W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 USA
PHONE: 262.251.3 800 • 800.5 58.8744
US A/C ANA D AFAX: 262.251. 7067 • 800.329 .8744 U.S.A . ON LY
www.alt o-shaam.com
®
E l e c t r o n i c C o n t r o l
Model:
500-TH /III
750-TH /III
1000-TH / III
1200-TH / III
1200-TH/III
500-TH/III
1000-TH/III
•IN STALLATION
•OPERATION
•MAI NTENANCE
750-TH/III
P R I N T E D I N U. S .A .
MN-28679 • 04/08
D E L I V E R Y
This Alto-Shaam appliance has been
thoroughly tested and inspected to insure only the
highest quality unit is provided. Upon receipt,
check for any possible shipping damage and report
it at once to the delivering carrier. See
Transportation Damage and Claims section
located in this man ual.
This appliance, complete with unattached
items and accessories, may have been delivered in
one or more packages. Check to ensure that all
standard items and options have been received
with each model as ordered.
Save all the information and instructions
packed with the appliance. Complete and return
the warranty card to the factory as soon as
possible to assure prompt service in the event of a
warranty parts and labor claim.
This manual must be read and understood by
all people using or installing the equipment
model. Contact the Alto-Shaam service
department if you have any questions concerning
installation, operation, or maintenance.
N O T E :All claims for warranty must include the
full model number and serial number of
the unit.
U N P A C K I N G
1. Carefully remove the
appliance from the
carton or crate.
N O T E : Do not discard the
carton and other
packaging material
until you have
inspected the unit
for hidden damage
and tested it for
proper operation.
2. Read all instructions in this manual carefully
before initiating the installation of this appliance.
DO NOT DISCARD THIS MANUAL.
This manual is considered to be part of the
appliance and is to be provided to the owner or
manager of the business or to the person
responsible for training operators. Additional
manuals are available fr om the Alto-Shaam
service department.
3. Remove all protective plastic film, packaging
materials, and accessories from the appliance
before connecting electrical power. Store any
accessories in a convenient place for future use.
®
®
®
TH /II I IN S TA L LA T ION /OP E RA T IO N /SE R VI C E MA NU A LPG . 1
1. This appliance is intended to cook, hold or
process foods for the purpose of human
consumption. No other use for this appliance is
authorized or recommended.
2. This appliance is intended for use in commercial
establishments where all operators are familiar
with the purpose, limitations, and associated
hazards of this appliance. Operating
instructions and warnings must be read and
understood by all operators and users.
3. Any troubleshooting guides, component views,
and parts lists included in this manual are for
general reference only and are intended for use
by qualified technical personnel.
4. This manual should be considered a permanent
part of this appliance. This manual and all
supplied instructions, diagrams, schematics,
parts lists, notices, and labels must remain with
the appliance if the item is sold or moved to
another location.
N O T E : Used to notify personnel of
installation, operation, or
maintenance information that is
important but not hazard related.
C A U T I O N
Used to indicate the presence of a hazard that can
or will cause minor personal injury, property
damage, or a potential unsafe practice if the
warning included with this symbol is ignored.
C A U T I O N
Used to indicate the presence of a
hazard that can or will cause minor or
moderate personal injury or property
damage if the warning included with
this symbol is ignored.
D A N G E R
Used to indicate the presence of a
hazard that WILL cause severe
personal injury, death, or substantial
property damage if the warning
included with this symbol is ignored.
W A R N I N G
Used to indicate the presence of a
hazard that CAN cause personal injury,
possible death, or major property
damage if the warning included with
this symbol is ignored.
SAFETY PR O C EDURES
AND PRE C A U T IONS
Knowledge of proper procedures is essential to the
safe operation of electrically and/or gas energized
equipment. In accordance with generally accepted
product safety labeling guidelines for potential
hazards, the following signal words and symbols
may be used throughout this manual.
N O T E
For equipment delivered for use
in any location regulated by the
following directive:
DO NOT DISPOSE OF ELECTIRCAL
OR ELECTRONIC EQUIPMENT WITH
OTHER MUNICIPAL WASTE.
