Altinex VA6834FC User Manual

Page 1
INTERFACES
MANUAL PART NUMBER: 400-0039-003 PRODUCT REVISION: 1
VA6834FC
SYSTEM ANALOG INTERFACE
USER’S GUIDE
Page 2
INTERFACES
INTRODUCTION
Superior performance for the right price, backed by solid technical and customer support is what Altinex has to offer.
The product you are holding in your hands is designed using state-of-the-art technology and is superior to anything available on the market. You will find this and our other products reliable, long lasting, and simple to operate.
We are committed to providing our customers with signal management solutions to the most demanding audio-visual installations at very competitive pricing.
We appreciate your selection of our products and are confident that you will join the ranks of our many satisfied customers throughout the world.
This manual covers:
VA6834FC VGA – Pack VA6834FC MAC – Pack VA6834FC SUN/SGI – Pack VA6834FC RGB – Pack VA6834FC Combo – Pack VA6834FC Super – Pack
TABLE OF CONTENTS
Page
PRECAUTIONS / SAFETY WARNINGS ...............2
GENERAL..........................................................2
RACK MOUNT SAFETY GUIDELINES..............2
CLEANING.........................................................2
FCC / CE NOTICE .............................................2
ABOUT YOUR INTERFACE..................................3
TECHNICAL SPECIFICATION..............................3
VA6834FC DESCRIPTION....................................4
COMPUTER VIDEO INPUT (VGA-
COMPATIBLE 15-PIN HD CONNECTOR).........4
LOCAL MONITOR OUTPUT (15-PIN HD
CONNECTOR)...................................................4
MAIN (RGBS/RGBHV) OUTPUTS THROUGH
6 BNC CONNECTORS ......................................4
HORIZONTAL POSITION ADJUSTMENT .........7
HORIZONTAL DELAY REMOVAL .....................7
POWER REQUIREMENTS................................7
MOUNTING CAPABILITY ..................................7
BANDWIDTH .....................................................7
APPLICATION DIAGRAM .....................................8
NSTALLING YOUR INTERFACE ..........................8
OPERATION .........................................................9
SERRATION PULSE SWITCH...........................9
H&V OUT SWITCH ............................................9
I.D. BIT SWITCH................................................9
SYNC ON GREEN OUTPUT SWITCH...............9
TERMINATION SWITCH ...................................9
ACCESSORIES...................................................10
FAQ (FREQUENTLY ASKED QUESTIONS).......11
TROUBLESHOOTING GUIDE ............................12
ALTINEX POLICY ...............................................13
LIMITED WARRANTY......................................13
RETURN POLICY ............................................13
CONTACT INFORMATION ..............................13
1
Page 3
INTERFACES
PRECAUTIONS / SAFETY WARNINGS 1
Please read this manual carefully before using your VA6834FC Interface. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your VA6834FC and to prevent fire and shock hazard. Please read them carefully and heed all warnings.
1.1 GENERAL
Unauthorized personnel shall not open the unit since there are high-voltage components inside.
Qualified Altinex service personnel, or their authorized representatives must perform all service.
1.2. SAFETY GUIDELINES FOR THE RACK­MOUNTING OF THE VA6834FC
Maximum operating ambient temperature is 35 (degrees C).
Never restrict the airflow through the devices’ fan or vents.
When installing equipment into a rack, distribute the units evenly. Otherwise, hazardous conditions may be created by an uneven weight distribution.
Connect the unit to a properly rated supply circuit.
Reliable Earthing (Grounding) of Rack­Mounted Equipment should be maintained.
1.3 INSTALLATION
For best results, place the VA6834FC Interface on a flat, level surface in a dry area away from dust and moisture.
To prevent fire or shock, do not expose this unit to rain or moisture. Do not place the VA6834FC Interface in direct sunlight, near heaters or heat radiating appliances, or near any liquid. Exposure to direct sunlight, smoke, or steam can harm internal components.
