This Alto-Shaam appliance has been thoroughly tested and inspected to insure only the highest quality unit is provided. Upon receipt, check for any possible shipping damage and report it at once to the delivering carrier. See
Transportation Damage and Claims section
located in this man ual.
This appliance, complete with unattached items and accessories, may have been delivered in one or more packages. Check to ensure that all standard items and options have been received with each model as ordered.
Save all the information and instructions packed with the appliance. Complete and return the warranty card to the factory as soon as possible to assure prompt service in the event of a warranty parts and labor claim.
This manual must be read and understood by all people using or installing the equipment model. Contact the Alto-Shaam service department if you have any questions concerning installation, operation, or maintenance.
N O T E : All claims for warranty must include the
full model number and serial number of the unit.
U N P A C K I N G
1. Carefully remove the appliance from the carton or crate.
N O T E : Do not discard the
carton and other packaging material until you have inspected the unit for hidden damage and tested it for proper operation.
2. Read all instructions in this manual carefully before initiating the installation of this appliance.
DO NOT DISCARD THIS MANUAL. This manual is considered to be part of the appliance and is to be provided to the owner or manager of the business or to the person responsible for training operators. Additional
manuals are available fr om the Alto-Shaam
service department.
3. Remove all protective plastic film, packaging materials, and accessories from the appliance before connecting electrical power. Store any accessories in a convenient place for future use.
®
®
®
TH /II I IN S TA L LA T ION /OP E RA T IO N /SE R VI C E MA NU A L PG . 1
1. This appliance is intended to cook, hold or
process foods for the purpose of human consumption. No other use for this appliance is authorized or recommended.
2. This appliance is intended for use in commercial
establishments where all operators are familiar with the purpose, limitations, and associated hazards of this appliance. Operating instructions and warnings must be read and understood by all operators and users.
3. Any troubleshooting guides, component views,
and parts lists included in this manual are for general reference only and are intended for use by qualified technical personnel.
4. This manual should be considered a permanent
part of this appliance. This manual and all supplied instructions, diagrams, schematics, parts lists, notices, and labels must remain with the appliance if the item is sold or moved to another location.
N O T E : Used to notify personnel of
installation, operation, or maintenance information that is important but not hazard related.
C A U T I O N
Used to indicate the presence of a hazard that can or will cause minor personal injury, property damage, or a potential unsafe practice if the warning included with this symbol is ignored.
C A U T I O N
Used to indicate the presence of a hazard that can or will cause minor or moderate personal injury or property damage if the warning included with this symbol is ignored.
D A N G E R
Used to indicate the presence of a hazard that WILL cause severe personal injury, death, or substantial property damage if the warning included with this symbol is ignored.
W A R N I N G
Used to indicate the presence of a hazard that CAN cause personal injury, possible death, or major property damage if the warning included with this symbol is ignored.
SAFETY PR O C EDURES AND PRE C A U T IONS
Knowledge of proper procedures is essential to the safe operation of electrically and/or gas energized equipment. In accordance with generally accepted product safety labeling guidelines for potential hazards, the following signal words and symbols may be used throughout this manual.
N O T E
For equipment delivered for use in any location regulated by the following directive:
DO NOT DISPOSE OF ELECTIRCAL OR ELECTRONIC EQUIPMENT WITH OTHER MUNICIPAL WASTE.
PG . 2 TH /II I IN S TA L LA T ION /OP E RA T IO N /SE R VI C E MA NU A L
®
I N S T A L L A T I O N
D A N G E R
IMPROPER INSTALLATION, A
LTERATION, ADJUSTMENT, SERVICE, OR MAINTENANCE COULD RESULT IN SEVERE INJURY, DEATH OR CAUSE PROPERTY DAMAGE.
READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
C A U T I O N
TO PREVENT PERSONAL INJURY,
USE CAUTION WHEN MOVING OR
LEVELING THIS APPLIANCE.
C A U T I O N
M
ETAL PARTS OF THIS EQUIPMENT BECOME EXTREMELY HOT WHEN IN OPERATION. TO AVOID BURNS, ALWAYS USE HAND PROTECTION WHEN OPERATING THIS APPLIANCE.
