SAFETY PROCEDURES AND PRECAUTIONS
Knowledge of proper procedures is essential to the safe operation of electrically energized equipment. In accordance with generally accepted product safety labeling guidelines for potential hazards, the following signal words and symbols may be used throughout this manual.
Used to indicate the presence of a hazard that will cause severe personal injury, death, or substantial property damage if the warning included with this symbol is ignored.
Used to indicate the presence of a hazard that can cause personal injury, possible death, or major property damage if the warning included with this symbol is ignored.
Used to indicate the presence of a hazard that can or will cause minor or moderate personal injury or property damage if the warning included with this symbol is ignored.
Used to indicate the presence of a hazard that can or will cause minor personal injury, property damage, or a potential unsafe practice if the warning included with this symbol is ignored.
Used to notify personnel of installation, operation, or maintenance information that is important but not hazard related.
1. This appliance is intended to cook, hold or process foods for the purpose of human consumption. No other use for this appliance is authorized or recommended.
2. This appliance is intended for use in commercial establishments where all operators are familiar with the purpose, limitations, and associated hazards of this appliance. Operating instructions and warnings must be read and understood by all operators and users.
3. Any troubleshooting guides, component views, and parts lists included in this manual are for general reference only and are intended for use by qualified technical personnel.
4. This manual should be considered a permanent part of this appliance. This manual and all supplied instructions, diagrams, schematics, parts lists, notices, and labels must remain with the appliance if the item is sold or moved to another location.
NOTE:
PG. 2 #825/33/37 INSTALLATION/OPERATION/SERVICE MANUAL
DELIVERY
This Alto-Shaam appliance has been thoroughly tested and inspected to insure only the highest quality unit is provided. Upon receipt, check for any possible shipping damage and report it at once to the delivering carrier. See
Transportation Damage and Claims section
located in this manual.
This appliance, complete with unattached items and accessories, may have been delivered in one or more packages. Check to ensure that all standard items and options have been received with each model as ordered.
Save all the information and instructions packed with the appliance. Complete and return the warranty card to the factory as soon as possible to assure prompt service in the event of a warranty parts and labor claim.
This manual must be read and understood by all people using or installing the equipment model. Contact the Alto-Shaam service department if you have any questions concerning installation, operation, or maintenance.
NOTE: All claims for warranty must include the
full model number and serial number of the unit.
UNPACKING
1. Carefully remove the appliance from the carton or crate.
NOTE: Do not discard the
carton and other packaging material until you have inspected the unit for hidden damage and tested it for proper operation.
2. Read all instructions in this manual carefully before initiating the installation of this appliance.
DO NOT DISCARD THIS MANUAL.
This manual is considered to be part of the appliance and is to be provided to the owner or manager of the business or to the person responsible for training operators. Additional
manuals are available from the Alto-Shaam
service department.
3. Remove all protective plastic film, packaging materials, and accessories from the appliance before connecting electrical power. Store any accessories in a convenient place for future use.
®
®
ALTO-SHAAM COOK & HOLD OVENS
OPTIONS AND ACCESSORIES ITEM
Bumper Corner Guards (SET OF FOUR)..........5221
Carving Holders
Prime Rib Holder................................HL-2635
Ship Round Holder ...................................4459
Casters, 5" (127mm) ......................................4007
Door Lock with Key .............................LK-22567
Drip Pan, Extra Deep
1000-TH-II only .........................................1115
Full Perimeter Bumper
1000-TH-II/Split, 1000-TH-II.......................4994
ITEM
Legs, 6" (152mm) ..............................................5205
Security Panel & Key Lock
500-TH-II .......................................................4366
750-TH-II (with slab door) ...........................4367
750-TH-II/D (with window door)............ 14374
1000-TH-II .....................................................4368
Shelf, Stainless Steel Rib Rack
750-TH-II.................................................SH-2743
1000-TH-II/SPLIT ..................................SH-2773
Stacking Hardware.....................................5001359
#825/33/37 INSTALLATION/OPERATION/SERVICE MANUAL PG. 3
SITE INSTALLATION
The Alto-Shaam cook and hold oven must be installed in a location that will permit the oven to function for its intended purpose and to allow adequate clearance for ventilation, proper cleaning, and maintenance access.