PG . 2TH /II I IN S TA L LA T ION /OP E RA T IO N /SE R VI C E MA NU A L
®
I N S T A L L A T I O N
D A N G E R
IMPROPER INSTALLATION,
A
LTERATION, ADJUSTMENT,
SERVICE, OR MAINTENANCE COULD
RESULT IN SEVERE INJURY, DEATH
OR CAUSE PROPERTY DAMAGE.
READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING
THIS EQUIPMENT.
C A U T I O N
TO PREVENT PERSONAL INJURY,
USE CAUTION WHEN MOVING OR
LEVELING THIS APPLIANCE.
C A U T I O N
M
ETAL PARTS OF THIS EQUIPMENT
BECOME EXTREMELY HOT WHEN IN
OPERATION. TO AVOID BURNS,
ALWAYS USE HAND PROTECTION
WHEN OPERATING THIS APPLIANCE.
D A N G E R
DO NOT store or use gasoline or other
flammable vapors or liquids in the
vicinity of this or any other appliance.
N O T E
If the appliance has been unplugged for an
extended period of time, the Real Time
Clock may require recharging. Plug the unit
into the proper recepta cle for a minimum of
24 hours.
The Alto-Shaam cook
and hold oven must be
installed in a location
that will permit the
oven to function for its
intended purpose and
to allow adequate
clearance for
ventilation, proper
cleaning, and
maintenance access.
1. The oven must be installed on a stable and
level surface.
2. DO NOT install this appliance in any area
where it may be affected by any adverse
conditions such as steam, grease, dripping
water, high temperatures, or any other severely
adverse conditions.
3. DO NOT store or use any flammable liquids or
allow flammable vapors in the vicinity of this
oven or any other appliance.
4. This appliance must be kept free and clear of
any combustible materials.
5. This appliance must be kept free and clear of
any obstructions blocking access for
maintenance or service.
TH /II I
IN S TA L LA T ION /OP E RA T IO N /SE R VI C E M A NUA LPG . 3
S I T E I N S T A L L A T I O N
Emissions testing conducted by Underwriters
Laboratories, Inc.® was found to be in
compliance with the applicable requirements of
NFPA96: 2004 Edition, Par. 4.1.1.2. U.L
emissions sampling of grease laden vapor
resulted in a total of 0.55 milligrams per cubic
meter with no visible smoke and is considered
representative of all oven models in the line.
Based on these results, hood installation and/or
outside venting should not be a requirement in
most areas. Verify local codes for locations
where more restrictive codes are applicable.
MINIMUM CLEARANCE REQUIREMENTS
18" (457mm) minimum clearance at the back from heat
producing equipment. To protect the electronic
control, maintain sufficient side clearance to prevent
the control area from reaching any temperature at or
above 140°F (60°C).
I N S T A L L A T I O N
18-1/16" (458mm)
25-7/16" (646mm)
25-1/8" (638mm)
30-3/8" (772mm)
21" (532mm)
with optional bumper
43-9/16" (1106mm)
40-5/16" (1023mm)
*32-1/16" (814mm) - with optional 2-1/2" casters
*34-5/16" (874mm) - with optional 5" casters
*34-11/16" (880mm) - with optional 6" legs
33-1/16" (839mm)
with 3-1/2" Casters*
27-13/16" (705mm)
29-1/4" (743mm)
with optional bumper
8-15/16"
(227mm)
Electrical
Connection
Electrical Connection
S I T E I N S T A L L A T I O N
500-TH/III
WEIGHT
NE T: 150 lb (68 kg) EST.
PG . 4TH /II I IN S TA L LA T ION /OP E RA T IO N /SE R VI C E MA NU A L
SHIP: 165 lb (75 kg) E ST.