Handle the VA6834FC Interface carefully because dropping or jarring can damage internal components.
Do not place heavy objects on top of the VA6834FC. If the VA6834FC is to be mounted
to a table or wall, use only Altinex made mounting accessories, such as brackets (DA1293FC or DA1294FC) and cables for optimum setup.
To turn off the main power, be sure to remove the power cord from the power outlet. The power outlet socket should be installed as near to the equipment as possible, and should be easily accessible.
Do not pull the power cord or any cable that is attached to the VA6834FC Interface.
If the VA6834FC Interface is not used for an extended period, disconnect the power cord from the power outlet.
1.4 CLEANING
Unplug the VA6834FC power cord before cleaning. Clean surfaces with a dry cloth. Never use strong detergents or solvents, such as alcohol or thinner. Do not use a wet cloth or water to clean the unit.
1.5 FCC / CE NOTICE
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
2
Page 4
INTERFACES
Any changes or modifications to the unit not expressly approved by Altinex, Inc. could void the user’s authority to operate the equipment.
ABOUT YOUR INTERFACE 2
There are many types of computers and computer video cards on the market today. There are also numerous data monitors and large screen data projectors. When a computer image is displayed on a large screen data projector or on a large screen monitor, it often becomes clear that some computers are not always compatible with certain display devices. The VA6834FC is a computer video interface designed to resolve this incompatibility.
The VA6834FC is a dual output computer video interface. It is designed to interface a single VGA/ SVGA/XGA/UXGA/MAC/SUN or SGI computer video source to two scan-rate compatible presentation monitors or data projectors.
It is important to understand the general capabilities of interfaces. Interfaces do not change the scan-rate or the resolution of the video signal. An interface simply converts a computer video signal to a pre-selected analog format.
The VA6834FC is a state-of-the art piece of equipment with an exceptional combination of compact size, advanced features and very competitive pricing.
TECHNICAL SPECIFICATIONS 3
FEATURES/DESCRIPTION VA6834FC GENERAL Inputs
Computer Video Input Connector
Outputs
Local Monitor Connector 15-pin HD Female Main Video Connector 2 sets of 6-BNC F
Compatibility
15-pin HD Female
Local Monitor Output +
2 Main Video Outputs
VGA/SVGA/XGA/ UXGA, Apple/MACII/ Quadra/G3, Sun/SGI
Table 1. VA6843FC General
1
Workstations
MECHANICAL VA6834FC
Width (inches) 8.50in Height (inches) 1.75in Depth (inches) 4.93in. Weight (pounds) 2.0lbs. Ship Weight (pounds) 2.8lbs. Material 0.1" Aluminum Finish Gray Faceplate Lexan T° Operating 10°C-35°C T° Maximum 50°C Humidity l MTBF (calculations) 40,000 hrs
90% non-condensing
Table 2. VA6834FC Mechanical
ELECTRICAL VA6834FC Input Video Signal
Analog Signal 0.3 to 1.2 volt p-p Impedance 75 Ohms Rise/Fall Time (ns) 0.9
Input Sync Signal
Horizontal, Vertical, & C- TTL(+/-) Sync Sync on Green -0.3V Impedance 0.3 k Ohms
Output Video Signals
Analog Signal 0.77 V p-p Impedance 75 Ohms Rise/Fall Time (ns) 1.2
Output Sync Signal
Composite Sync TTL(+/-) Sync on Green -0.3V Impedance 22 Ohms
Frequency Compatibility
Minimum Video Bandwidth 350 MHz Typical Video Bandwidth 425 MHz Horizontal 15-130 kHz Vertical 25-180 Hz
Horizontal Position Range Cross-talk Power
Internal Power Supply 90-140V/200-240V
Power Consumption
20 %
39dB @ 100MHz
Table 3. VA6834FC Electrical
3
Page 5
INTERFACES
VA6834FC DESCRIPTION 4
The VA6834FC has two key functions. Its first function is to buffer the signal and insure that it is strong enough to travel a distance of 100 ft or longer through a coaxial cable. The second function is to process the sync and to convert it into a format that is acceptable to most displays.