D A N G E R
DO NOT store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
N O T E
If the appliance has been unplugged for an extended period of time, the Real Time Clock may require recharging. Plug the unit into the proper recepta cle for a minimum of 24 hours.
The Alto-Shaam cook and hold oven must be installed in a location that will permit the oven to function for its intended purpose and to allow adequate clearance for ventilation, proper cleaning, and maintenance access.
1. The oven must be installed on a stable and level surface.
2. DO NOT install this appliance in any area where it may be affected by any adverse conditions such as steam, grease, dripping water, high temperatures, or any other severely adverse conditions.
3. DO NOT store or use any flammable liquids or allow flammable vapors in the vicinity of this oven or any other appliance.
4. This appliance must be kept free and clear of any combustible materials.
5. This appliance must be kept free and clear of any obstructions blocking access for maintenance or service.
TH /II I
IN S TA L LA T ION /OP E RA T IO N /SE R VI C E M A NUA L PG . 3
S I T E I N S T A L L A T I O N
Emissions testing conducted by Underwriters Laboratories, Inc.® was found to be in compliance with the applicable requirements of NFPA96: 2004 Edition, Par. 4.1.1.2. U.L emissions sampling of grease laden vapor resulted in a total of 0.55 milligrams per cubic meter with no visible smoke and is considered representative of all oven models in the line. Based on these results, hood installation and/or outside venting should not be a requirement in most areas. Verify local codes for locations where more restrictive codes are applicable.
MINIMUM CLEARANCE REQUIREMENTS
18" (457mm) minimum clearance at the back from heat producing equipment. To protect the electronic control, maintain sufficient side clearance to prevent the control area from reaching any temperature at or above 140°F (60°C).
I N S T A L L A T I O N
18-1/16" (458mm)
25-7/16" (646mm)
25-1/8" (638mm)
30-3/8" (772mm)
21" (532mm)
with optional bumper
43-9/16" (1106mm)
40-5/16" (1023mm)
*32-1/16" (814mm) - with optional 2-1/2" casters *34-5/16" (874mm) - with optional 5" casters *34-11/16" (880mm) - with optional 6" legs
33-1/16" (839mm)
with 3-1/2" Casters*
27-13/16" (705mm)
29-1/4" (743mm)
with optional bumper
8-15/16" (227mm)
Electrical
Connection
Electrical Connection
S I T E I N S T A L L A T I O N
500-TH/III
WEIGHT
NE T: 150 lb (68 kg) EST.
PG . 4 TH /II I IN S TA L LA T ION /OP E RA T IO N /SE R VI C E MA NU A L
SHIP: 165 lb (75 kg) E ST.
PRODU CT\ PAN C A PACITY
40 lb (18 kg)
VO L UME MA X IMU M
MA X IMU M
: 30 Q U ART S (38 LITER S)
S I T E I N S T A L L A T I O N
28-1/4" (716mm)
with optional bumper
33-3/16" (843mm)
with 3-1/2" casters*
25-3/4"
(653mm)
33-7/8" (860mm)
with optional bumper
30-15/16"
(785mm)
25-1/8" (638mm)
30-7/16" (772mm)
53-9/16" (1360mm)
55-1/2" (1408mm)
with optional bumper
77-1/2" (1967mm) - Pass-Through Option
33-5/8" (856mm)
Electrical
Connection
Pass-Through
Option
*32-3/16" (817mm) - with optional 2-1/2" casters *34-5/8" (878mm) - with optional 5" casters *34-13/16" (884mm) - with optional 6" legs
26-5/8"
(675mm)
27-7/8"
(708mm)
12-7/8"
(326mm)
Electrical
Connection
33-7/8" (860mm)
with optional bumper
Electrical Connection
750-TH/III
I N S T A L L A T I O N
WEIGHT
SHIP: 212 lb (96 kg) E ST.
NET: 192 lb (87 kg) EST.