PRODU CT\ PAN C A PACITY
40 lb (18 kg)
VO L UME MA X IMU M
MA X IMU M
: 30 Q U ART S (38 LITER S)
S I T E I N S T A L L A T I O N
28-1/4" (716mm)
with optional bumper
33-3/16" (843mm)
with 3-1/2" casters*
25-3/4"
(653mm)
33-7/8" (860mm)
with optional bumper
30-15/16"
(785mm)
25-1/8" (638mm)
30-7/16" (772mm)
53-9/16" (1360mm)
55-1/2" (1408mm)
with optional bumper
77-1/2" (1967mm) - Pass-Through Option
33-5/8" (856mm)
Electrical
Connection
Pass-Through
Option
*32-3/16" (817mm) - with optional 2-1/2" casters
*34-5/8" (878mm) - with optional 5" casters
*34-13/16" (884mm) - with optional 6" legs
26-5/8"
(675mm)
27-7/8"
(708mm)
12-7/8"
(326mm)
Electrical
Connection
33-7/8" (860mm)
with optional bumper
Electrical Connection
750-TH/III
I N S T A L L A T I O N
WEIGHT
SHIP: 212 lb (96 kg) E ST.
NET: 192 lb (87 kg) EST.
PRODU CT\ PAN C A PACITY
TH /II I IN S TA L LA T ION /OP E RA T IO N /SE R VI C E MA NU A LPG . 5
100 lb (45 kg)
VO L UME MA X IMU M
MA X IMU M
: 75 Q U ART S (95 LITER S)
I N S T A L L A T I O N
22-5/8" (573mm)
39-7/8" (1012mm)
with Standard 3-1/2" Casters*
31-15/16" (811mm)
37-1/4" (945mm)
30-3/4" (780mm)
25-1/16" (636mm)
with optional bumper
33-7/8" (860mm)
with optional bumper
*38-7/8" (987mm) - with optional 2-1/2" casters
*41-1/4" (1047mm) - with optional 5" casters
*41-1/2" (1053mm) - with optional 6" legs
34-5/8" (878mm)
72-3/8" (1838mm) Pass-Through Option
53-1/8" (1349mm) with optional bumper
50-1/16" (1272mm)
11-1/4"
(284mm)
33-11/16" (856mm)
33-7/8" (860mm)
with optional bumper
Electrical
Connection
Pass-Through
Option
Electrical
Connection
S I T E I N S T A L L A T I O N
1000-TH/III
WEIGHT
NE T: 225 lb (102 kg) EST.
SHIP: 233 lb (106 kg) ES T.
PRODU CT\ PAN C A PACITY
120 lb (54 kg)
VO L UME MA X IMU M
: 60 Q U ART S (76 LITER S)
MA X IMU M
PG . 6TH /II I IN S TA L LA T ION /OP E RA T IO N /SE R VI C E MA NU A L
S I T E I N S T A L L A T I O N
75-9/16" (1918mm) with 5" (127mm) Casters*
25-1/16" (636mm)
22-9/16" (573mm)
31-3/16" (791mm)
33-7/8" (860mm)
66-1/8" (1679mm)
72-15/16" (1852mm)
72-1/16" (1830mm)
33-3/8" (848mm)
33-7/8" (860mm)
Reach-In
Electrical
Conn.
50-5/8" (1285mm)
53-1/8" (1349mm)
10-1/16"
(255mm)
Electrical
Connection
Reach-In
Electrical
Connection
Pass-Through
Option
*74-3/16" (1883mm) - with optional 3-1/2" (89mm) casters
1200-TH/III
I N S T A L L A T I O N
WEIGHT
NE T: 420 lb (191 kg) EST.
SHIP: 475 lb (215 kg) EST .
