1. Precautions and Safety Warnings
Please read this manual carefully before using your UT-Series Interconnect. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your UT-Series Interconnect and to prevent fire and shock hazards. Please read them carefully and heed all warnings.
1.1 General
There are no user serviceable parts inside. Qualified ALTINEX service
personnel must perform all service on the UT-Series.
1.2 Handling
To prevent fire or shock, do not expose this unit to water or moisture.
Do not place the UT-Series in direct sunlight, near heaters, or heat-radiating appliances, or near any liquid. Exposure to direct sunlight, smoke, or steam can harm internal components.
Handle the unit carefully. Dropping or jarring can cause damage. Do not pull any cables that are attached to the UT-Series. Do not place heavy objects on top of the UT-Series.
2. Installation Procedures
The UT Series can be installed horizontally or vertically as shown. Typically, units are installed under a tabletop, but in some cases, it may be desirable to install a unit inside a desk opening, or on the back of a desk or podium.
Step 1. Locate the best position for the UT Interconnect, but do NOT mount it to the surface until cables are ready.
Step 2. Prepare the mating cables using high-quality cables for best results and durability. Make sure the cables are long
enough to allow for a service-loop and so the cables can be neatly routed beneath the table to their destinations.
Step 3. Prepare network cables using the CAT-6 (RJ-45) connectors provided with the unit.* The connectors are
high-quality snap-in connectors and do not require any tools for installing them into the UT interconnect.
Note: Connectors are provided but do not include cables. ALTINEX
recommends a telecommunications contractor wire the network connectors and verify operation before installing the UT interconnect.
Step 4. Secure the unit under the table using the metal screws provided with the unit.
Step 5. Make any necessary connections to the snap-in connectors.
Step 6. Use cable-ties to secure the cables to the mounting shelf.
Insert the ties through the holes on the bottom of the unit.
Step 7. Use the cable clamps provided to secure the cables to the bottom of the table/desk.
* Not all units include network connections. Please visit our website: www.altinex.com
for information related to the pin out of the cables.
3. Limited Warranty/Return Policies
Please see the ALTINEX website at www.altinex.com for details on warranty and return policies.
1.3 Cleaning
Unplug the UT-Series before cleaning. Clean only with a dry cloth. Never use strong detergents or solvents such
as alcohol or thinner. Do not use a wet cloth or water to clean the unit. Do not open the unit to clean.
1.4 FCC Notice
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for
a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with instructions found herein, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Any changes or modifications to the unit not expressly approved by
ALTINEX, Inc. could void the user’s authority to operate the equipment.
Installation Options
Table Top (Side View)
Inside Desk (Side View)
Back of Desk/Podium (Top View)
LEFT
UT240-278 Audio Wiring
SHIELD
RIGHT
400-0491-006
1
UT Series User’s Guide
4. Technical Specifications
Specifications are subject to change. See www.altinex.com for up-to-date information.
Features/Description UT240-300 Series
Pass-Through AC Power
Audio, Stereo Cable Audio, Stereo TB 3.5 mm F to Term Block
Audio, Stereo RCA RCA bulkhead F-F Network (CAT-6) Snap-in RJ-45 connector (no cable) Modem/phone Snap-in RJ-11 connector (no cable) Video, Analog 15-pin HD bulkhead, F-F Video, Digital 19-pin HDMI bulkhead, F-F Video BNC bulkhead F-F Communication USB Type A F-F Models (options)
CAT-6 (RJ-45) F (1) Modem (RJ-11) F (1) AC receptacle (1)
UT240-278 (U.S.)
UT240-311 (U.S.)
UT240-313 (U.S.)
UT240-310 (U.S.) UT240-411 (EUR) UT240-451 (ENG) UT240-511 (AUS) UT240-551 (UNIV) UT240-312 (U.S.) UT240-410 (EUR) UT240-450 (ENG) UT240-510 (AUS) UT240-550 (UNIV)
Continued…
15-pin HD F-F (1)
3.5mm F to Term Block (1) BNC F-F (1) RCA F-F (2) CAT-6 (RJ-45) F (4) AC receptacle (2) 15-pin HD F-F (2) 24-pin DVI F-F (2)
3.5mm F-F (2) CAT-6 (RJ-45) F (4) AC receptacle (2)
15-pin HD F-F (2) CAT-6 (RJ-45) F (4)
3.5mm F-F (2) AC receptacle (2)
CAT-6 (RJ-45) F (4) AC receptacle (4) 15A Circuit Breaker (1)
(front to back)
NEMA Receptacle to plug
9-10 ft (2.7-3.0 m) cord
3.5 mm F-F
8 in (200 mm) cable
UT240-121S (U.S.)
UT240-125S (U.S.)
UT240-128S (U.S.)
UT240-325S (U.S.)
