Alto-Shaam HFT2SYS-400, HFT2SYS-300, HFT2-300, HFT2SYS-500, HFT2-500 User Manual

...
US A/CA NA DA
U.S.A. O NL Y
Hot Food Table
Merchandiser
Models:
HFT2SYS-300 HFT2-300
HFT2SYS-400 (Standard)
HFT2-300
•InstallatIon
•operatIon
HFT2SYS-400 HFT2-400
HFT2SYS-500 HFT2-500
HFT2SYS-500 (Deluxe)
W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 USA
PHONE: 262.251.3800 • 800.558.8744
•MaIntenance
www.alto-shaam.com
FAX: 262.251.7067 • 800.329.8744
M N-2 95 06 • 0 1/ 12
Delivery ...................................... 1
Unpacking .................................... 1
Safety Procedures and Precautions ................. 2
Sanitation
Sanitation/Food Safety ....................... 15
Internal Food Product Temperatures ............. 15
Installation
Installation Requirements ...................... 3
Leveling ................................... 3
Dimension Drawings, weights & capacities ........4-8
Options and Accessories ....................... 8
Electrical Specifications .......................9
Operating Instructions
User Safety Information. . . . . . . . . . . . . . . . . . . . . . . 10
Start-up Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Operating Procedures ........................ 11
General Holding Guidelines .................... 12
Care and Cleaning
Cleaning and Preventative Maintenance .......... 13
Protecting Stainless Steel Surfaces .............. 13
Cleaning Agents ............................ 13
Cleaning Materials .......................... 13
Equipment Care ............................ 14
Clean Daily ................................ 14
Service
Service View & Parts Lists
Lexan Guards .............................. 16
Tray Slides ................................ 16
Panel Colors, Deluxe Parts .................... 18
Core Unit ...............................18-19
Base ...................................20-21
Cable Heating Replacement Kits ................ 21
Calibration ................................. 21
Wire Diagrams
Always refer to the wire diagram(s) included with the unit for most current version.
Warranty
Transportation Damage and Claims ...... Back Cover
Limited Warranty ..................... Back Cover
DELIVERY
UNPACKING
This Alto-Shaam appliance has been thoroughly tested and inspected to ensure only the highest quality unit is provided. Upon receipt, check for any possible shipping damage and report it at once to the delivering carrier.
See Transportation Damage and Claims section
located in this manual.
This appliance, complete with unattached items and accessories, may have been delivered in one or more packages. Check to ensure that all standard items and options have been received with each model as ordered. Save all the information and instructions packed with the appliance. Complete and return the warranty card to the factory as soon as possible to ensure prompt service in the event of a warranty parts and labor claim. This manual must be read and understood by all people using or installing the equipment model. Contact the Alto-Shaam Tech Team Service Department if you have any questions concerning installation, operation, or maintenance.
NOTE: All claims for warranty must include the
full model number and serial number of the unit.
1. Carefully remove the appliance from the carton or crate.
®
NOTE: Do not discard the
carton and other packaging material until you have inspected the unit for hidden damage and tested it for proper operation.
2. Read all instructions in this manual carefully before initiating the installation of this appliance.
DO NOT DISCARD THIS MANUAL.
This manual is considered to be part of the appliance and is to be provided to the owner or manager of the business or to the person responsible for training operators. Additional
manuals are available from the Alto-Shaam
Tech Team Service Department.
3. Remove all protective plastic film, packaging materials, and accessories from the appliance before connecting electrical power. Store any accessories in a convenient place for future use.
®
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 1.
SAFETY PROCEDURES
AND PRECAUTIONS
Knowledge of proper procedures is essential to the safe operation of electrically and/or gas energized equipment. In accordance with generally accepted product safety labeling guidelines for potential hazards, the following signal words and symbols may be used throughout this manual.
DANGER
Used to indicate the presence of a hazard that WILL cause severe personal injury, death, or substantial property damage if the warning included with this symbol is ignored.
WARNING
Used to indicate the presence of a hazard that CAN cause personal injury, possible death, or major property damage if the warning included with this symbol is ignored.
