ALTV248UL Series
CCTV Power Supplies
Installation Guide
Models Include:
• ALTV248UL • ALTV248ULCB
- 24VAC @ 3.5A (85VA) - 24VAC @ 3.5A (85VA)
or 28VAC @ 3A (85VA). or 28VAC @ 3A (85VA).
- Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.
• ALTV248175UL • ALTV248175ULCB
- 24VAC @ 7A (175VA) - 24VAC @ 7A (175VA)
or 28VAC @ 6.25A (175VA). or 28VAC @ 6.25A (175VA).
- Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.
• ALTV248300UL • ALTV248300ULCB
- 24VAC @ 12.5A (300VA) - 24VAC @ 12.5A (300VA)
or 28VAC @ 10A (280VA). or 28VAC @ 10A (280VA).
- Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.
• ALTV248300ULM • ALTV248300ULCBM
- 24VAC @ 12.5A (300VA) - 24VAC @ 12.5A (300VA)
or 28VAC @ 10A (280VA). or 28VAC @ 10A (280VA).
- Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.
• ALTV248600UL • ALTV248600ULCB
- 24VAC @ 25A (600VA) - 24VAC @ 25A (600VA)
or 28VAC @ 20A (560VA). or 28VAC @ 20A (560VA)
- Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.
Rev. 040506
Overview:
ALTV248UL Series CCTV Power Supplies provide 24VAC or 28VAC distributed via eight (8) fuse or PTC protected
outputs for powering CCTV cameras, heaters, and other video accessories.
Eight (8) Output ALTV248UL Series Reference Chart:
Altronix
Model Number
Output Voltage
Total Output Current
(Power)
Number of Outputs
PTC Protected Outputs
(Class 2 Rated power-
limited for Dry locations,
Class 3 for Wet locations)
Fuse Protected
Class 1 Outputs
Individual Output Current
(max per output, not to
exceed total output current)
Fuse Ratings
Main Fuse Ratings
Primary In-line Fuse
Ratings
115VAC 60Hz
Input Current
Agency
Listings
ALTV248UL
ALTV248ULCB
ALTV248175UL
ALTV248175ULCB
ALTV248300UL
ALTV248300ULCB
ALTV248300ULM
24VAC 3.5A
28VAC 3A
24VAC 3.5A
28VAC 3A
24VAC 7A
28VAC 6.25A
24VAC 7A
28VAC 6.25A
24VAC 12.5A
28VAC 10A
24VAC 12.5A
28VAC 10A
24VAC 12.5A
28VAC 10A
8 ---
8
8 ---
8
8 ---
8
8 ---
P
P
P
P
3.5A 3.5A
--- 2.5A ---
P
3.5A 3.5A
--- 2.5A ---
P
3.5A 3.5A
--- 2.5A ---
P
3.5A 3.5A
5A/
250V
5A/
250V
10A/
250V
10A/
250V
15A/
32V
15A/
32V
15A/
32V
3.5A/
250V
3.5A/
250V
3.5A/
250V
3.5A/
250V
1.76A
1.76A
--- 2.7A
--- 2.7A
0.9A
0.9A
2.7A
ALTV248300ULCBM
ALTV248600UL
ALTV248600ULCB
24VAC 12.5A
28VAC 10A
24VAC 25A
28VAC 20A
24VAC 25A
28VAC 20A
8
8 ---
8
P
P
--- 2.5A ---
P
3.5A 3.5A
--- 2.5A ---
15A/
32V
15A/
32V
15A/
32V
--- 2.7A
--- 5.4A
--- 5.4A
- 2 - ALTV248ULseries
Specifications:
Agency Listings:
• UL Listed for Commercial CCTV Equipment (UL 2044).
CUL Listed - CSA Standard C22.2 No.1-98, Audio,
Video and Similar Equipment.
• CE European Conformity
Input:
• 115VAC, 50/60Hz.
Output:
• Eight (8) fuse protected outputs.
• 24VAC or 28VAC output
• Outputs are rated @ 3.5A (fused) or 2.5A (PTC).
• Surge suppression.
Features:
• AC power LED indicator.
• Power ON/OFF switch (ALTV248UL, ALTV248ULCB).
Features (cont’d):
• Illuminated power disconnect circuit breaker
with manual reset (all other models).
• Unit maintains camera synchronization.
• Ease of installation saves time and eliminates costly labor.