1. The oven must be installed on a stable and level surface.
2. DO NOT install this oven in any area where it may be affected by any adverse conditions such as steam, grease, dripping water, high temperatures, etc.
3. DO NOT store or use any flammable liquids or allow flammable vapors in the vicinity of this oven or any other appliance.
4. This appliance must be kept free and clear of any combustible materials.
5. This appliance must be kept free and clear of any obstructions blocking access for maintenance or service.
®
TO PREVENT PERSONAL INJURY, USE CAUTION WHEN MOVING OR LEVELING THIS APPLIANCE.
METAL PARTS OF THIS EQUIPMENT BECOME EXTREMELY HOT WHEN IN OPERATION. TO AVOID BURNS, ALWAYS USE HAND PROTECTION WHEN OPERATING THIS APPLIANCE.
DO NOT store or use any flammable liquids or allow flammable vapors in the vicinity of any appliance.
IMPROPER INSTALLATION, ALTERATION, ADJUSTMENT, SERVICE OR MAINTENANCE COULD RESULT IN SEVERE INJURY, DEATH OR CAUSE PROPERTY DAMAGE.
INSTALLATION
MINIMUM CLEARANCE REQUIREMENTS
COMBUSTIBLE NON-COMBUSTIBLE
SURFACES SURFACES
BACK 3" (76mm) 3" (76mm)
LEFT SIDE 1" (25mm) 1" (25mm)
RIGHT SIDE 1" (25mm) 1" (25mm)
TOP 2" (51mm) 2" (51mm)
Emissions testing conducted by Underwriters Laboratories, Inc.® was found to be in compliance with the applicable requirements of NFPA96: 2004 Edition, Par. 4.1.1.2. U.L emissions sampling of grease laden vapor resulted in a total of 0.55 milligrams per cubic meter with no visible smoke and is considered representative of all oven models in the line. Based on these results, hood installation and/or outside venting should not be a requirement in most areas. Verify local codes for locations where more restrictive codes are applicable.
PG. 4 #825/33/37 INSTALLATION/OPERATION/SERVICE MANUAL
SITE INSTALLATION
INSTALLATION
23-1/4"
(591mm)
25-7/8"
(657mm)
17-1/2"
(445mm)
27-3/8"
(695mm)
3-1/8"
(79mm)
ADD:
ELECT.
CONN.
ALTO-SHAAM
C
L
6" (152mm) For Casters or Legs
40-3/4"
(1035mm)
C
L
ELECTRICAL
CONNECTION
2-5/8"
(67mm)
25-3/8"(645mm)
28-1/4"
(718mm)
30-7/8"
(784mm)
53-3/4"
(1365mm)
2-5/8"
(67mm)
24-1/4"
(616mm)
ALTO-
SHAAM
ELECTRICAL CONNECTION
6"(152mm) FOR CASTERS
C
L
ELECTRICAL
CONNECTION
3-1/8"(79mm)
FROM TOP
27-3/8"
(695mm)
22-1/4"
(565mm)
28-1/4" (718mm)
31-3/8"
(797mm)
3
-1/8" (79mm)
50-1/2"
(1283mm)
C
L
ELECTRICAL CONNECTION 3-1/8" (79mm)
FROM TOP
34-3/8"
(873mm)
6" (152mm)
FOR CASTERS
2-5/8"
22-1/4"
(565mm)
31-1/4"
(794mm)
69"
(1753mm)
34-3/8"
(873mm)
75"
(1905mm)
ELECTRICAL
CONNECTION
C
L
(67mm)
500-TH-II
40 lb max.
Capacity
750-TH-II
100 lb max.
Capacity
1000-TH-II/SPLIT
120 lb max.