UT240-328S (U.S.)
Agency Approvals UL/CUL Listed
(File E254082) Accessories Included
Hardware Mounting hardware
Table 1. UT240-300 Series General
Mechanical UT240-300 Series
Dimensions See Application Diagrams Maximum Shipping Weight* 3.5 lb. (1.6 kg) T Operating [T Maximum] 10C-35C [50C] Humidity
Table 2. UT Series Mechanical
Electrical UT240-300 Series
Pass-Through Signals Pass-Through AC
Table 3. UT Series Electrical
CAT-6 (RJ-45) F (1) Modem (RJ-11) F (1) AC Power (1) 15-pin HD F-F (1)
3.5mm F to Term Block (1) CAT-6 (RJ-45) F (1) USB Type A F-F (1) AC Power (1) 15-pin HD F-F (1)
3.5mm F to Term Block (1) CAT-6 (RJ-45) F (1) Digital Vid (HDMI) F-F (1) AC Power (1) 15-pin HD F-F (1)
3.5mm F to Term Block (1) CAT-6 (RJ-45) F (2) Digital Vid (HDMI) F-F (2) AC Power (2)
3.5 mm Stereo Cable (2) CAT-6 (RJ-45) F (2) Digital Vid (HDMI) F-F (1) AC Power (2) 15-pin HD F-F (1)
3.5 mm Stereo Cable (2)
UT240-278/-310/-311/-312/-313
90 non-condensing
All standard audio, video, network,
and modem signals are acceptable.
12 A, 1440 W max.
(total through all receptacles)
* Shipping weights range from 2.1 lb. for the UT240-278 up to 3.5 lb. for the UT240-550 (1.0 kg to 1.6 kg).
Packaging material is approximately 0.5 lb. or 0.23 kg.
400-0491-006
2
UT Series User’s Guide
5. About Your UT Interconnect
The ALTINEX UT-Series of Under-the-Table AV Interconnects provide a wide variety of options for routing computer audiovisual signals, network connections, and AC power. Under-the-table options are ideal for situations where it is too expensive or impractical to install the routing interface directly into the furniture.
The UT240-300 Series are available in both U.S. and international versions. U.S. versions provide standard NEMA 5-15R receptacles; international units include AC receptacles for Europe, England, and Australia. The UT240-550 and UT240-551 include universal AC receptacles that accept various types of AC plugs. U.S. and international models UT240-312, UT240-410, UT240-450, UT240-510, and UT240-550 also include a push-to-reset 15A circuit breaker.
Each unit comes standard with 1 or more AC receptacles and 1 or more RJ-45 connectors. The UT240s connect to standard AC power outlets through a single 9-10 ft (2.7 to 3.0 m) power cord that is permanently attached to the unit. The CAT-6 (RJ-45) connectors are snap-in style connectors that attach to a support bracket inside the faceplate. The connectors must be "snapped" out of the bracket, wired to the CAT-5/6 cable, and then "snapped" back.
The UT240-300 Series units with audio inputs have 3.5 mm female inputs on the front of the unit and 3.5 mm female inputs on the back via an 8 in (200 mm) cable. The audio receiving devices attach to the cable on the back of the unit. The Under-the-Table units with model numbers ending in 121S, 125S, 128S, and 278 have a 3.5 mm female input on the front and a terminal block connector with captive screws on the back of the unit.
Units with video connectors have female-to-female bulkhead connectors for HDMI, 15-pin HD, and 24-pin DVI types. The video receiving devices attach to the bulkhead connectors accessible on the back of the unit.
UT240-313 shown here.