PRODU CT\ PAN C A PACITY (P ER C O M P A R T M E N T )
120 lb (54 kg)
VO L UME MA X IMU M
TH /II I
IN S TA L LA T ION /OP E RA T IO N /SE R VI C E M A NUA LPG . 7
MA X IMU M
: 60 Q U ART S (76 LITER S)
I N S T A L L A T I O N
OPTIONS AN D A CCESSORIE S500-TH/III750-TH/III 1000-TH/III 1200-TH/III
Bumper, Full Perimeter5006782500486150051035005103
arving Holder,
C
RI ME R IB
ST EAM SHI P
P
(C AFE TER IA) R OUN D
HL-2635
4459
HL-2635
4459
HL-2635
4459
HL-2635
4459
Casters - 2 R
IGID
WIVEL W/BRAKE
, 2 S
5" (127mm)
3-1/2" (89mm)
2-1/2" (64mm)
5004862
ST AND ARD
5008022
5004862
ST AND ARD
5008022
5004862
ST AND ARD
5008022
TA NDA RD
S
5008017
––
Door with Window
RI GHT -HA ND
LE FT-HAN D
15855R
15857R
15433R
15732R
15879R
15881R
15879R
15881R
Door Lock with KeyLK-22567LK-22567LK-22567LK-22567
Drip Pan
ST AND ARD WIT H DR AIN , 1-7/16" (37mm)
ST AND ARD WIT H DR AIN , 1-11/16" (43mm)
ST AND ARD WIT H DR AIN , 1-7/8" (48mm)
EX TRA DEE P, 2-7/16" (62mm)
14813
––
––
––
––
14831
––
1115
––
––
14824
1115
––
––
14824
1115
Legs, 6" (152mm), Flanged (SET O F FO UR)5004863500486350048635004863
Pan Grid, Wire - 18" X 26" PAN INSERT––PN-2115PN-2115PN-2115
Pan Slides (230V ONLY)50082515008240––––
Shelf, Stainless Steel
FL AT W IRE, RE ACH-IN
FL AT W IRE, PA SS-THRO UGH
RI B RACK
SH-2326
––
––
SH-2324
SH-2327
SH-2743
SH-2325
SH-2346
SH-2773
SH-2325
SH-2346
SH-2773
Stacking Hardware500486450048645004864––
HACCP Network Options
➥ HACCP Documentation
➥ HACCP with Kitchen Management
* REFER TO HACCP SPECIFICATION #9015 FOR APPLICABLE PART NUMBERS.
PG . 8TH /II I IN S TA L LA T ION /OP E RA T IO N /SE R VI C E MA NU A L
I N S T A L L A T I O N
CASTER SET SCREW
TOP
MOUNTING
SCREWS
STACKING
POSTS
TOP
MOUNTING
SCREWS
STACKING INSTRUCTIONS
1
) If the two appliances were shipped together from the factory, the top unit will have the
casters already removed. A stacking kit will be included with the shipment.
If casters need to be removed: lay the unit on its back, and remove the set screw on each caster. Pull the
casters out of the unit.
2) While appliance is laid on its back, insert one stacking post in each of the four corners of
the upper unit. Secure the stacking posts using one screw and two flat washers that come
with the stacking kit.
Note: The flange on the stacking posts must face the outside of the unit.
3) Remove the four top mounting screws from the lower unit. Place the upper appliance,
which has the stacking posts installed, on top of the bottom unit. Center the top unit from
front to back. Re-install the four screws through the flange of the four stacking posts.
S I T E I N S T A L L A T I O N
Stacking Configurations
1000-TH/III with 1000-TH/III or 1000-S
750-TH/III with 750-TH/III, 750-S, or 767-SK/III
500-TH/III with 500-TH/III or 500-S
TH /II I IN S TA L LA T ION /OP E RA T IO N /SE R VI C E MA NU A LPG . 9
I N S T A L L A T I O N
W A R N I N G
RISK OF ELE CTRIC S HOCK.
Appliance must be secured
to building structure.
S I T E I N S T A L L A T I O N
A number of adjustments are associated with
nitial installation and start-up. It is important
i
that these adjustments be conducted by a qualified
service technician. Installation and start-up
adjustments are the responsibility of the dealer or
user. These adjustments include but are not
limited to thermostat calibration, door adjustment,
leveling, electrical hook-up and installation of
optional casters or legs.
LEVELING
Level the oven
from side-to-side and front-toback with the use of a spirit level. For ovens
installed with casters, it is important that the
installation surface be level due to the probability
of frequent oven repositioning.
We recommend checking the level of the oven
periodically to make certain the floor has not
shifted nor the oven moved.
NOT E : Failure to properly level this oven can
cause improper function and will result in
the uneven baking with products
consisting of semi-liquid batter.
RESTRAINT REQUIREME NTS
—MOBILE EQ UIPMENT
Any appliance that is not furnished with a power
supply cord but that includes a set of casters must
be installed with a tether. Adequate means must
be provided to limit the movement of this
appliance without depending on or transmitting
stress to the electrical conduit. The following
requirements apply:
1. Maximum height of casters is 6" (152mm).
2. Two of the casters must of be the locking type.
Such mobile appliances or appliances on mobile
3.
stands must be installed with the use of a flexible
connector secured to the building structure.