4.1 COMPUTER VIDEO INPUT (VGA­COMPATIBLE HD 15-PIN CONNECTOR).
The HD 15-pin connector input allows the connection of a computer source to the interface using Altinex input cables, which are available for a variety of popular computers and graphics cards on the market. These include VGA, MAC, SUN, and SGI type video output connectors with the proper cables. The VA6834FC input is compatible with standard VGA cables.
PIN No.
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15
Table 4. VA6834FC Input pin-out
4.2 LOCAL MONITOR OUTPUT (HD 15-PIN CONNECTOR)
The HD 15-Pin connector output is used to connect the local monitor to the interface. This is a fully buffered output, eliminating reflections often caused by “Y” type monitor breakout cables. There is no need to terminate the unused output. The termination switch on the VA6834FC affects only the terminations of the computer video input. The output is VGA compatible, but can also be used to feed other
INPUT SIGNALS ON HD 15-PIN FEMALE
CONNECTOR
Red Video Green Video Blue Video ID Bit (Grounded when ID Bit switch is ON) Ground Ground Ground Ground No connection No connection ID Bit ID Bit Horizontal Sync/Composite Sync Vertical Sync No connection
types of local monitors using designated Altinex adapter cables such as VGA, MAC, SUN, SGI or RGB.
PIN No.
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15
LOCAL MONITOR OUTPUT SIGNALS ON
15-PIN HD FEMALE CONNECTOR
Red Video Green Video Blue Video ID Bit (Grounded when ID Bit switch is ON) Ground Ground Ground Ground Composite Sync No connection ID Bit ID Bit Horizontal Sync Vertical Sync No connection
Table 5. Local Monitor Output pin-out
4.3 MAIN (RGBS/RGBHV) OUTPUTS THROUGH 6 BNC CONNECTORS
BNC connectors offer a reliable connection for high-resolution video signals, and they facilitate easy cable maintenance in the field. The VA6834FC offers two main outputs with six BNC connectors for each output. By selecting the appropriate connectors, these outputs can provide RGSB, RGBHV, or RGBS output signals.
For a RGsB type signal the “Sync on Green” dip switch must be set to the ON position.
For an RGBHV type signal, you may either connect cables to horizontal or vertical BNC connectors or you may connect the horizontal channel to the composite sync connector by turning the HV OUTPUT switch to the ON position. For a RGBS type signal output, the cables should be connected to a composite sync signal. With these connectors the VA6834FC can be connected to compatible data projectors using 3 coax, 4 coax, or 5 coax cables.
4
Page 6
INTERFACES
5
Page 7
INTERFACES
6
Page 8
INTERFACES
CONNECTOR MAIN DUAL OUTPUT (6-BNC
FEMALE)
Red Green Blue Sync Hor. Vert.
Red Video Green Video Blue Video Composite Sync/ Horizontal Horizontal Sync Vertical Sync
Table 3. VA6834FC dual (6 BNC) Output pin-out
4.4 HORIZONTAL POSITION ADJUSTMENT
Most monitors and projectors have the ability to adjust the horizontal position of the image, but sometimes it is helpful to be able to control this feature at the interface. This control is especially useful when multiple computers are switched to a single display and the horizontal positions from each computer are slightly different.
By keeping the VA6834FC’s horizontal position control dial located in the center position, the image on the display should be adjusted using the monitor or projector control. If it is necessary, adjust the horizontal position of the image with the VA6834FC’s horizontal position control dial.
To turn off the horizontal position control, turn the adjustment dial fully to the right until a “clicking sound is heard.