Capacity
1000-TH-II
120 lb max.
Capacity per Compartment
WEIGHT
500-TH-II 500-TH-II/D 750-TH-II 750-TH-II/D 1000-TH-II-SPLIT 1000-TH-II/D-SPLIT
NET 139 lb (63 kg) 141 lb (65 kg) 195 lb (89 kg) 205 lb (93 kg) 225 lb (102 kg) 232 lb (105 kg) SHIP 150 lb (68 kg) 155 lb (70 kg) 225 lb (102 kg) 235 lb (107 kg) 230 lb (104 kg) 235 lb (107 kg)
#825/33/37 INSTALLATION/OPERATION/SERVICE MANUAL PG. 5
SITE INSTALLATION
INSTALLATION
A number of adjustments are associated with initial installation and start-up. It is important that these adjustments be conducted by a qualified service technician. Installation and start-up adjustments are the responsibility of the dealer or user. These adjustments include but are not limited to thermostat calibration, door adjustment, leveling, electrical hook-up and installation of optional casters or legs.
LEVELING
Level the oven from side-to-side and back-to­back with the use of a spirit level. For ovens installed with casters, it is important that the installation surface be level due to the probability of frequent oven repositioning.
We recommend checking the level of the oven periodically to make certain the floor has not shifted nor the oven moved.
NOTE: Failure to properly level this oven can
cause improper function and will result in the uneven baking with products consisting of semi-liquid batter.
RESTRAINT REQUIREMENTS —MOBILE EQUIPMENT
Any appliance that is not furnished with a power supply cord but that includes a set of casters must be installed with a tether. Adequate means must be provided to limit the movement of this appliance without depending on or transmitting stress to the electrical conduit. The following requirements apply:
1. Casters must be a maximum height of 6" (152mm).
2. Two of the casters must of be the locking type.
3. Such mobile appliances or appliances on mobile
stands must be installed with the use of a flexible connector secured to the building structure.
A mounting connector for a restraining device is located on the lower back flange of the appliance chassis or on an oven stand, approximately 18" (457mm) from the floor. A flexible connector is not supplied by nor is it available from the factory.
RISK OF ELECTRIC SHOCK.
Appliance must be secured
to building structure.
WHEN MOUNTING DRIP TRAY,
SEAL DRIP TRAY HOLDER TO
UNIT WITH AN R.T.V. SEALANT
DRIP TRAY
DRIP TRAY HOLDER
EXTRA LARGE DRIP PAN [Optional]
DRIP TRAY MOUNTING INSTRUCTIONS
MODELS:
W164 N9221 Water Street P. O. Box 450
Menomonee Falls, Wisconsin 53052-0450
#243B 3/88
LOW TEMPERATURE
COOKING & HOLDING OVENS
500-TH
750-TH/II 767-SK 1000-TH-I
1000-TH-II
1000-TH 1000-TH-III = A/S PN: 1115
Bottom of Extra Large Drip Pan is positioned on the bottom (lowest) side-rack position, just above the Standard Drip Pan.
See individual model service manual, views
and parts lists, for Alto-Shaam part numbers.
[Bottom of oven interior Below side-racks]
STANDARD DRIP PAN
®
®
3: 32 x 1/2" SCREWS
[A/S PN: SC-2425]
PG. 6 #825/33/37 INSTALLATION/OPERATION/SERVICE MANUAL
INSTALLATION
SITE INSTALLATION
INSTALLATION
FAILURE TO PROPERLY INSTALL THE DRIP TRAY CAN OR WILL CAUSE MAJOR EQUIPMENT DAMAGE AND WILL RESULT IN A LEAKAGE HAZARD THAT CAN CAUSE PERSONAL INJURY.
#825/33/37 INSTALLATION/OPERATION/SERVICE MANUAL PG. 7
The appliance must be installed by a qualified service technician. The oven must be properly grounded in accordance with the National Electrical Code and applicable local codes.