A mounting connector for a restraining device is
located on the lower back flange of the appliance
chassis or on an oven stand, approximately 18"
(457mm) from the floor. A flexible connector is not
supplied by nor is it available from the factory.
PG . 10TH /II I IN S TA L LA T ION /OP E RA T IO N /SE R VI C E MA NU A L
S I T E I N S T A L L A T I O N
W A R N I N G
FAIL UR E TO PROPE R LY INSTALL THE
DRIP TR AY CAN OR WIL L CA US E
MAJOR EQU IP ME NT DAMAGE AND
WILL RE SU LT IN A LEAKAGE
HAZARD TH AT CAN CAUSE
PERSONAL IN JU RY.
D R I P T R AY IN S TA L L AT I O N IN S T R U C T I O N S
D R I P T R AY IN S TA L L AT I O N IN S T R U C T I O N S
STANDARD DRIP PAN*
[BOTTOM OF OVEN INTERIOR • BELOW
SIDE-RACKS]
I N S T A L L A T I O N
HANG DRIP TRAY ON SCREWS
TH /II I IN S TA L LA T ION /OP E RA T IO N /SE R VI C E MA NU A LPG . 11
DRIP
TRAY*
*SEE ALTO-SHAAM PARTS LIST FOR ALTO-SHAAM PART NUMBERS.
I N S T A L L A T I O N
D A N G E R
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
D A N G E R
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in according with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.
D A N G E R
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
E L E C T R I C A L C O N N E C T I O N
The appliance must be installed by a qualified
service technician. The oven must be properly
grounded in accordance with the National
lectrical Code and applicable local codes.
E
Plug the unit into a properly grounded receptacle
ONLY, positioning the unit so that the plug is
easily accessible in case of an emergency. Arcing
will occur when connecting or disconnecting the
unit unless all controls are in the “
FF
O
” position.
Proper receptacle or outlet configuration or
permanent wiring for this unit must be installed
by a licensed electrician in accordance with
applicable local electrical codes.
E L E C T R I C A L - 50 0 - T H / I I I
VOLTA GEPHASECYCL E/HZ AMPS
12016016.01.92N
208-240 (UL)16011.22.70
at 20816010.62.20
at 24016012.22.93
23015012.02.75CE E 7/7
kW
CORD&PLUG
EM A
20A-125
NO CO RD
&
220-230V P LU G
5-20
V
PL UG
P
PL UG
230 V :
To prevent an electrical shock hazard between
the appliance and other appliances or metal
arts in close vicinity, an equalization-bonding
p
stud is provided. An equalization bonding lead
must be connected to this stud and the other
appliances / metal parts to provide sufficient
protection against potential difference.
The terminal is marked with the following
symbol.
NOT E : The appliance must be connected to an
electrical circuit that is protected by an
external GFCI outlet.
E L E C T R I C A L - 75 0 - T H / I I I
VOLTA GEPHASECYCL E/HZ AMPS
208-240 (UL)16015.83.80
at 20816014.63.04
at 24016016.94.05
230150153.0CE E 7/7
E L E C T R I C A L - 10 0 0 - T H / I I I
VOLTA GEPHASECYCL E/ H ZAMP SkWCORD & P LU G
208-240 (UL)16015.83.8
at 20816014.43.0
at 24016016.74.0
23015013.52.7
E L E C T R I C A L - 1 2 0 0 - T H / I I I
VOLTAGEPHASECYCLE/ HZAMPSkWCORD & PLUG
208-240 (UL)160307.2
at 20816028.96.0
at 24016033.38.0
23015028.76.6
PG . 12TH /II I IN S TA L LA T ION /OP E RA T IO N /SE R VI C E MA NU A L
kW
CORD&PLUG
NO CO RD
&
PL UG
220-230V P LU G
NO C ORD
& PL UG
CE E 7/7
220-230V P LU G
NO CORD
& PLUG
NO CORD & PLUG
Loading...