4.5 HORIZONTAL DELAY REMOVAL
The VA6834FC offers the ability to by-pass horizontal delay. This may be necessary when interfacing with projectors or monitors with sensitive sync inputs, particularly with LCD type projectors. By turning the horizontal position adjustment dial fully to the right, the control will “click” into a locked position. In this position, the VA6834FC outputs the same sync type as that which is fed into it from the source. In this setting, the VA6834FC will not provide horizontal positioning. Horizontal position adjustment must be made at the display.
4.6 POWER REQUIREMENTS
The VA6834FC may be used with either 120V or 220V throughout the world for ease of use. Always make sure that the fuse box window above the power input connector displays the proper voltage. To change the setting, unplug the VA6834FC, and squeeze the clips on either side of the fuse box. Pull out the fuse holder and turn it 180 degrees, resetting it with the proper voltage shown through the window. Re-insert the fuse box making sure that the side clips of the fuse box lock securely into place.
4.7 MOUNTING CAPABILITY
The VA6834FC can be easily mounted into an equipment rack. Four mounting holes are provided on each side of the unit. To mount a single unit, use Altinex 19”-1U Rack Mount Ears (part # DA1294FC). To mount two units in tandem, use an Altinex 19”-1U Rack Mount Shelf (part # DA1293FC). For mounts under the table, optional brackets, such as theTM1271,
TM1272, TM1273, or TM1274 can be used.
4.8 BANDWIDTH
The typical bandwidth of the VA6834FC is 425 MHz. The minimum bandwidth is 350 MHz. This exceptionally high bandwidth allows the passing of the third harmonics of the video signal, thus maintaining the highest quality of the input signal.
7
Page 9
APPLICATION DIAGRAM 5
INTERFACES
INSTALLING YOUR INTERFACE 6
Step 1. Please attach the Interface on the rack
using the provided rack mount hardware. The Interface can also be attached on top or under furniture using the optional TM Series Altinex brackets.
Step 2. Before you plug in the power cord to the
unit, please verify that the voltage rating of 110V/220V which is located on the FUSE CLIP at the rear of the unit is the same as the power outlet. (Refer to section 4-6 for changing voltage)
Step 3. Connect one end of the input cable
included with the Interface unit to the video output connector of your computer and other end to the computer input HD­15 port of the VA6834FC.
Step 4. If needed, connect the local monitor
output HD-15 connector of the VA6834FC to the local monitor using the appropriate Altinex Local Monitor cables. It is not necessary to terminate this output with a termination plug if a local monitor is not being used.
Step 5. Connect one end of a BNC cable to
output 1 or 2 of the VA6834FC. Connect the other end to the RGB input on the projector or monitor. Usually either a 4 BNC or 5 BNC coaxial cable is used, depending on whether display devices require Composite SYNC or H&V SYNC signals.
Step 6. Make sure that the dip- switches are set
properly. For the desired sync output format, refer to section 7.
Step 7. It is recommended that if the Interface
horizontal position control is centered (turned OFF), the horizontal position of the image should be adjusted using the control provided by the monitor or projector. If still required, the image can be adjusted using the horizontal position control dial located on the front of the
VA6834FC.
CONGRATULATIONS! YOU ARE DONE.
If you experience any problems, please call
1-800-258-4623 or 1-714-990-2300 for
international calls.
8
Page 10
INTERFACES
OPERATION 7
The settings of the VA6834FC Interface can be adjusted using the dip-switches in Table 4. There are no other adjustments necessary to operate the unit. The VA6834FC will operate successfully as long as cables are attached properly and technical specifications are followed.
DIP SWITCH OFF ON
Serration X HV Output X Sync on Green X Termination X ID Bit X Not Used X
Table 6. Dip switches default setting
7.1 SERRATION PULSE SWITCH
Certain monitors and projectors will exhibit better stability when the serration pulse switch is ON. This switch is seldom used and in most circumstances should be turned OFF.