1. This appliance is intended to hold foods for the purpose of human consumption. No other use for this appliance is authorized or recommended.
2. This appliance is intended for use in commercial establishments where all operators are familiar with the purpose, limitations, and associated hazards of this appliance. Operating instructions and warnings must be read and understood by all operators and users.
3. Any troubleshooting guides, component views, and parts lists included in this manual are for general reference only and are intended for use by qualified technical personnel.
4. This manual should be considered a permanent
part of this appliance. This manual and all supplied instructions, diagrams, schematics, parts lists, notices, and labels must remain with the appliance if the item is sold or moved to another location.
CAUTION
Used to indicate the presence of a hazard that can or will cause minor or moderate personal injury or property damage if the warning included with this symbol is ignored.
CAUTION
Used to indicate the presence of a hazard that can or will cause minor personal injury, property damage, or a potential unsafe practice if the warning included with this symbol is ignored.
NOTE: Used to notify personnel of
installation, operation, or maintenance information that is important but not hazard related.
NOTE
For equipment delivered for use in any location regulated by the following directive:
DO NOT DISPOSE OF ELECTRICAL OR ELECTRONIC EQUIPMENT WITH OTHER MUNICIPAL WASTE.
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 2.
SITE INSTALLATION
INSTALLATION
DANGER
IMPROPER INSTALLATION, ALTERATION, ADJUSTMENT, SERVICE, OR MAINTENANCE COULD RESULT IN SEVERE INJURY, DEATH, OR CAUSE PROPERTY DAMAGE.
READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
CAUTION
METAL PARTS OF THIS EQUIPMENT BECOME EXTREMELY HOT WHEN IN OPERATION. TO AVOID BURNS, ALWAYS USE HAND PROTECTION WHEN OPERATING THIS APPLIANCE.
SITE INSTALLATION
CAUTION
TO PREVENT PERSONAL INJURY,
USE CAUTION WHEN MOVING OR
LEVELING THIS APPLIANCE.
CAUTION
The performance of this unit has been optimized using the factory provided bulbs. These bulbs should be replaced with an exact replacement or with a factory recommended replacement. These bulbs have been treated to resist breakage and must be replaced with similarly treated bulbs in order to maintain compliance with NSF standards. DO NOT over-tighten bulbs in their receptacles as this can cause damage to the bulb fi lament.
In order to maintain established National Sanitation Foundation standards, all stationary floor models must be sealed to the floor with a R.T.V. or silastic meeting N.S.F. requirements or have 6" (153mm) unobstructed clearance beneath the unit.
1. The appliance must be installed on a stable and level surface.
2. DO NOT install this appliance in any area where it may be affected by any adverse conditions such as steam, grease, dripping water, high temperatures, or any other severely adverse conditions.
3. DO NOT install a heated display case near a cold air source such as a freezer, air conditioning vents, or in any area where outside air fluctuation can affect performance.
4. This appliance must be kept free and clear of any obstructions blocking access for maintenance or service.
®
A number of adjustments are associated with initial installation and start-up. It is important that these adjustments be conducted by a qualified service technician. Installation and start-up adjustments are the responsibility of the dealer or user. These adjustments include but are not limited to thermostat calibration, door adjustment, leveling, electrical hook-up and installation of optional casters or legs.
LEVELING
Level the appliance from side-to-side and front-to-back with the use of a spirit level.
We recommend checking the level periodically to make certain the floor has not shifted nor the appliance moved.
NOTE: Failure to properly level this appliance
can cause improper function.
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 3.
SITE INSTALLATION
12-1/2"
(318mm)
Top Surface
47-1/2" (1208mm)
Top Surface
38" (964mm)
Well
TOP VIEW
48" (1220mm)
1-5/16" (34mm)
12-1/2" (318mm)
Top Surface
19-13/16"
(504mm)
TOP VIEW
20-1/8"
HFT2-300
INSTALLATION
6-13/16" (173mm)
Tray Slide
33-3/4" (857mm)
4-1/8"
(104mm)
To Elec.