Plug the unit into a properly grounded receptacle ONLY, positioning the unit so that the plug is easily accessible in case of an emergency. Arcing will occur when connecting or disconnecting the unit unless all controls are in the OFF position.
Proper receptacle or outlet configuration or permanent wiring for this unit must be installed by a licensed electrician in accordance with applicable local electrical codes.
All 208-240V 500-TH-II models will function properly within a voltage range of 200 and 240.
750-TH-II and 1000-TH-II models at 208-240V are dual rated units with a conversion switch mounted under an access cover on the rear of the oven, near the power cord.
With the voltage conversion switch in the 200-208V (UPPER) position, the oven will function properly with a source voltage of between 200 and 208.
With the voltage conversion switch in the 220-240V (LOWER) position, the unit will function properly with a source voltage of between 220 and
240.
NOTE: ALL 208-240V units are shipped from the
factory with the voltage conversion switch
in the 220-240 position. All 125V rated units will function properly with a source voltage of between 100 and 125, 60 Hz.
The 125V rated units are provided with a cord and plug [NEMA #5-20P]. Have a licensed electrician install the proper outlet configuration as required for the unit in accordance with applicable, local electrical codes. This will assure a safe and trouble-free installation.
ELECTRICAL CONNECTION
INSTALLATION
ELECTRICAL
VOLTAGE PHASE CYCLE/HZ AMPS kW VOLTAGE PHASE CYCLE/HZ AMPS kW
at 120 1 60 16.0 1.95 at 125 1 60 16.8 2.1 at 208 60 12.5 2.2 at 208 60 14.4 3.0 at 240 60 12.5 3.0 at 240 60 14.4 2.6 at 230 50 12.0 2.75 at 230 50 10.4 2.4
To avoid electrical shock, this appliance MUST be adequately grounded in accordance with local electrical codes or, in the absence of local codes, with the current edition of the National Electrical Code ANSI/NFPA No. 70. In Canada, all electrical connections are to be made in accordance with CSA C22.1, Canadian Electrical Code Part 1 or local codes.
Ensure that the voltage conversion switch position
and the available power source match.
500-TH-II
750-TH-II
1000-TH-II
ELECTRICAL CONNECTIONS MUST BE MADE BY A QUALIFIED SERVICE TECHNICIAN IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES.
PG. 8 #825/33/37 INSTALLATION/OPERATION/SERVICE MANUAL
OPERATING INSTRUCTIONS
USER SAFETY INFORMATION
The Alto-Shaam cook and hold oven is intended for use in commercial establishments by qualified operating personnel where all operators are familiar with the purpose, limitations, and associated hazards of this appliance. Operating instructions and warnings must be read and understood by all operators and users.
START-UP OPERATION
BEFORE INITIAL USE:
Interior oven surfaces must be heated to remove surface oils and the accompanying odor produced during the first use of the oven.
1. Wipe all wire shelves, side racks and the full oven interior with a clean, damp cloth. Install the oven side racks, oven shelves, and external drip tray. Shelves are installed with the curved edge toward the back of the oven. Insert the drip pan on the interior bottom surface of the oven.
2. Close the oven doors, press the power switch to the on position, and set the thermostat to 300°F (149°C).
3. Allow the oven to cycle for approximately 2 hours or until no odor is detected.
PREHEATING:
Always preheat the oven for a minimum of 20 minutes before cooking product. Follow the operating instructions indicated on the next page of this manual.
Metal parts of this equipment become extremely hot when in operation. To avoid burns, always use hand protection when operating this oven.
AT NO TIME SHOULD THE INTERIOR OR EXTERIOR BE STEAM CLEANED, HOSED DOWN, OR FLOODED WITH WATER OR LIQUID SOLUTION OF ANY KIND.
DO NOT USE WATER JET TO CLEAN.
SEVERE DAMAGE OR ELECTRICAL HAZARD COULD RESULT.
WARRANTY BECOMES VOID IF APPLIANCE IS FLOODED.