7.2 H&V OUT SWITCH
When the composite sync channel is used and RGBS format is desired from the VA6834FC, the H & V OUT switch should be turned off. When this switch is turned on, the sync. The connector will output horizontal sync, but not composite sync. The horizontal sync can be connected to the sync connector and the vertical sync signal is connected to the vertical connector using the H & V OUT switch in the ON position.
the boot up stage of the computer. If your computer does not output video, place the I.D. Bit switch in the ON position and reboot the computer. When in the OFF position, the ID Bit will be passed through the Local Monitor Output port.
7.4 SYNC ON GREEN OUTPUT SWITCH
In some systems the ability of the VA6834FC to output Sync on Green can be a very helpful feature. It is important to know that the VA6834FC will not separate the sync signal from the green signal if the input is RGsB. It simply amplifies the composite sync signal and passes it through. The VA6834FC will combine the sync signal and the green channel to output a RGsB signal when the SYNC ON GREEN dip-switch is in the ON position even if the input is in RGBS or RGBHV format. If the desired output is RGBS or RGBHV, then leave the SYNC ON GREEN dipswitch in the OFF position.
7.5 TERMINATION SWITCH
When the built-in termination switch is set to the ON position, the input of the interface will be terminated. As a rule, the termination switch should be ON. This switch does not affect the termination of any output signal. The termination switch should be left in the OFF position if a “Y” cable is used at the local monitor output connector.
7.3 I.D. BIT SWITCH
Many computers use ID Bits or Sense Pins to recognize the connection of a monitor to its video output port. Often, these ID Bits will even allow the computer to recognize the type of monitor connected in terms of its scan rate compatibility. When the I.D. Bit switch is in the ON position, the VA6834FC allows the main ID Bit (pin 4 on the input connector) to be connected to the ground signal. This is used primarily when interfacing to laptop computers to imitate the presence of a local monitor. Typically, this recognition will take place during
9
Page 11
INTERFACES
ACCESSORIES 8
Model No. Description
RACK MOUNT ACCESSORIES
DA1293SX Rack/Wall Shelf fits two VA6834FC
units side by side
DA1294SX
TM1271 TM1272
TM1273
Model No. Description TM1274
MS8121CA MAC Output cable for VA6834FC MS8122CA MAC Input cable for VA6834FC
MS8123CA MS8124CA SUN/SGI Input cable for VA6834FC
MS8125CA VGA Output cable for VA6834FC MS8126CA VGA Input cable for VA6834FC MS8129CA RGB Output cable for VA6834FC
CB4103MR CB4106MR CB4112MR CB4125MR CB4150MR CB4175MR CB41100MR
CB41150MR
CB4203MR CB4206MR CB4212MR CB4225MR
CB4250MR
CB4275MR
Rack/Wall mount ears for single
VA6834FC TABLE MOUNT BRACKETS
1U High, ½ Rack-Wide 1U High, ½ Rack-Wide with 15-pin
HD connector plate 1U High, ½ Rack-Wide with snap-in connectors
1U High, ½ Rack-Wide with snap-in & POWER connectors
INTERFACE CABLES