UT240-310
UT240-411 Europe UT240-511 Australia
UT240-451 England UT240-551 Universal
AC (2) Net (4)
UT240-312 UT240-313
UT240-410 Europe UT240-450 England UT240-510 Australia
* The circuit breaker is located on the inside of the left-hand side
of each unit as view ed from the front. (see Diagram 14)
UT240-550 Universal
VGA (2) Audio (2)
AC (4) Net (4) Circuit Breaker (1)
Phone/modem (1)
AC (1)
Net (1)
UT240-278
RCA (2)
VGA (1)
Audio (1)
BNC (1)
UT240-311
AC (2) Net (4)
AC (2) Net (4) VGA (2)
DVI-I (2) Audio (2)
400-0491-006
3
UT Series User’s Guide
AC (1) Blank (3) Phone/Modem (2)
AC (1) Blank (3) Phone/Modem (1)
AC (1) Audio (1) Blank (3)
UT240-121S
UT240-125S
UT240-128S
VGA (1)
HDMI (1)
USB Type A (1)
Audio (1)
HDMI (1)
Phone/Modem (1)
VGA (1)
AC (2) Net (2) Blank (2)
AC (2) Net (2) Blank (2)
UT240-325S
UT240-328S
HDMI (2) Audio (2)
HDMI (1) VGA (1) Audio (2)
400-0491-006
4
UT Series User’s Guide
6. Application Diagrams
Diagram 1: Typical Setup
UT240-310 Shown Above
UT240 Series
400-0491-006
5
UT Series User’s Guide
Diagram 2: UT240-310/UT240-325S/UT240-328S U.S./Canada
2.300"
[58mm]
Diagram 3: UT240-311 U.S./Canada
2.300"
[58mm]
9.400"
[239mm]
10.400"
[264mm]
1.850"
[47mm]
6.636"
[169mm]
3.095"
[79mm]
7.636"
[194mm]
1.850"
[47mm]
3.095"
[79mm]
400-0491-006
6
UT Series User’s Guide
Diagram 4: UT240-312 U.S./Canada
2.300"
[58mm]
Diagram 5: UT240-313 U.S./Canada
2.300"
[58mm]
9.400"
[239mm]
10.400"
[264mm]
10.596" [269mm]
11.596"
[295mm]
1.850" [47mm]
3.095"
[79mm]
3.095"
[79mm]
400-0491-006
7
UT Series User’s Guide
Diagram 6: UT240-410 Europe
2.300"
[58mm]
Diagram 7: UT240-411 Europe
2.300"
[58mm]
13.294"
[338mm]
14.294"
[363mm]
11.400"
[290mm]
12.400"
[315mm]
2.450"
[62mm]
3.095"
[79mm]
2.450"
[62mm]
3.095"
[79mm]
400-0491-006
8
UT Series User’s Guide
Diagram 8: UT240-450 England
2.300"
[58mm]
Diagram 9: UT240-451 England
2.300"
[58mm]
13.294"
[338mm]
14.294"
[363mm]
11.400"
[290mm]
12.400"
[315mm]
2.450"
[62mm]
3.095"
[79mm]
2.450"
[62mm]
3.095"
[79mm]
400-0491-006
9
UT Series User’s Guide
Diagram 10: UT240-510 Australia
13.294"
[338mm]
2.300"
[58mm]
14.294"
[363mm]
Diagram 11: UT240-511 Australia
11.400"
[290mm]
2.300"
[58mm]
12.400"
[315mm]
400-0491-006
10
2.450"
[62mm]
3.095"
[79mm]
2.450"
[62mm]
3.095"
[79mm]
UT Series User’s Guide
Diagram 12: UT240-550 Universal
2.300"
[58mm]
Diagram 13: UT240-551 Universal
2.300"
[58mm]
13.294"
[338mm]
14.294"
[363mm]
11.400"
[290mm]
12.400"
[315mm]
2.450"
[62mm]
3.095"
[79mm]
2.450"
[62mm]
3.095"
[79mm]
400-0491-006
11
UT Series User’s Guide
Diagram 14: UT240-278 US/UT240-121S/UT240-125S/UT240-128S US/Canada
1.600"
[40.6 mm]
0.500"
[12.7 mm]
7.844"
[199.2 mm]
6.844"
[173.8 mm]
7.294"
[185.3 mm]
0.500"
[12.7 mm]
1.844"
[46.8 mm]
0.500"
[12.7 mm]
2.396"
[60.9 mm]
2.446"
[62.1 mm]
400-0491-006
12
UT Series User’s Guide
Diagram 15: Circuit Breaker
Model numbers UT240-312, UT240-410, UT240-450, UT240-510, and UT240-550 include a 15A circuit breaker. The circuit breaker is located in the same location for each model. The UT240-312 is shown here.
CIRCUIT BREAKER
Push to reset.
400-0491-006
13
UT Series User’s Guide
Diagram 16: Audio Wiring (terminal block)
LEFT
3.5 mm
AUDIO INPUT
SHIELD
RIGHT
400-0491-006
14
UT Series User’s Guide
7. Operation
The UT-Series requires no adjustments for performance. Once set-up, the UT-Series will work trouble-free without user intervention.
7.1 Circuit Breaker Reset
The UT240-312, UT240-410, UT240-450, UT240-510, and UT240-550 include a push-to-reset 15A circuit breaker. The circuit breaker is accessible from the left-hand side of the unit as viewed from the front. In the event the circuit breaker is tripped, do the following:
Disconnect all AC devices from the UT240 Turn off the power switch of each AC device Push the circuit breaker reset button back in Reconnect the AC devices One at a time, turn on the AC devices
WARNING
If the circuit breaker trips again, find the device that is drawing excessive current. Check the ratings for each of the devices connected to the UT240. If a device requires a significant amount of power, it should be plugged into its own supply circuit.
8. Troubleshooting Guide
We have carefully tested and found no problems in the supplied UT-Series; however, if you experience any problems or have questions, call ALTINEX at (714) 990-2300.