PRODU CT\ PAN C A PACITY
TH /II I IN S TA L LA T ION /OP E RA T IO N /SE R VI C E MA NU A L PG . 5
100 lb (45 kg)
VO L UME MA X IMU M
MA X IMU M
: 75 Q U ART S (95 LITER S)
I N S T A L L A T I O N
22-5/8" (573mm)
39-7/8" (1012mm)
with Standard 3-1/2" Casters*
31-15/16" (811mm)
37-1/4" (945mm)
30-3/4" (780mm)
25-1/16" (636mm)
with optional bumper
33-7/8" (860mm)
with optional bumper
*38-7/8" (987mm) - with optional 2-1/2" casters *41-1/4" (1047mm) - with optional 5" casters *41-1/2" (1053mm) - with optional 6" legs
34-5/8" (878mm)
72-3/8" (1838mm) Pass-Through Option
53-1/8" (1349mm) with optional bumper
50-1/16" (1272mm)
11-1/4"
(284mm)
33-11/16" (856mm)
33-7/8" (860mm)
with optional bumper
Electrical
Connection
Pass-Through
Option
Electrical
Connection
S I T E I N S T A L L A T I O N
1000-TH/III
WEIGHT
NE T: 225 lb (102 kg) EST.
SHIP: 233 lb (106 kg) ES T.
PRODU CT\ PAN C A PACITY
120 lb (54 kg)
VO L UME MA X IMU M
: 60 Q U ART S (76 LITER S)
MA X IMU M
PG . 6 TH /II I IN S TA L LA T ION /OP E RA T IO N /SE R VI C E MA NU A L
S I T E I N S T A L L A T I O N
75-9/16" (1918mm) with 5" (127mm) Casters*
25-1/16" (636mm)
22-9/16" (573mm)
31-3/16" (791mm)
33-7/8" (860mm)
66-1/8" (1679mm)
72-15/16" (1852mm)
72-1/16" (1830mm)
33-3/8" (848mm)
33-7/8" (860mm)
Reach-In
Electrical Conn.
50-5/8" (1285mm)
53-1/8" (1349mm)
10-1/16" (255mm)
Electrical
Connection
Reach-In
Electrical
Connection
Pass-Through
Option
*74-3/16" (1883mm) - with optional 3-1/2" (89mm) casters
1200-TH/III
I N S T A L L A T I O N
WEIGHT
NE T: 420 lb (191 kg) EST.
SHIP: 475 lb (215 kg) EST .
PRODU CT\ PAN C A PACITY (P ER C O M P A R T M E N T )
120 lb (54 kg)
VO L UME MA X IMU M
TH /II I
IN S TA L LA T ION /OP E RA T IO N /SE R VI C E M A NUA L PG . 7
MA X IMU M
: 60 Q U ART S (76 LITER S)
I N S T A L L A T I O N
OPTIONS AN D A CCESSORIE S 500-TH/III 750-TH/III 1000-TH/III 1200-TH/III
Bumper, Full Perimeter 5006782 5004861 5005103 5005103
arving Holder,
C
RI ME R IB
ST EAM SHI P
P
(C AFE TER IA) R OUN D
HL-2635
4459
HL-2635
4459
HL-2635
4459
HL-2635
4459
Casters - 2 R
IGID
WIVEL W/BRAKE
, 2 S
5" (127mm) 3-1/2" (89mm) 2-1/2" (64mm)
5004862
ST AND ARD
5008022
5004862
ST AND ARD
5008022
5004862
ST AND ARD
5008022
TA NDA RD
S
5008017
––
Door with Window
RI GHT -HA ND
LE FT-HAN D
15855R 15857R
15433R 15732R
15879R 15881R
15879R 15881R
Door Lock with Key LK-22567 LK-22567 LK-22567 LK-22567
Drip Pan
ST AND ARD WIT H DR AIN , 1-7/16" (37mm)
ST AND ARD WIT H DR AIN , 1-11/16" (43mm)
ST AND ARD WIT H DR AIN , 1-7/8" (48mm)
EX TRA DEE P, 2-7/16" (62mm)
14813
–– –– ––
––
14831
––
1115
–– ––
14824
1115
–– ––
14824
1115
Legs, 6" (152mm), Flanged (SET O F FO UR) 5004863 5004863 5004863 5004863
Pan Grid, Wire - 18" X 26" PAN INSERT –– PN-2115 PN-2115 PN-2115
Pan Slides (230V ONLY) 5008251 5008240 –– ––
Shelf, Stainless Steel
FL AT W IRE, RE ACH-IN
FL AT W IRE, PA SS-THRO UGH
RI B RACK
SH-2326
–– ––
SH-2324 SH-2327 SH-2743
SH-2325 SH-2346 SH-2773
SH-2325 SH-2346 SH-2773
Stacking Hardware 5004864 5004864 5004864 ––
HACCP Network Options
HACCP DocumentationHACCP with Kitchen Management
* REFER TO HACCP SPECIFICATION #9015 FOR APPLICABLE PART NUMBERS.