SUN/SGI Output cable for
VA6834FC
4-BNC TO 4-BNC COAXIAL CABLE
3 ft, 4-BNC to 4-BNC coaxial cable 6 ft, 4-BNC to 4-BNC coaxial cable 12 ft, 4-BNC to 4-BNC coaxial cable 25 ft, 4-BNC to 4-BNC coaxial cable 50 ft, 4-BNC to 4-BNC coaxial cable 75 ft, 4-BNC to 4-BNC coaxial cable 100 ft, 4-BNC to 4-BNC coaxial
cable 150 ft, 4-BNC to 4-BNC coaxial cable
5-BNC TO 5-BNC COAXIAL CABLE
3 ft, 5-BNC to 5-BNC coaxial cable 6 ft, 5-BNC to 5-BNC coaxial cable 12 ft, 5-BNC to 5-BNC coaxial cable 25 ft, 5-BNC to 5-BNC coaxial cable 50 ft, 5-BNC to 5-BNC coaxial cable 75 ft, 5-BNC to 5-BNC coaxial cable
CB42100MR
CB42150MR
CB4400MR
CB4406MR CB4412MR CB4425MR
CB4475MR CB44100MR CB44150MR
CB5000PL
CB5000PL­5BM00035BM CB5000PL­5BM00065BM CB5000PL­5BM00125BM CB5000PL­5BM00255BM CB5000PL­5BM00505BM CB5000PL­5BM00755BM CB5000PL­5BM01005BM CB5000PL­5BM01505BM CB5000PL­5BM02005BM CB5000PL­5BM02505BM
CB5100PL
CB5100PL­5BM00035BM CB5100PL­5BM00065BM CB5100PL­5BM00125BM CB5100PL­5BM00255BM CB5100PL­5BM00505BM CB5100PL­5BM00755BM
100 ft, 5-BNC to 5-BNC coaxial cable 150 ft, 5-BNC to 5-BNC coaxial cable
6 ft, 5-BNC to 5-BNC coaxial 12 ft, 5-BNC to 5-BNC coaxial 25 ft, 5-BNC to 5-BNC coaxial 50 ft, 5-BNC to 5-BNC coaxial 75 ft, 5-BNC to 5-BNC coaxial 100 ft, 5-BNC to 5-BNC coaxial 150 ft, 5-BNC to 5-BNC coaxial
3 ft, 5-BNC M to 5-BNC M 6 ft, 5-BNC M to 5-BNC M 12 ft, 5-BNC M to 5-BNC M 25 ft, 5-BNC M to 5-BNC M 50 ft, 5-BNC M to 5-BNC M 75 ft, 5-BNC M to 5-BNC M 100 ft, 5-BNC M to 5-BNC M 150 ft, 5-BNC M to 5-BNC M 200 ft, 5-BNC M to 5-BNC M 250 ft, 5-BNC M to 5-BNC M
3 ft, 5-BNC M to 5-BNC M 6 ft, 5-BNC M to 5-BNC M 12 ft, 5-BNC M to 5-BNC M 25 ft, 5-BNC M to 5-BNC M 50 ft, 5-BNC M to 5-BNC M 75 ft, 5-BNC M to 5-BNC M
10
Page 12
INTERFACES
CB5100PL­5BM01005BM CB5100PL­5BM01505BM CB5100PL­5BM02005BM CB5100PL­5BM02505BM
All MS81 series cables listed on the previous page are 3 ft. long. These are available in 6 ft. and 12 ft. lengths. Please call 1-714-990-2300 for a wider selection of cables.
100 ft, 5-BNC M to 5-BNC M 150 ft, 5-BNC M to 5-BNC M 200 ft, 5-BNC M to 5-BNC M 250 ft, 5-BNC M to 5-BNC M
FAQ (FREQUENTLY ASKED QUESTIONS) 9
No: Question Answer 1 Why does
the termination switch have to be ON?
2 When and
why should I use the Horizontal Position Control dial?
3 What dip-
switch do I set to obtain composite SYNC output?
4 When and
why would I use the sync on green dip­switch, although the unit does not
The termination switch should be ON if a local monitor is connected through a straight cable. It will be OFF only if a monitor breakout cable is used at the local monitor output connector. The Horizontal Position Control dial enables or disables the control of the horizontal position of the image. First, adjust the horizontal position using the monitor or projector’s control. Then use the horizontal Position Control of the VA6834FC, if needed. If the desired output signal is composite sync, then turn OFF the H & V OUTPUT Dip-switch and connect only 4 wires (RGBS) to the red, green, blue and sync connectors.