HFT2SYS-300 (Standard)
60-1/2" (1536mm)
42-5/8" (1081mm)
48" (1220mm)
HFT2SYS-300 (Deluxe)
43-13/16" (1113mm)
48" (1220mm)
23-1/2"
(598mm)
9-13/16" (248mm)
Reach
12-3/4" (322mm)
Lower Sales Area
7" (178mm)
Opening
39-3/4" (1008mm)
20-1/8"
(512mm)
Well
20-1/8"
(509mm)
26-1/8"
(663mm)
4"
(102mm)
12-3/4"
Opening
(322mm)
13" (331mm)
To Elec.
4-7/16" (111mm)
9-1/4" (233mm)
Shelf Width
8" (203mm) Shelf Width
20-1/8" (512mm)
20-1/8" (509mm)
26-1/8" (663mm)
39-3/4" (1008mm)
9-13/16"
(248mm)
To Well
Well
4-7/16" (111mm)
1-5/16" (34mm)
Well
Top Surface
12-1/2" (318mm)
TOP VIEW
(504mm)
19-13/16"
48" (1220mm)
39-3/4" (1008mm)
60-1/2" (1536mm)
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 4.
10-1/2" (267mm) Shelf Width
To Well Surface
37-1/8" (943mm)
67" (1701mm)
42-5/8" (1081mm)
49-1/16" (1246mm)
9"
(228mm)
60-1/2" (1536mm)
INSTALLATION
38" (964mm)
Well
34-5/16" (872mm)
20-3/16" (513mm)
Well Depth
SITE INSTALLATION
HFT2-300 (230V, International, with Bumper)
34-3/8" (872mm)
4-1/8"
(105mm)
To Elec.
48" (1220mm)
34-5/16" (872mm)
4"
38" (964mm)
Well
29-3/4" (756mm)
(102mm)
Opening
12-11/16" (322mm)
7/8"
(21mm)
13" (331mm)
To Elec.
Well Depth
20-3/16" (513mm)
4-7/16"
(111mm)
Well
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 5.
SITE INSTALLATION
12-1/2" (318mm)
Top Surface
59-1/2" (1512mm)
Top Surface
51" (1296mm)
Well
TOP VIEW
59-7/16" (1509mm)
TOP VIEW
12-1/2" (318mm)
Top Surface
39-3/4" (1008mm)
60-1/2" (1536mm)
12-3/4" (322mm)
61-1/16" (1551mm)
HFT2-400
INSTALLATION
12-3/4"
Opening
(322mm)
HFT2SYS-400 (Standard)
HFT2SYS-400 (Deluxe)
33-3/4" (857mm)
4-1/8" (104mm) To Elec.
54-5/8" (1386mm)
60" (1525mm)
27-15/16" (709mm)
23-1/2"
(598mm)
39-3/4" (1008mm)
60" (1525mm)
9-13/16" (248mm)
Reach
Lower Sales Area
27-15/16" (709mm)
Opening
7" (178mm)
4"
(102mm)
20-1/8"
(512mm)
Well
20-1/8"
(509mm)
26-1/8"
(663mm)
39-3/4" (1008mm)
9-13/16" (248mm)
To Well
13" (331mm)
To Elec.
9-1/4" (233mm)
Shelf Width
8" (203mm)
Shelf Width
79-1/8" (2009mm)
20-1/8" (509mm)
26-1/8" (663mm)
39-3/4" (1008mm)
Well
4-7/16" (111mm)
20-1/8"
(512mm)
39-3/4" (1008mm)
6-13/16" (173mm)
Tray Slide
Well
4-7/16" (111mm)
TOP VIEW
59-7/16" (1509mm)
Top Surface
12-1/2" (318mm)
60-1/2" (1536mm)
10-1/2" (267mm) Shelf Width
To Well Surface
37-1/8" (943mm)
54-5/8" (1386mm)
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 6.
9"
(228mm)
60-1/2" (1536mm)
Loading...
+ 18 hidden pages