A & 8B.
- 2 - UL Listed Isolated Series
7. Set power switch on all models to the “RESET” (ON) position (Figs. 1-3, pgs. 3-5).
8. Upon completion of the wiring, secure enclosure door with screws (supplied).
CAUTION: Equipment to be installed/serviced by authorized/trained personnel only.
Shut branch circuit power before installing/servicing equipment.
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This installation
should be made by qualified service personnel and should conform to all local codes and in accordance with the
o
National Electrical Code. Use 75
C or higher rated UL insulated wiring for connecting unit to the mains. Replace
fuses with same type and rating (3.5A/250V).
Terminal Identification:
PD8i - Power Distribution Module
1A - 8A Phase 1.
1B - 8B Phase 2.
Fig. 1
ALTV248ULHi • ALTV248ULCBHi
non power-limited
1A
2A 3A 4A 5A 6A 7A 8A
1B 2B 3B 4B 5B 6B 7B 8B
F1 F2 F3 F4 F5 F6 F7 F8
Used on PTC Models
(example: ALTV248ULCBHi)
Class 2 power-limited
1A
2A 3A 4A 5A 6A 7A 8A
1B 2B 3B 4B 5B 6B 7B 8B
F1 F2 F3 F4 F5 F6 F7 F8
Power
5A
Switch
250V
WARNING:
Change fuses with the
same type and rating:
Input: 5A @ 250V
Output: 3.5A @ 250V
XFMR*
Green
Lead
(ground)
115VAC input
50/60 Hz.
non power-limited
UL Listed Isolated Series - 3 -