PG . 8 TH /II I IN S TA L LA T ION /OP E RA T IO N /SE R VI C E MA NU A L
I N S T A L L A T I O N
CASTER SET SCREW
TOP MOUNTING SCREWS
STACKING POSTS
TOP MOUNTING SCREWS
STACKING INSTRUCTIONS
1
) If the two appliances were shipped together from the factory, the top unit will have the
casters already removed. A stacking kit will be included with the shipment.
If casters need to be removed: lay the unit on its back, and remove the set screw on each caster. Pull the casters out of the unit.
2) While appliance is laid on its back, insert one stacking post in each of the four corners of the upper unit. Secure the stacking posts using one screw and two flat washers that come with the stacking kit.
Note: The flange on the stacking posts must face the outside of the unit.
3) Remove the four top mounting screws from the lower unit. Place the upper appliance, which has the stacking posts installed, on top of the bottom unit. Center the top unit from front to back. Re-install the four screws through the flange of the four stacking posts.
S I T E I N S T A L L A T I O N
Stacking Configurations
1000-TH/III with 1000-TH/III or 1000-S 750-TH/III with 750-TH/III, 750-S, or 767-SK/III 500-TH/III with 500-TH/III or 500-S
TH /II I IN S TA L LA T ION /OP E RA T IO N /SE R VI C E MA NU A L PG . 9
I N S T A L L A T I O N
W A R N I N G
RISK OF ELE CTRIC S HOCK.
Appliance must be secured
to building structure.
S I T E I N S T A L L A T I O N
A number of adjustments are associated with
nitial installation and start-up. It is important
i that these adjustments be conducted by a qualified service technician. Installation and start-up adjustments are the responsibility of the dealer or user. These adjustments include but are not limited to thermostat calibration, door adjustment, leveling, electrical hook-up and installation of optional casters or legs.
LEVELING
Level the oven from side-to-side and front-to­back with the use of a spirit level. For ovens installed with casters, it is important that the installation surface be level due to the probability of frequent oven repositioning.
We recommend checking the level of the oven periodically to make certain the floor has not shifted nor the oven moved.
NOT E : Failure to properly level this oven can
cause improper function and will result in the uneven baking with products consisting of semi-liquid batter.
RESTRAINT REQUIREME NTS —MOBILE EQ UIPMENT
Any appliance that is not furnished with a power supply cord but that includes a set of casters must be installed with a tether. Adequate means must be provided to limit the movement of this appliance without depending on or transmitting stress to the electrical conduit. The following requirements apply:
1. Maximum height of casters is 6" (152mm).
2. Two of the casters must of be the locking type.
Such mobile appliances or appliances on mobile
3.
stands must be installed with the use of a flexible connector secured to the building structure.
A mounting connector for a restraining device is located on the lower back flange of the appliance chassis or on an oven stand, approximately 18" (457mm) from the floor. A flexible connector is not supplied by nor is it available from the factory.