• Spare fuses included (on fuse protected models).
Enclosure Dimensions (H x W x D):
• ALTV248UL and ALTV248ULCB:
8.5” x 7.5” x 3.5” (215.9mm x 190.5mm x 88.9mm)
• ALTV248300ULM and ALTV248300ULCBM:
8.5” x 7.5” x 3.75” (215.9mm x 190.5mm x 97.9mm).
• ALTV248175UL, ALTV248175ULCB,
ALTV248300UL and ALTV248300ULCB:
12” x 7.5” x 4.5” (304.8mm x 190.5mm x 114.3mm).
• ALTV248600UL and ALTV248600ULCB:
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.55mm).
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI, and with all local
codes and authorities having jurisdiction. Product is intended for indoor use only.
1. Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the
enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s
upper keyholes over the two upper screws, level and secure. Mark the position of the lower two holes. Remove the
enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s upper keyholes over the two
upper screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 11, 12).
Secure enclosure to earth ground.
2. Set power switch on power distribution board marked [PD] to OFF position for models ALTV248UL or
ALTV248ULCB (Figs. 1a, 2a, pg. 5). Set power disconnect circuit breaker to OFF position for all
other models (Figs. 3a-10a, pgs. 6-10).
3. All units are factory set for 24VAC operation.
For 28VAC operation adjust unit prior to mounting and applying power as follows:
Change the wire position so that the wire marked [28V] is connected to the terminal marked [P] and
the wire marked [24V] is connected to the terminal marked [S].
Note: ALTV248ULCB set for 28VAC operation is not Class 2 Rated, not power-limited.
4. Connect AC power to the black and white flying leads of the transformer(s) (Figs. 1-10, pgs. 5-10),
secure green lead to earth ground. Use 18 AWG or larger for all power connections.
Keep power-limited (PTC protected outputs only) wiring separate from non power-limited wiring.
Minimum 0.25” spacing must be provided. Use separate knockouts.
5. Set power switch on power distribution board marked [PD] to ON position for models ALTV248UL or
ALTV248ULCB (Figs. 1a, 2a, pg. 5). Set power disconnect circuit breaker to RESET (ON) position for
all other models (Figs. 3a-10a, pgs. 6-10).
6. Measure output voltage before connecting devices. This helps avoiding potential damage.
Terminals marked [1P - 8P] are of the same polarity.
CAUTION: Determine the maximum operating voltage of the equipment being powered before adjusting
the output voltage.
7. Set power switch on power distribution board marked [PD] to OFF position for models ALTV248UL or
ALTV248ULCB (Figs. 1a, 2a, pg. 5). Set power disconnect circuit breaker to OFF position for all
other models (Figs. 3a-10a, pgs. 6-10).
8. Connect devices to terminals marked [1P - 1N] through [4P - 4N] on PD4/PD4CB board (Figs. 9, 10, pgs. 9, 10)
or terminals marked [1P - 1N] through [8P - 8N] on PD8/PD8CB board (Figs. 1-8, pgs. 5-8), carefully
observing polarity.
9. Set power switch on power distribution board marked [PD] to ON position for models ALTV248UL or
ALTV248ULCB (Figs. 1a, 2a, pg. 5). Set power disconnect circuit breaker to RESET (ON) position for
all other models (Figs. 3a-10a , pgs. 6-10).
10. Green LED will illuminate when power is present.
11. Upon completion of wiring, secure enclosure door with screws (supplied). Installation of cam lock is optional.
Caution: Equipment to be installed/serviced by authorized/trained personnel only.
Shut branch circuit power before installing/servicing equipment.
ALTV248ULseries - 3 -
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This
installation should be made by qualified service personnel and should conform to the National Electrical
Code and all local codes. Use 75º C or higher rated UL insulated wiring for connecting the unit to the
mains. Replace fuses with the same type and rating (Eight (8) Output ALTV248UL Reference Chart, pg. 2).
Terminal Identification:
PD4 - Power Distribution Module
Terminal Legend Function/Description
1P - 4P AC output
1N - 4N AC output
PD8 - Power Distribution Module
Terminal Legend Function/Description
1P - 8P AC output
1N - 8N AC output
The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the
presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of
sufficient magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open enclosure. There are no
user serviceable parts inside. Refer servicing to qualified service personnel.
- 4 - ALTV248ULseries