The VA6834FC does not separate the sync signal from green. If the desired output is in RGsB format, turn the sync on green dip-switch to the ON position. The VA6834FC combines sync on green if the dip-switch is in the ON position.
separate sync from green?
5 When do I
use the H & V OUT dip-switch?
6 What is a
Common Computer Video Card pin-out?
If the desired output is in RGBHV format, turn ON the H & V OUT dip-switch. If the H & V OUT dip-switch is OFF, then the output signal may have composite sync present on the horizontal sync connector. See table 5 for pin-outs for common computer video cards that can be used with the
VA6834FC.
11
Page 13
INTERFACES
PIN No.
A1 A2 A3
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15
Table 7. Common Computer Video Cards pin-out.
MAC VGA SUN
n/a n/a Red n/a n/a Green n/a n/a Blue Red Gnd Red N/C Red Green N/C C.Sync Blue Sense ID Bit 01 ID Bit Sense Rtn Green N/C C. Sync Sens Green Gnd. Red Rtn. N/C ID Bit 02 Green Rtn. N/C N/C Blue Rtn. N/C Blue N/C N/C ID Bit 03 Gnd N/C C/V Gnd. ID Bit V. Sync ID Bit Blue Gnd. H. Sync. H. Gnd V. Sync H. Sync N/C
TROUBLESHOOTING GUIDE 10
1. The power, LED should be ON when the correct voltage is applied to Interface.
2. The Termination dipswitch should be in the ON position if no Y cable (breakout) is used on the input.
3. Make sure that the cables have the correct pin-outs and the connection and quality of the cables are good.
4. Make sure that the source and display are scan-rate compatible. The projector should support an appropriate signal format (RGsB, RGBS or RGBHV). Connect the projector directly to a computer with a shorter cable to verify the compatibility of the display and the source.
5. If you are using output RGBS or RGsB then the HV Output dip-switch is in the OFF position and the composite sync signal is taken from the sync connector. If the display needs an RGBHV signal then the HV Output dip-switch should be ON if sync and vertical connectors are used.
6. If the desired output is RGsB then the Sync on Green dipswitch should be ON.
12
Page 14
INTERFACES
ALTINEX POLICY 11
11.1 LIMITED WARRANTY
Altinex warrants that its products and cables are free from defects in materials under normal use and service. This warranty is limited to repairing at company’s factory any part or parts of the product, which upon company’s examination shall disclose to be, thus defective. Products considered defective should be returned to company with transportation charges pre-paid within 2 years (90 days for cables) from date of shipment to the purchaser. The warranty is expressly instead of all other warranties expressed or implied. Altinex neither assumes nor authorizes any other person to assume for it any other liability in connection with the sale of the products. This warranty shall not apply to any product that shall have been repaired or altered outside of company’s factory in any way so as, in its judgment, to affect its stability or reliability, or that has been subject to misuse, negligence or accident.
If your product is out of warranty and needs service, contact the Altinex Sales Department for an RMA (Return Material Authorization). Products returned without an RMA number may experience a delay in service. The service charges will be quoted to you before the actual repairs are done.
11.3 CONTACT INFORMATION
Sales Department
Phone: 714-990-2300 Fax: 714-990-3303
Accounting Department
Phone: 714-990-6088 Fax: 714-990-5778
11.2 RETURN POLICY
It is very important to Altinex that you receive the product that you have ordered and that this product fulfills your need. In the unlikely event, that an Altinex product needs to be returned please follow the policies below:
Altinex will accept product returns for a period of 30 days from authorized Altinex dealers. Products must be returned in an unopened package.
If a product has been opened, the restocking fees will apply. For the restocking fee amount, please contact an Altinex Sales Representative.
If the product is in your possession for more than 30 days, the restocking fees will apply.
Altinex will not accept any returns on cables or custom products.
If your product is in warranty and needs service, contact the Altinex Sales Department for an RMA (Return Material Authorization). Products returned without an RMA number may experience a delay in service.
13