PG . 10 TH /II I IN S TA L LA T ION /OP E RA T IO N /SE R VI C E MA NU A L
S I T E I N S T A L L A T I O N
W A R N I N G
FAIL UR E TO PROPE R LY INSTALL THE DRIP TR AY CAN OR WIL L CA US E MAJOR EQU IP ME NT DAMAGE AND WILL RE SU LT IN A LEAKAGE HAZARD TH AT CAN CAUSE PERSONAL IN JU RY.
D R I P T R AY IN S TA L L AT I O N IN S T R U C T I O N S
D R I P T R AY IN S TA L L AT I O N IN S T R U C T I O N S
STANDARD DRIP PAN*
[BOTTOM OF OVEN INTERIOR • BELOW
SIDE-RACKS]
I N S T A L L A T I O N
HANG DRIP TRAY ON SCREWS
TH /II I IN S TA L LA T ION /OP E RA T IO N /SE R VI C E MA NU A L PG . 11
DRIP TRAY*
*SEE ALTO-SHAAM PARTS LIST FOR ALTO-SHAAM PART NUMBERS.
I N S T A L L A T I O N
D A N G E R
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
D A N G E R
To avoid electrical shock, this appliance MUST be adequately grounded in accordance with local electrical codes or, in the absence of local codes, with the current edition of the National Electrical Code ANSI/NFPA No. 70. In Canada, all electrical connections are to be made in according with CSA C22.1, Canadian Electrical Code Part 1 or local codes.
D A N G E R
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
E L E C T R I C A L C O N N E C T I O N
The appliance must be installed by a qualified service technician. The oven must be properly grounded in accordance with the National
lectrical Code and applicable local codes.
E
Plug the unit into a properly grounded receptacle ONLY, positioning the unit so that the plug is easily accessible in case of an emergency. Arcing will occur when connecting or disconnecting the unit unless all controls are in the “
FF
O
” position.
Proper receptacle or outlet configuration or permanent wiring for this unit must be installed by a licensed electrician in accordance with applicable local electrical codes.
E L E C T R I C A L - 50 0 - T H / I I I
VOLTA GE PHASE CYCL E/HZ AMPS
120 1 60 16.0 1.92 N
208-240 (UL)1 60 11.2 2.70
at 208 1 60 10.6 2.20 at 240 1 60 12.2 2.93
230 1 50 12.0 2.75 CE E 7/7
kW
CORD&PLUG
EM A
20A-125
NO CO RD
&
220-230V P LU G
5-20
V
PL UG
P
PL UG
230 V :
To prevent an electrical shock hazard between the appliance and other appliances or metal
arts in close vicinity, an equalization-bonding
p stud is provided. An equalization bonding lead must be connected to this stud and the other appliances / metal parts to provide sufficient protection against potential difference. The terminal is marked with the following symbol.
NOT E : The appliance must be connected to an
electrical circuit that is protected by an external GFCI outlet.
E L E C T R I C A L - 75 0 - T H / I I I
VOLTA GE PHASE CYCL E/HZ AMPS
208-240 (UL)1 60 15.8 3.80
at 208 1 60 14.6 3.04 at 240 1 60 16.9 4.05
230 1 50 15 3.0 CE E 7/7
E L E C T R I C A L - 10 0 0 - T H / I I I
VOLTA GE PHASE CYCL E/ H Z AMP S kW CORD & P LU G
208-240 (UL)1 60 15.8 3.8
at 208 1 60 14.4 3.0 at 240 1 60 16.7 4.0
230 1 50 13.5 2.7
E L E C T R I C A L - 1 2 0 0 - T H / I I I
VOLTAGE PHASE CYCLE/ HZ AMPS kW CORD & PLUG
208-240 (UL)1 60 30 7.2
at 208 1 60 28.9 6.0
at 240 1 60 33.3 8.0
230 1 50 28.7 6.6
PG . 12 TH /II I IN S TA L LA T ION /OP E RA T IO N /SE R VI C E MA NU A L
kW
CORD&PLUG
NO CO RD
&
PL UG
220-230V P LU G
NO C ORD
& PL UG
CE E 7/7
220-230V P LU G
NO CORD
& PLUG
NO CORD & PLUG